TYROLIT
Hydrostress AG
Page 26
Wall saw WSE811
Switching off the wall saw
Switching off the wall saw
Proceed as follows:
X
Press the start switch (1) on the remote controller to the 0 position.
X
Turn off the cooling water, switch (2) water 0/1.
X
Switch off the wall saw WSE811
using the main switch (3).
X
Switch off the WSE811
wall saw using the main switch on the wall saw head.
Caution
Frost can damage the wall saw
WSE811
!
X
Blow out any water if there is a risk of frost (see chapter 4.9, Blowing out the water).
Only stop the wall saw WSE811
using the EMERGENCY STOP function in an emergency.
Blowing out the water
9
The main switch is set to
OFF
X
Disconnect the mains plug.
X
Disconnect all water lines.
X
Connect the purge pump to the water nipple.
X
Blow out water until all of the cooling water has been removed (see chapter 5.2).
X
Remove the pump.
4.8
4.9