TYROLIT Hydrostress WSE1217 Operating Instructions Manual Download Page 16

TYROLIT

 

Hydrostress AG

Page 16

Wall saw WSE1217



Saw blades

Saw blades

Parameter

Value

Saw blade max.

Ø 1,200 mm

Fully detachable saw blade

Ø 800 mm

Blade holder

Ø 60 mm

Blade flange mounting at wall saw

Quick-release flange ST

Saw blade fixing on blade flange
(also for flush cuts)

6 countersunk head screws
reference circle 130 mm

Blade cover mounting on blade flange

2 hexagonal bolts

Cutting depth

Ø 650 mm

230 mm

Ø 800 mm

320 mm

(Ø 900 mm)

(350 mm)

Ø 1,000 mm

420 mm

Ø 1,200 mm

520 mm

Lubricants, fluids and sealants

Lubricants, fluids and sealants

Parameter

Value

Gear oil (swivel arm)

Klüber GEM 4-150 N (TYROLIT No. 10981362)

Lubricating grease (lock unit)

Penetration

265 to 295

NLGI

2

Lubricating grease (swivel gear)

Penetration

400 to 430

NLGI

00

Connectable control units

The wall saw must only be operated with the coordinated control units from TYROLIT Hydros-

tress.

Control unit

Parameter

Type

Control unit

WSE1217



     (Ø650 / Ø800 / Ø1,000 / Ø1,200)

Water connection

Parameter

Value

Pressure

min. 2 bar / max. 6 bar

Quantity

At least 4 l/min

Max. temperature

25 °C

5.8

5.9

5.10

Summary of Contents for WSE1217

Page 1: ...Operating Instructions Wall saw WSE1217 Index 000 Original operating instructions 10991490 en 01 09 2016...

Page 2: ...nuine TYROLIT Hy drostress replacement parts can guarantee quality and interchangeability If maintenance work is neglected or carried out inexpertly we will be unable to honour our warranty obligation...

Page 3: ...ty Manual System Handbook may result in serious injury or even death X X Please ensure that the Safety Manual System Description for Wall Saws has been read and understood in full DANGER Cuts from the...

Page 4: ...Saws Wall saw Components 1 Guide roller 10 Feed motor cable 2 Lock unit 11 Chassis 3 Water supply line 12 Carrying handle lock unit 4 Blade guard holder 13 Identification plate Blade drive motor 5 Gea...

Page 5: ...saw on the guide rail 1 2 If the grips fail to engage or the wall saw sits too loosely on the guide rail adjust the guide rollers Adjusting the guide rollers X X The guide rollers are set correctly wh...

Page 6: ...se original screws and bolts from TYROLIT Hydrostress AG DANGER Serious injury can be caused by sudden start up of the saw blade X X Switch off the control unit before working on the saw blade X X Iso...

Page 7: ...irection of rotation of the saw blade must match the direction of rotation of the machine Correct alignment Countersinking of the fastening holes against the blade cover For normal cuts with saw blade...

Page 8: ...7 For flush cuts X X Fastening the saw blade unit DANGER It can cause death or serious injury if the saw blade flies away X X Check whether the sleeve and central screw are countersunk X X Tighten the...

Page 9: ...juries can be caused if the saw blade drops down X X Lift out the saw blade unit to the top when removing it 1 2 Disassemble the saw blade unit in the reverse order to the assembly process Mounting th...

Page 10: ...IT Hydrostress AG Page 10 Wall saw WSE1217 Connecting the wall saw to the control unit 9 9 The control unit is isolated from the power supply 9 9 Connectors plugs are clean 9 9 Cables are undamaged X...

Page 11: ...ing A Wet cutting B Dry cutting Dry cutting For dry cutting the water is led away via a bypass When dry cutting continuous operation is not possible because otherwise the gearbox will overheat After u...

Page 12: ...d guide grooves X X X X X X Lubrication X X X Guide rollers X X Check the bearing clearance for wear X X X X X X Clean X X X X X X Replace X Swivel arm X X Check the saw blade uptake for wear X X X X...

Page 13: ...it X X Changing the gear oil The use of unsuitable oil can damage the wall saw X X Use only TYROLIT Hydrostress AG oil containers no 10981362 10 dl X X Replacing the guide rollers X X Defective guide...

Page 14: ...es with locking function Guide rollers Low wearing suitable for all VS and VAS rails Rail mounting Locking and safety function on carrying handle Main motor High frequency water cooled with quick rele...

Page 15: ...ke Parameter Value Gear reduction 1 256 Voltage 48 V Feed Toothed wheel on rail Feed motor swivel Electric feed motor with gears and brake Parameter Value Gear reduction 1 256 Voltage 48 V Swivel rang...

Page 16: ...m 900 mm 350 mm 1 000 mm 420 mm 1 200 mm 520 mm Lubricants fluids and sealants Lubricants fluids and sealants Parameter Value Gear oil swivel arm Kl ber GEM 4 150 N TYROLIT No 10981362 Lubricating gre...

Page 17: ...with the following direc tives and standards Directive applied 2006 42 EC from 17th May 2006 2004 108 EC from 17th December 2004 Applied standards EN 15027 A1 2009 EN 12100 2010 EN 60204 1 A1 2009 EN...

Page 18: ...TYROLIT Hydrostress AG Page 18 Wall saw WSE1217...

Reviews: