oPerAtion
19
Extension cables
INFORMATION
•
Only use approved and appropriately marked extension cables outdoors.
•
Avoid the use of extension cables with multiple sockets and the simultaneous operation
of several devices.
Only use extension cables that are approved for the field of application and with an
adequate cable cross-section.
INFORMATION
Recommended minimum cross-sections and max. cable lengths
Conductor cross-section mm²
1.5
2.5
4.0
6.0
220 V - 240 V
30 m
50 m
80 m
120 m
Extraction
Connect the dust extractor to the grinding machine. You can find information on
connections in the documentation of the different TYROLIT dust extractor models.
DANGER
Released dust particles can damage your health.
▶
Always use a dust extractor during work.
Extraction