Doc No. FM0626 issue C Page 5
Registering a Property Exit Sensor onto an
Altec Response
local carer alarm unit
1.
Put the Altec Response unit into radio device learn mode…
2. Activate the property exit sensor
…
3.
Exit the Altec Response radio device learn mode…
4.
Turn the rotary switch to the “0” position, o
pen and close the front door, do not trigger the PIR and check a
“
door exit
” alarm is
displayed on the Altec Response unit. Open the front door, leave it open then trigger the PIR and check a “
door open
” alarm is
displayed on the Altec Response unit.
Remember to reset the rotary switch after testing.
Deleting a Property Exit Sensor from an
Altec Response
local carer alarm unit
Press
ENTER
to activate the wake-up display then
ENTER
again to display the main menu
Press
ENTER
to select
Radio Devices
Press the
key
to select
Delete Device
then press
ENTER
The display
will prompt you to “
Trigger the Sensor
”
With the door closed, swipe the PIR to be deleted - the display will show the device type and its 8 digit ID
If this is the device you activated press the
key to select
Delete
then press
ENTER
With the door closed, swipe the PIR again, the display will show the device type and its 8 digit ID
If this is the device you activated press the
key to select
Delete
then press
ENTER
Note: if the ID is NOT the device you activated press the
ENTER
key to select
Reject
then try again
To exit the mode select
Exit
then press the
ENTER
key.
Refer to the Altec Response installation guide (Doc No. FM0548) provided with the portable alarm unit for
more information on programming and testing radio devices.
Tynetec and Aidcall operate a policy of continuous improvement and reserve the right to change product specifications without notice.
If any variation to the details contained in this document are suspected pleas
e contact Tynetec’s customer su
pport dept on 01670 352371.
With the door closed, swipe the PIR down the right hand side with the magnetic fob.
The display will show
Client Wandering
and the sensor 8 digit ID number (34xxxxxx).
Check the ID is correct, press the
key to select
Accept
then press
ENTER
.
Note: if another device has been picked-up press
ENTER
to
Reject
and try again.
The display will show
Flat
, use the
&
keys to choose the dwelling type.
Press the
key
to select
No: 000000
then press the
ENTER
key.
Use the
&
keys to select each digit of the flat number and the
&
keys
to
move between digits then press the
ENTER
key.
Press
key
several times to select
Exit
then press the
ENTER
key.
The display will prompt you to “
Trigger the Sensor
” again.
Swipe the PIR again and the display will show
Door Contacts
and the sensor 8 digit ID
number (58xxxxxx). Repeat the same procedure as above.
Note: the 2 alarms alternate with each swipe and they may transmit in reverse order.
Press
ENTER
to activate the wake-up display then
ENTER
again to display
the main menu.
Press
ENTER
to select
Radio Devices
Press
ENTER
to select
Learn Device
The display will prompt you to
“
Trigger the Sensor
”.
You now have 20 seconds to activate the property exit sensor.
From the
Learn Device
menu select
Exit
then press
ENTER
.
From the
Radio Devices
menu select
Exit
then press
ENTER
.
The display will return to the wake-up screen and go blank after 10 seconds.
The Altec Response is now back in normal operating mode.
tynetec