Tynetec ZXT485 Manual Download Page 2

Doc

 

No.

 

FM0706

 

issue

 

D

 

Page

 

2

 

INITIAL

 

SET

UP

 

 

From

 

new

 

you

 

will

 

need

 

to

 

open

  

the

 

battery

 

compartment

 

and

  

remove

 

the

 

battery

 

isolation

 

strip.

 

 

The

 

display

 

will

 

show

 

BOOT

  

followed

 

by

 

the

 

software

 

version

  

e.g.

 

SW

007

 

then

 

the

 

battery

 

charge

 

level

 

B

 

100%”

 

(full

 

charge).

 

When

 

the

 

display

 

shows

 

CLOCK

 

and

 

flashes

 

00:00

 

the

 

unit

 

is

 

ready

 

to

 

program.

  

 

There

 

are

 

2

 

programming

 

menus;

 

Menu

 

A

 

contains

 

the

 

basic

 

settings

 

and

 

Menu

 

B

 

contains

 

more

 

advanced

 

functions.

 

See

 

below;

 

 

MENU

 

A

 

SETTINGS

 

 

Press

 

button

 

1

 

to

 

cycle

 

through

 

the

 

following

 

functions;

 

CLOCK

 

 

DATE

 

 

DOSES

 

 

ALARMS

 

 

Press

 

and

 

hold

 

button

 

1

 

for

 

3

 

seconds

 

to

 

exit

 

the

 

menu

 

and

 

revert

 

to

 

normal

 

operation.

  

 

Setting

 

the

 

Clock

 

Press

 

button

 

1

 

once

 

and

 

CLOCK

 

is

 

displayed.

 

Press

 

button

 

2/3

 

to

 

set

 

the

 

time

 

(00:00

 

to

 

23:59)

  

Note:

 

press

 

and

 

hold

 

for

 

fast

 

forward/reverse

 

Press

 

button

 

1

 

to

 

end

 

and

 

DATE

 

will

 

be

 

displayed.

 

 

Setting

 

the

 

Date

   

The

 

DATE

 

display

 

will

 

change

 

to

 

YY

 

after

 

a

 

few

 

seconds.

 

Press

 

button

 

2/3

 

to

 

set

 

the

 

YEAR

 

(00

 

to

 

99)

 

Press

 

button

 

1

 

and

 

MM

 

will

 

be

 

displayed

 

Press

 

button

 

2/3

 

to

 

set

 

the

 

MONTH

 

(01

 

to

 

12)

 

Press

 

button

 

1

 

and

 

DD

 

will

 

be

 

displayed

 

Press

 

button

 

2/3

 

to

 

set

 

the

 

DATE

 

(01

 

to

 

31)

 

Press

 

button

 

1

 

to

 

end

 

and

 

DOSES

 

will

 

be

 

displayed.

 

 

Setting

 

the

 

Number

 

of

 

Doses

 

per

 

Day

 

The

 

DOSES

 

display

 

will

 

change

 

to

 

display

 

the

 

number

 

of

 

doses

 

per

 

day

 

after

 

a

 

few

 

seconds.

 

Press

 

button

 

2/3

 

to

 

set

 

the

 

doses

 

per

 

day

 

(00

 

to

 

24)

 

Press

 

button

 

1

 

to

 

end

 

and

 

ALARMS

 

will

 

be

 

displayed.

  

 

Setting

 

the

 

Alarm

 

Times

 

for

 

each

 

Dose

 

The

 

ALARMS

 

display

 

will

 

change

 

to

 

display

 

the

 

time

 

for

 

the

 

first

 

dose

 

after

 

a

 

few

 

seconds.

 

Press

 

button

 

2/3

 

to

 

set

 

the

 

alarm

 

time

 

for

 

the

 

first

 

dose

 

Press

 

button

 

1

 

to

 

end

 

then

 

set

 

alarm

 

time

 

2

 

Repeat

 

for

 

each

 

alarm

 

time,

 

the

 

number

 

of

 

alarm

 

times

 

is

 

determined

 

by

 

the

 

“number

 

of

 

doses

 

per

 

day”

 

set

 

above.

 

 

MENU

 

B

 

SETTINGS

 

 

Press

 

and

 

hold

 

button

 

3

 

until

 

BEFORE

 

is

 

displayed

 

then

 

press

 

button

 

1

 

to

 

cycle

 

through;

 

AFTER

 

SOUND

 

LIGHT

 

FILLED

 

BATT

 

SECURE

 

HOURS

 

 

DLS

 

START

 

STOP

 

RECORD

 

Press

 

and

 

hold

 

button

 

1

 

for

 

3

 

seconds

 

to

 

exit

 

the

 

menu

 

and

 

revert

 

to

 

normal

 

operation.

 

 

Setting

 

the

 

Before

 

Time

 

The

 

BEFORE

 

time

 

allows

 

medication

 

to

 

be

 

taken

 

up

 

to

 

5

 

hours

 

earlier

 

than

 

the

 

next

 

alarm

 

time.

 

Press

 

and

 

hold

 

button

 

3

 

until

 

BEFORE

 

is

 

displayed

 

Press

 

button

 

2/3

 

to

 

set

 

the

 

before

 

time

 

(00:00

 

=

 

not

 

required,

 

to

 

05:00

 

max)

  

Press

 

button

 

1

 

to

 

end

 

and

 

AFTER

 

will

 

be

 

displayed

 

If

 

this

 

option

 

is

 

set

 

the

 

user

 

may

 

access

 

their

 

medication

 

in

 

advance

 

by

 

turning

 

the

 

pill

 

dispenser

 

upside

 

down

 

then

 

back

 

upright

 

again

 

twice

 

in

 

succession,

 

the

 

tray

 

will

 

rotate

 

one

 

step

 

and

 

the

 

next

 

dose

 

will

 

become

 

available.

 

 

Setting

 

the

 

After

 

Time

 

The

 

AFTER

 

time

 

sets

 

how

 

long

 

the

 

alarm

 

sounds

 

and

 

the

 

pill

 

shutter

 

remains

 

unlocked

 

after

 

the

 

medication

 

is

 

due.

 

After

 

AFTER

 

is

 

displayed;

  

Press

 

button

 

2/3

 

to

 

set

 

the

 

after

 

time

 

(00:05

 

to

 

05:00)

  

Press

 

button

 

1

 

to

 

end

 

and

 

SOUND

 

will

 

be

 

displayed.

  

If

 

half

 

the

 

AFTER

 

time

 

expires

 

an

 

alarm

 

call

 

will

 

be

 

transmitted.

 

If

 

the

 

full

 

AFTER

 

time

 

expires

 

another

 

alarm

 

call

 

will

 

be

 

transmitted

 

and

 

the

 

pill

 

shutter

 

will

 

lock

 

shut.

  

 

Setting

 

the

 

Alarm

 

Sound

 

The

 

alarm

 

SOUND

 

will

 

play

 

to

 

alert

 

the

 

user

 

when

 

it

 

is

 

time

 

to

 

take

 

their

 

medication.

 

It

 

will

 

sound

 

every

 

5

 

seconds

 

for

 

the

 

first

 

minute,

 

then

 

every

 

8

 

seconds

 

up

 

to

 

1

 

hour

 

then

 

once

 

a

 

minute

 

until

 

the

 

medication

 

is

 

dispensed

 

or

 

the

 

AFTER

 

time

 

is

 

reached,

 

maximum

 

5

 

hours.

 

After

 

SOUND

 

is

 

displayed;

 

Press

 

buttons

 

2/3

 

to

 

select

 

the

 

preferred

 

sound

 

(01

 

to

 

04)

 

Select

 

00

 

for

 

no

 

sound

 

Press

 

button

 

1

 

to

 

end

 

and

 

LIGHT

 

will

 

be

 

displayed.

 

 

Setting

 

the

 

Light

 

On/Off

 

The

 

LIGHT

 

will

 

flash

 

to

 

alert

 

the

 

user

 

when

 

it

 

is

 

time

 

to

 

take

 

their

 

medication.

 

It

 

will

 

flash

 

every

 

5

 

seconds

 

for

 

the

 

first

 

minute,

 

then

 

every

 

8

 

seconds

 

up

 

to

 

1

 

hour

 

then

 

once

 

every

 

16

 

seconds

 

until

 

the

 

medication

 

is

 

dispensed

 

or

 

the

 

AFTER

 

time

 

is

 

reached,

 

maximum

 

5

 

hours.

  

After

 

LIGHT

 

is

 

displayed;

 

Press

 

button

 

2

 

for

 

no

 

light

 

(display

 

shows

 

OFF)

 

Press

 

button

 

3

 

for

 

light

 

(display

 

shows

 

ON)

  

Press

 

button

 

1

 

to

 

end

 

and

 

FILLED

 

will

 

be

 

displayed.

 

 

Setting

 

the

 

Filled

 

Quantity

  

This

 

is

 

the

 

number

 

of

 

doses

 

placed

 

in

 

the

 

medication

 

tray

 

when

 

filled

 

and

 

allows

 

the

 

DOSES

 

LEFT

 

display

 

to

 

be

 

shown.

  

After

 

FILLED

 

is

 

displayed;

 

Press

 

button

 

2/3

 

to

 

set

 

the

 

FILLED

 

quantity

 

(00

 

to

 

28)

 

Press

 

button

 

1

 

to

 

end

 

and

 

BATT

 

will

 

be

 

displayed.

 

 

Setting

 

the

 

Battery

 

Type

 

It

 

is

 

possible

 

to

 

use

 

4

 

x

 

AA

 

size

 

alkaline

 

or

 

4

 

x

 

AA

 

size

 

rechargeable

 

batteries

 

in

 

the

 

‘Advance’

 

Pill

 

Dispenser.

 

After

 

BATT

 

is

 

displayed;

 

Press

 

button

 

2

 

to

 

select

 

alkaline

 

(

ALC

)

  

Press

 

button

 

3

 

to

 

select

 

rechargeable

 

(

NIMH

)

  

Press

 

button

 

1

 

to

 

end

 

and

 

SECURE

 

will

 

be

 

displayed.

 

 

Setting

 

the

 

Secure

 

Mode

 

With

 

SECURE

 

mode

 

ON

 

the

 

pill

 

shutter

 

will

 

be

 

locked

 

except

 

at

 

alarm

 

time

 

and

 

for

 

the

 

subsequent

 

after

 

time.

 

With

 

SECURE

 

mode

 

OFF

 

the

 

shutter

 

does

 

not

 

lock.

  

After

 

SECURE

 

is

 

displayed;

 

Press

 

button

 

2

 

to

 

select

 

secure

 

mode

 

ON

  

Press

 

button

 

3

 

to

 

select

 

secure

 

mode

 

OFF

  

Press

 

button

 

1

 

to

 

end

 

and

 

HOURS

 

will

 

be

 

displayed.

 

 

Setting

 

the

 

Hours

 

Mode

 

The

 

clock

 

can

 

be

 

set

 

to

 

display

 

the

 

time

 

in

 

12

 

hour

 

AM/PM

 

mode

 

or

 

24

 

hour

 

mode.

 

After

 

HOURS

 

is

 

displayed;

 

Press

 

button

 

2

 

to

 

select

 

12

 

hour

 

clock

 

(AM/PM)

  

Press

 

button

 

3

 

to

 

select

 

24

 

hour

 

clock

  

Press

 

button

 

1

 

to

 

end

 

and

 

DLS

 

will

 

be

 

displayed.

 

 

Setting

 

the

 

Daylight

 

Saving

 

Mode

 

To

 

clock

 

can

 

be

 

set

 

to

 

automatically

 

adjust

 

+/

‐ 

1

 

hour

 

every

 

March/October

 

for

 

GMT/BST.

 

After

 

DLS

 

is

 

displayed;

 

Press

 

button

 

2/3

 

to

 

select

 

OFF/EU/US

 

Set

 

EU

 

for

 

Europe,

 

US

 

for

 

America

 

or

 

OFF

 

to

 

disable.

  

Press

 

button

 

1

 

to

 

end

 

and

 

START

 

will

 

be

 

displayed.

 

 

Summary of Contents for ZXT485

Page 1: ...s ready and pills taken times are also transmitted and logged in the Reach Plus or Advent xt This data can be analysed using Tynetec s iCare software Note Advent xt requires additional hardware Loadin...

Page 2: ...sets how long the alarm sounds and the pill shutter remains unlocked after the medication is due After AFTER is displayed Press button 2 3 to set the after time 00 05 to 05 00 Press button 1 to end an...

Page 3: ...rd to demonstrate dispensing the medication The display will show CLOSE and the tray will turn to the locked position Press button 3 to repeat or press and hold button 1 for a few seconds to end This...

Page 4: ...he 8 digit pill dispenser ID to be deleted after the Beep press to exit Press the key to exit Program Mode the unit will sound a Double Beep and the front light will return to STEADY GREEN The 8 digit...

Page 5: ...dispenser to be deleted Wait for the Pendant Disabled Enter Flat prompt Press the key and wait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators ma...

Page 6: ...R key Refer to the Altec Response installation guide Doc No FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Open the lid press and hold all 3...

Page 7: ...penser from a Touchsafe Pro Nursecall system Select the pill dispenser ID to be deleted from the Delete Telecare Device pull down list box prefixed with a T31 Details of the pill dispenser selected wi...

Reviews: