background image

7

BATTERY STATUS

The LED Battery Indicator provides the current state of charge on the internal battery. It is the 

user’s responsibility to periodically monitor the battery’s status and recharge every 3 months in 

addition to recharging after each use. 

1.  Disconnect any input or output power cords and turn off all switches. 
2.  Press and hold the Battery Status button.
3.  Observe the LED indicator to determine battery status. 

• Red: Battery is discharged. Charge immediately.

• Green 1: Battery voltage is capable to be used.

.

CHARGING THE BATTERY JUMPER

ELECTRICAL SHOCK! Exposure to water may cause electrical shock� Exposure to 

water and excessive moisture will also damage the unit and void the warranty�

Charge your Battery Jumper in an upright position for a full 20 hours before initial use�

 

Continue to maintain the life of your Battery Jumper (as with all lead-acid batteries) by fully 

recharging the unit every 3 months even if the Battery Jumper has not been used. 

AC Charging

Only use the AC charging adapter supplied with this unit� 

Make sure the supplied AC/DC 

charging adapter is to be powered by the correct voltage (110V AC or 220V AC depending on 

your country/region).  

1.  Make sure all Battery Jumper switches are off.
2.  Open the dust cover on the Charging Jack.
3.  Plug the DC end of the AC/DC charging adapter into the Battery Jumper ’s charging jack.
4.  Connect the AC end of the AC/DC charging adapter to the wall outlet.
5.  The Battery/Charging Indicator will light up red/yellow/green 1/green 2 gradually during the charging 

process.   The Battery Jumper

 

can be charged continuously via AC adapter without 

damaging the internal battery.

6.  When charging is complete, the Charging Indicator will turn green. Disconnect the adapter 

from the AC outlet first, then from the charging jack.

7.  Replace the dust cover on the Charging Jack.

8.  Press the Battery Status Button and observe the Battery Status/Charging Indicator for the 

state of charge on the unit’s internal battery. The Battery Status/Charging Indicator should 

be lit green if charge is complete.

DC Charging in Your Vehicle or Boat

Only use the DC charging adapter supplied with this unit� 

Your vehicle 

engine must be running 

while charging the Battery Jumper. 

Do NOT exceed 12 hours

 of continuous charging time.

1.  Make sure all Battery Jumper switches are off.

• Yellow: Battery voltage is low,need to be charged.

• Green 2: Battery is fully charged

.

Summary of Contents for HH399

Page 1: ...r Item No HH399 User s Manual CHARGE UNIT FOR 20 HOURS BEFORE FIRST USE We are constantly improving our products so specifications are subject to change without notice Visit our website for the latest...

Page 2: ...cations 7 Front View 8 Rear View 9 Battery Status 10 Charging the Battery Jumper 10 AC Charging 10 DC Charging in Your Vehicle or Boat 10 Jump Starter 11 Warnings 11 Procedure 11 Air Compressor 12 Pro...

Page 3: ...heir safety For proper and safe operation of any accessory outlet do not place anything in it except the plug of the accessory to be used Use only the chargers cables and clamps provided Unauthorized...

Page 4: ...power port for charging mobile devices Bright long lasting LED worklight AC DC recharging adapter DC recharging cable fused included SPECIFICATIONS Battery AGM Sealed lead acid 12V 8Ah Peak Amps 450A...

Page 5: ...5 FRONT VIEW 1 Worklight Switch 2 Pressure guage 3 LED worklight 4 USB Power port 5 compressor Switch 6 Air hose compartment 7 Jumper Cable 8 Air hose 1 2 3 4 4 5 6 7 8 9 9 Battery status indicators...

Page 6: ...User s Manual Read before using this equipment 6 REAR VIEW 1 Battery status button 2 12V DC socket 3 Charging jack 1 2 3...

Page 7: ...y the correct voltage 110V AC or 220V AC depending on your country region 1 Make sure all Battery Jumper switches are off 2 Open the dust cover on the Charging Jack 3 Plug the DC end of the AC DC char...

Page 8: ...le jump starting Jump start a vehicle or boat in a well ventilated area Do not attempt to jump start a frozen battery This product is not intended for use in the rain or temperatures above 130 F Do no...

Page 9: ...le component or body part DO NOT clamp directly to positive battery terminal or a moving part 7 Inside the vehicle turn on the ignition switch and attempt to start the engine 8 Crank a maximum of 3 se...

Page 10: ...or the pressure gauge while inflating the tire 9 When recommended tire pressure has been reached turn off the air compressor 10 Disconnect the hose and replace valve cap 11 Return the hose back to its...

Page 11: ...on the Battery Jumper 2 Press the battery status button USB power port will be working 3 When charge is complete disconnect the USB cable from the WORKLIGHT You may operate the worklight and DC socket...

Page 12: ...des and disclaims any and all other warranties expressed or implied or statutory merchantability or fitness for a particular purpose This limited warranty is void if the product is misused subjected t...