Malfunctions
Malfunction Possible
cause
Solution
Floor saw does not operate
EMERGENCY STOP
switch has been pressed.
►
Release
EMERGENCY STOP
switch.
Saw blade jammed
Saw blade is jammed in the cutting material
►
Reverse the floor saw.
►
If necessary release the saw blade by
rocking.
►
If necessary stop the motor, disassemble
the saw blade and release this
individually from the cutting material.
Belt tension too slack
►
Tension or replace belt.
Saw blade does not rotate even
though the motor is running
Pulling pin on the anchoring flange has
sheared off
►
Mount new anchoring flange.
Operation of the control rods impaired
►
Check control rods and repair as
necessary.
Defective hydrostat
►
Check hydrostat and if necessary have
this repaired by a TYROLIT Hydrostress
engineer.
Defective chain
►
Have the chain replaced by a TYROLIT
Hydrostress engineer.
Feed not working
Main motor belt slipping
►
Check belt for wear and if necessary
have this replaced by a TYROLIT
Hydrostress engineer.
►
Increase belt tension as necessary.
Wrong fuel
►
Switch off motor immediately and
change fuel.
Motor running off centre
Diesel filter blocked
►
Have diesel filter changed.
Defective contacts on the connection
between battery and generator
►
Check contacts and re-establish these as
necessary.
Battery display lights
Inadequate battery charging
►
Charge or change battery.
Oil temperature too high
►
Allow floor saw to run under no load
until temperature display goes off.
Oil temperature display lights
Too little oil
►
Top up oil.
Oil pressure display lights
Defective oil pump
►
Have oil pump changed.
Floor Saw FSD930
Page 21