TYROLIT
Hydrostress AG
Page 16
Feed Unit SB-E
Starting the wire saw
9
The wire saw is firmly secured to the floor.
9
The protective devices are properly mounted.
9
The diamond wire is correctly installed.
9
The wire saw system and feed unit are correctly connected.
9
The wire saw system is connected to the mains power supply and the water supply.
9
The protective cap at the remote controller cable and connector is securely closed.
9
The EMERGENCY STOP on the remote controller is deactivated.
Starting the control unit
X
Move the operating elements listed below on the remote controller to their 0 position.
Feed potentiometer (6)
Start switch (5)
Feed joy stick (10)
Main motor On/Off (7)
X
Switch on the control unit WSE2226
using the main switch (11).
X
Switch on the radio remote controller using the start switch (5).
–
Warning lights (radio and battery) initially light up red
–
An audible signal sounds simultaneously
–
Indicators flash coloured
–
Second audible signal sounds
–
Indicators light up coloured
–
Warning light flashes green
X
Press the pulse switch (4) briefly on the radio remote controller to the ON position.
All indicator lights except the warning light and the group alarm on the radio remote
controller go off.
X
Press the reset button (12) on the control unit.
X
Briefly press the remote control pulse switch (4) in the ON-position.
The 'ready’ indicator light on the remote controller lights up green.
X
Open the water valve on the system supply line.
X
Press the Water On/Off switch (2) on the remote controller to I.
–
Water emerges at the cutting tool.
X
Press the main motor On/Off switch (7) on the remote controller to position I.
–
The electric motor starts when the main motor potentiometer is in the max. position.
X
The control unit WSE2226
has started up and is ready for operation.
4.2