Tynetec ZXT422 Manual Download Page 2

Doc

 

No.

 

FM0456

 

issue

 

F

  

Page

 

2

  

Activating

 

&

 

Deactivating

 

the

 

CO

 

Detector

 

 

Remove

 

the

 

top

 

cover

 

and

 

withdraw

 

the

 

red

 

PULL

 

tab

 

to

 

connect

 

the

 

batteries

 

and

 

activate

 

the

 

detector.

  

The

 

GREEN

,

 

RED

 

and

 

YELLOW

 

lights

 

will

 

flash

 

in

 

sequence.

 

The

 

GREEN

 

light

 

will

 

blink

 

every

 

45

 

seconds

 

when

 

activated.

 

 

The

 

CO

 

detector

 

cannot

 

be

 

turned

 

off.

 

When

 

unit

 

is

 

approaching

 

its

 

end

 

of

 

life

 

it

 

will

 

emit

 

a

 

beep

 

and

 

flash

 

the

 

GREEN

 

light

 

simultaneously

 

every

 

45

 

seconds.

 

Remove

 

the

 

top

 

cover

 

and

 

cut

 

the

 

BLACK

 

WIRE

 

to

 

deactivate

 

(see

 

drawing

 

above).

 

 

Testing

 

the

 

CO

 

Detector

 

 

Press

 

and

 

hold

 

the

 

TEST

 

&

 

HUSH

 

button

 

for

 

at

 

least

 

5

 

seconds,

  

the

 

GREEN

 

light

 

will

 

flash

 

and

 

the

 

horn

 

will

 

sound.

  

 

The

 

TEST

 

&

 

HUSH

 

button

 

must

 

be

 

pressed

 

when

 

registering

 

the

 

CO

 

detector

  

onto

 

the

 

warden

 

call

 

system,

 

at

home

 

alarm

 

or

 

Nursecall

 

system.

 

 

 

 

  

 

See

 

the

 

following

 

pages

 

for

 

how

 

to

 

put

 

each

 

of

 

these

 

products

 

into

 

registration

 

mode.

  

 

    

The

 

range

 

of

 

all

 

radio

 

devices

 

can

 

be

 

affected

 

by

 

the

 

working

 

environment.

 

    

Always

 

take

 

care

 

during

 

installation

 

and

 

perform

 

several

 

test

 

calls.

 

 

Mask

 

Time

 

&

 

Battery

 

Test

 

 

CO

 

detectors

 

include

 

a

 

15

 

minute

 

mask

 

time

 

to

 

prevent

 

alarm

 

calls

 

re

reporting

  

and

 

an

 

Engineers

 

mask

 

reset/battery

 

test

 

function.

  

 

When

 

the

 

detector

 

is

 

activated

 

the

 

alarm

 

call

 

will

 

be

 

transmitted

 

once,

 

no

 

further

  

transmissions

 

will

 

occur

 

for

 

15

 

minutes

 

giving

 

time

 

for

 

the

 

cause

 

of

 

the

 

alarm

 

to

 

clear.

 

 

Engineers

 

mask

 

reset

 

function;

 

open

 

the

 

cover,

 

press

 

and

 

hold

 

BUTTON

 

1

 

on

 

the

 

transmitter

  

for

 

2

 

seconds

 

until

 

the

 

red

 

light

 

flashes

 

once.

 

After

 

a

 

short

 

delay

 

the

 

red

 

light

 

will

 

flash

 

once

 

more

  

to

 

indicate

 

the

 

mask

 

time

 

is

 

reset

 

and

 

the

 

battery

 

power

 

is

 

OK.

 

If

 

the

 

red

 

light

 

flashes

 

several

 

times

 

the

 

battery

 

power

 

is

 

low.

 

 

 

In

 

Case

 

of

 

Carbon

 

Monoxide

 

Alarm

 

 

If

 

a

 

potentially

 

dangerous

 

level

 

of

 

carbon

 

monoxide

 

is

 

detected

 

the

 

RED

 

light

 

will

 

flash

 

and

 

the

 

audible

 

alarm

 

will

 

sound.

 

 

Open

 

windows

 

and

 

doors

 

to

 

ventilate

 

the

 

area

 

Press

 

the

 

TEST

 

&

 

HUSH

 

button

 

to

 

silence

 

the

 

alarm

 

for

 

4

 

minutes

 

If

 

the

 

alarm

 

does

 

not

 

silence

 

the

 

level

 

of

 

CO

 

is

 

dangerously

 

high

 

(300ppm)

 

 

If

 

the

 

alarm

 

does

 

not

 

re

sound

 

after

 

4

 

minutes

 

it

 

is

 

safe

 

for

 

a

 

qualified

 

person

 

to

 

find

 

the

 

cause

 

of

 

the

 

alarm.

  

If

 

the

 

alarm

 

continues

 

turn

 

the

 

appliance

 

off

 

and

 

do

 

not

 

use

 

until

 

it

 

has

 

been

 

checked

 

by

 

a

 

qualified

 

person.

 

Get

 

medical

 

help

 

for

 

anyone

 

suffering

 

headaches

 

or

 

nausea,

 

advise

 

that

 

carbon

 

monoxide

 

poisoning

 

is

 

suspected.

 

 

Alarm

 

Memory

 

 

If

 

the

 

RED

 

light

 

flashes

 

2

 

times

 

every

 

40

 

seconds

 

a

 

50ppm

 

level

 

of

 

CO

 

has

 

been

 

detected

 

for

 

at

 

least

 

90

 

minutes.

 

If

 

the

 

RED

 

light

 

flashes

 

4

 

times

 

every

 

40

 

seconds

 

a

 

100ppm

 

level

 

of

 

CO

 

has

 

been

 

detected

 

for

 

at

 

least

 

40

 

minutes.

 

If

 

the

 

RED

 

light

 

flashes

 

8

 

times

 

every

 

40

 

seconds

 

a

 

300ppm

 

level

 

of

 

CO

 

has

 

been

 

detected

 

for

 

at

 

least

 

3

 

minutes.

 

Press

 

and

 

hold

 

the

 

TEST

 

&

 

HUSH

 

button

 

for

 

20

 

seconds

 

to

 

clear

 

the

 

memory.

 

Get

 

all

 

appliances

 

checked

 

by

 

a

 

qualified

 

person.

 

 

In

 

Case

 

of

 

Fault

 

 

If

 

the

 

unit

 

beeps

 

and

 

the

 

YELLOW

 

light

 

blinks

 

simultaneously

 

every

 

45

 

seconds

 

there

 

is

 

a

 

fault

 

with

 

the

 

sensor.

  

The

 

unit

 

is

 

probably

 

defective

 

and

 

must

 

be

 

replaced.

  

 

False

 

Alarms

 

 

It

 

is

 

possible

 

tobacco

 

smoke,

 

household

 

cleaning

 

agents,

 

paint,

  

air

 

fresheners,

 

insect

 

sprays,

 

bleaches,

 

hair

 

sprays,

 

polishes

  

or

 

other

 

aerosols

 

can

 

cause

 

false

 

alarms.

 

 

Cleaning

 

&

 

Decorating

 

 

It

 

is

 

recommended

 

to

 

clean

 

the

 

detector

 

periodically

 

using

 

the

 

nozzle

 

attachment

 

on

 

a

 

vacuum

 

cleaner

 

to

  

remove

 

dust,

 

insects

 

and

 

cobwebs

 

from

 

the

 

cover

 

slots.

 

The

 

detector

 

can

 

be

 

wiped

 

clean

 

with

 

a

 

damp

 

cloth,

 

never

 

use

 

detergents

 

or

 

polish

 

etc.

 

Avoid

 

spraying

 

any

 

aerosols

 

near

 

the

 

detector.

 

Never

 

paint

 

the

 

CO

 

detector

 

itself.

 

When

 

decorating

 

cover

 

the

 

CO

 

detector

 

with

 

a

 

plastic

 

bag

 

to

 

avoid

 

contamination

 

from

 

water

 

or

 

dust.

 

 

Battery

 

Life

 

 

The

 

transmitter

 

battery

 

is

 

checked

 

once

 

a

 

day,

 

if

 

the

 

voltage

 

falls

 

and

 

stays

 

below

 

a

 

preset

 

level

 

for

 

7

 

consecutive

 

days

 

a

 

low

 

battery

 

alert

 

is

 

automatically

 

transmitted.

 

Once

 

a

 

low

 

battery

 

call

 

is

 

received

 

the

 

CO

 

detector

 

should

 

be

 

replaced

 

within

 

7

 

days.

  

Detailed

 

information

 

on

 

battery

 

management

 

for

 

all

 

Tynetec/Aidcall

 

products

 

is

 

available

 ‐ 

request

 

Doc

 

No.

 

FM0630.

  

 

 

 

TEST

 

&

 

HUSH

 

BUTTON

 

PRESS

 

AND

 

HOLD

 

BUTTON

 

1

 

TO

 

RESET

 

THE

 

MASK

 

TIME

 

THE

 

RED

 

LIGHT

  

WILL

 

FLASH

 