background image

TYROLIT Hydrostress AG 

EC declaration of conformity 

 

Description 

Floor Saw 

Type designation 

FSG620



 

Year of construction 

2007 

Manufacturer 

TYROLIT Hydrostress AG 

 

We declare under our own liability that this product complies with the following directives and standards: 

 

Directive applied 

Machine Directive 

2006/42/EC 

Noise Emission 

2000/14/EC 

Electricity Directives 

93/68/EEC 

Electromagnetic Compatibility 

89/336/EEC 

2002/95/EC Restriction of the use of certain hazardous substances in 

electrical and electronic equipment 

2002/95/EC 

Waste Directive 

2002/96/EC 

Vibration Directive 

2002/44/EC 

 

 

Standards 

EN 12100-1  

 

Safety of machinery – Basic concepts, general design principles. 

EN 12100-2 

Safety of machinery - Basic concepts and general principles for design. 

EN ISO 14121 

Safety of machinery - Principles of risk assessment. 

EN 294 

Safety of machinery – Safety distances to prevent upper limbs reaching 

danger areas. 

IEC 60204-1 

Safety of machinery – Electrical equipment of machines, General 

Requirements. 

IEC 6100-6-3 

Electromagnetic Compatibility 

EN 13862 

Floor cutting-off machines. Safety. 

EN 349 

Safety of machinery – Safety distances to avoid crushing of body parts. 

EN 982 

Safety of machinery 

Safety requirements for safety systems and their components – 

hydraulics. 

EN ISO 3744 

Acoustics - Determination of sound power levels of noise sources using 

sound pressure 

 

Page 22 

Floor Saw FSG620



 

Summary of Contents for FSG620

Page 1: ...10987477 en 07 11 2008 Operating Instructions Floor Saw FSG620 Index 001...

Page 2: ...to honour our warranty obligations Any repair work must be carried out by trained personnel only Should you need more details concerning your TYROLIT Hydrostress unit in order to keep it in perfect co...

Page 3: ...er with the Safety Manual System Description for Floor Saws to form a complete set of documentation DANGER Failure to comply with the safety instructions in the Safety Manual System Description may re...

Page 4: ...rating console 2 Water tank 3 Name plate 4 Main motor 5 Cut guide 6 Shaft cover 7 Saw blade 8 Blade guard 9 Drive wheel 2 1 Saw blade drive Saw blade drive schematic 1 Blade drive shaft 2 Drive belt 3...

Page 5: ...ft drive Lift drive schematic 1 Movable spindle 2 3 Travel drive Travel drive schematic 1 Drive shaft main motor 2 Hydrostat drive belt 3 Hydrostatic motors 4 Drive chain 5 Wheel drive shaft 6 Drive w...

Page 6: ...ls and load suspension devices with sufficient load bearing capacity must be used Floor saws must only be hitched by the hitching points provided Appoint an expert marshaller When transporting by cran...

Page 7: ...TYROLIT Hydrostress AG 4 Initial start up 4 1 Fitting battery Fit battery for type see Technical Data Floor Saw FSG620 Page 7...

Page 8: ...TYROLIT Hydrostress AG 5 Assembly Set up 5 1 Mounting grip 5 2 Mounting saw blade 1 Apply footbrake Page 8 Floor Saw FSG620...

Page 9: ...ated with a blade guard When assembling the saw blade on the right hand side use the anchoring screw with the left hand thread When assembling the saw blade on the left hand side use the anchoring scr...

Page 10: ...stress AG 4 C To prevent the saw blade rotating while being tightened carefully place the saw blade on the floor 5 3 Mounting saw blade on the other side 5 3 1 Disassemble the blade guard Page 10 Floo...

Page 11: ...side Assembly of the blade guard and the shaft cover is performed in the opposite order to disassembly 5 4 Connecting water line The water tank should also always be full when an external water suppl...

Page 12: ...wer hand wheel 2 Choke 3 Ignition key 4 Feed adjuster forward backward travel 5 Speed governor 6 EMERGENCY STOP switch 7 Foot brake 8 Battery main switch 9 Feed gears coupling lever 10 Operating hours...

Page 13: ...the tank display 1 and top up with ROZ 95 petrol as necessary 6 4 Positioning the floor saw 1 Release footbrake 2 Slide floor saw into the working position 3 Fit the cutting guides to the floor saw 6...

Page 14: ...n Coupling lever in uncoupled position 9 Coupling lever 5 is in the uncoupled position 9 EMERGENCY STOP switch 3 has been released 1 Pull out choke 1 according to temperature 2 Start motor with igniti...

Page 15: ...drostress AG 6 7 Lowering raising saw blade Symbol Significance Raising lowering saw blade 1 Lower joint cutter with the hand wheel 1 to the desired cutting depth 2 Engage locking pin 2 Floor Saw FSG6...

Page 16: ...led position Feed adjuster in the forwards direction of travel Feed adjuster in the backwards direction of travel 9 Feed adjuster 1 is in the neutral position 9 Footbrake 2 is released 1 Place couplin...

Page 17: ...Annually or every 100 operating hours Arrange a major service by TYROLIT Hydrostress AG or an authorised representative According to the information from the motor manufacturer Carry out all necessary...

Page 18: ...TYROLIT Hydrostress AG 7 2 Tensioning chain on travel drive Tensioning chain 1 Chain Page 18 Floor Saw FSG620...

Page 19: ...though the motor is running Pulling pin on the anchoring flange has sheared off Mount new anchoring flange Operation of the control rods impaired Check control rods and repair as necessary Defective...

Page 20: ...9 2 Motor Parameter Value Type Honda Power 20 PS Rated speed According to operating instructions from motor manufacturer Oil content According to operating instructions from motor manufacturer Tank co...

Page 21: ...wing condition Travel drive is switched off and the saw blade is not engaged The measurement is performed with the motor under full load with the saw blade dia 600 mm Higher noise levels may be genera...

Page 22: ...EC Standards EN 12100 1 Safety of machinery Basic concepts general design principles EN 12100 2 Safety of machinery Basic concepts and general principles for design EN ISO 14121 Safety of machinery Pr...