background image

TYROLIT

 

Hydrostress AG

Page 14

Wall saw DZ-S2

Lubricants, fluids and sealants

Lubricants, fluids and sealants

Parameter

Value

Lubricating grease (lock unit)

Penetration

265 to 295

NLGI

2

Connectable drive units

The wall saw must only be operated with the coordinated drive units from TYROLIT Hydrostress.

Drive unit power requirements:

Parameter

Value

Minimum output:

12 kW (max. operating pressure 260 bar)

Maximum performance

20 kW (max. operating pressure 260 bar)

Water connection

Parameter

Value

Pressure

2 to 6 bar

Quantity

At least 6 l/min

Max. temperature

25 °C

5.8

5.9

Summary of Contents for DZ-S2

Page 1: ...Operating Instructions Wall saw DZ S2 Index 001 10987273 EN 25 07 2007...

Page 2: ...genuine TYROLIT Hy drostress replacement parts can guarantee quality and interchangeability We are unable to ful fil our warranty obligations if maintenance work is neglected or carried out unprofessi...

Page 3: ...n the Safety Manual System Manual may re sult in serious injury or even death Please ensure that the Safety Manual System Description for Wall Saws has been read and understood in full DANGER Cuts fro...

Page 4: ...saw Components 1 Feed motor swivel 6 Blade drive motor 2 Blade guard holder 7 Saw blade holder 3 Water connection 8 Name plate 4 Feed motor travel 9 Chassis 5 Lock unit 10 Belt swivel arm 2 10 9 8 Ty...

Page 5: ...TYROLIT Hydrostress AG Page Wall saw DZ S2 Assembly disassembly Place the wall saw on the guide rail 1 2 3 3 1...

Page 6: ...age Wall saw DZ S2 Adjustment of the closure A Rotate as far as the stop B Rotate back two notch positions Release the closure Perform the remaining assembly steps in reverse order 1 2 click click A B...

Page 7: ...s AG DANGER Serious injury can be caused by sudden start up of the saw blade Switch off the drive unit before working on the saw blade Depressurize the hoses Fixing saw blade in position The direction...

Page 8: ...TYROLIT Hydrostress AG Page Wall saw DZ S2 For flush cuts Mount the blade guard Mount the blade guard according to the instruction leaflet C D6x A B6x C D6x A B6x 3 6...

Page 9: ...TYROLIT Hydrostress AG Page Wall saw DZ S2 Connecting the wall saw to the drive unit The drive unit is isolated from the power supply Couplings are clean Hoses are undamaged 3 7...

Page 10: ...the rail or the chassis touches the rail X Y guides Apply 2 3 applications of grease to the lubricating nipples X Couplings Check for leak tightness and damage and replace as required X Swivel arm Cle...

Page 11: ...on 1 2 Lock unit Low wearing suitable for all VS and VAS rails Rail mounting Locking and securing function at the prism guide Blade drive motor Secured by means of quick release device hydraulic motor...

Page 12: ...Size 2 Absorption volume 12 to 30 cm3 Transmission ratio 1 2 Operating pressure max 260 bar Type External geared motor Rotational speeds hydraulic motors for wall saws cm3 12 cm3 16 cm3 18 cm3 22 cm3...

Page 13: ...ing pressure max 120 bar Output torque 50 Nm Swivel range swivel arm 360 Feed force 3 000 N Saw blades Saw blades Parameter Value Saw blade max 1 200 mm Fully detachable saw blade 900 mm Blade holder...

Page 14: ...2 Connectable drive units The wall saw must only be operated with the coordinated drive units from TYROLIT Hydrostress Drive unit power requirements Parameter Value Minimum output 12 kW max operating...

Page 15: ...ives and standards Directive applied Machinery Directives 2006 42 EC Standards applied EN 12100 1 EN 12100 2 Safety of machines Basic concepts general design principles EN 294 Safety of machinery Safe...

Page 16: ......

Reviews: