INSTALLATION AND OPERATING INSTRUCTIONS

4211-861-G    10-12-16                                                                                                                                                                                                                                                              7013545    314 SKSM 211 

B

Page 8

 
 
 
 
 
 
 
 

Shower

Sauna (10 - 15 min.)

Shower or swim

Rest (10 - 15 min.)

Relax with juice or water

You liked it?

Do it once again and

you will feel great.

     SECTION 8: HIGH LIMIT CONTROL (RESET BUTTON)

     SECTION 9: HOW TO TAKE A SAUNA

     SECTION 7: OPERATION, Continued

The sauna heater has a built-in high limit control, which automatically turns off the 
heater if the temperature inside in the sauna room rises to an abnormally high 
level.  

To restart the heater, let the heater cool, then push the reset button on the bottom 
of the heater, see Diagram 1. If the high limit continually shuts off the heater, refer 
to Section 14 for Troubleshooting.

• When taking a sauna, allow time to relax completely.
• Remove clothing and jewelry...if required, wear a towel loosely.
• After 10 minutes or when perspiration begins, leave sauna and relax in
   dressing    area...follow with a cool shower.
• Cooling time should equal time spent in sauna. Enter sauna room again
   and stay   5 or 10 minutes.
• Repeat the cycle 2 or 3 times; end with a brisk shower...rinse in cool
   water.
• Dress when completely dry and perspiration has stopped.
• Some sauna bathers enjoy the soothing effect of steam by splashing
   water on the heated   sauna rocks. Use only one dipper full (approx. ½
   cup) at a time and keep   clear of the steam as it rises off the rocks.
• Do not smoke, exercise or drink alcoholic beverages in the sauna room.
• Do not pour chlorinated pool or spa water on the heater or corrosion
   damage may result.

SET  TIME  OF  BATH:    (Defaulted  to  the  maximum  of  1  hour)  Move  your  hand  in 
front  of  the  screen.  Press  "down"  arrow  until  "TIMER"  is  on  screen,  press  OK. 
"BATH  TIME  LIMIT"  will  appear  and  press  OK.  Press  up  or  down  arrow  to  set 
correct number, press "OK" to advance to next number for desired time to start to 
heat the sauna. Press "OK" to accept bath time and press "HOME" icon.
 
START  HEAT  IMMEDIATELY:  Ensure  the  "clock"  icon  is  not  displayed  on  screen. 
Press  "Home"  icon  and  press  "OK".  System  will  start  immediately.  The  "ON/OFF" 
icon will display indicating the system is heating. After 10 seconds the control will 
display program settings with the room temperature or press the "BACK ARROW" 
to display program settings.

TIME DELAY START TIME:  Move your hand in front of the screen. Press "down" 
arrow  until  "TIMER"  is  on  screen,  press  OK.  Press  "down"  arrow  until  "START 
TIME"  is  on  screen,  press  OK.  Press  up  or  down  arrow  to  set  correct  number, 
press "OK" to advance to next number for desired time to start to heat the sauna. 
Press "OK" to accept time and a clock will display on screen.

TIME  DELAY  DEACTIVATE:  Move  your  hand  in  front  of  the  screen.  Press  "down" 
arrow  until  "TIMER"  is  on  screen,  press  OK.  Press  "down"  arrow  until 
"DEACTIVATE" is on screen, press OK. A clock will disappear from the screen.

Summary of Contents for 1601-27

Page 1: ...th T1 Control Model 1601 27 Read all instructions carefully before installation Please leave all instructions and warranty with the owner WARNING Prolonged exposure to elevated temperatures is capable of inducing hyperthermia Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an incr...

Page 2: ...or lighting DIAGRAM 2 OBSERVING MINIMUM DISTANCES IS REQUIRED TO REDUCE THE RISK OF WIRE SIZE Floor Area Ceiling Height Volume Cu Ft Ceiling Height Volume Cu Ft Power Supply to Heater 1 208 21 6 2 10AWG GR 1 240 18 8 2 10AWG GR 3 208 12 5 3 12AWG GR 3 240 10 8 3 12AWG GR 1 208 28 8 2 8AWG GR 1 240 25 2 10AWG GR 3 208 16 7 3 12AWG GR 3 240 14 4 3 12AWG GR 1 208 38 5 2 8AWG GR 1 240 33 3 2 8AWG GR 3...

Page 3: ...void warranty Electric Shock Hazard High voltage exists within this equipment There are no user serviceable parts in this equipment All installation and service to this equipment should be performed by quali ed licensed personnel in accordance with local and national codes Do not construct sauna room so as to restrict air ow through the bottom of the heater Packing the rocks too tightly may cause ...

Page 4: ...ert screwdriver tip here to unsnap sensor cover from sensor Note vertical orientation of cover before removing Sensor protective cover Locate top of sensor 2 from ceiling and directly above of heater Heater Input Power Minimum ceiling spacing 15 Low Voltage Ethernet cable provided with control tongue and groove 2x4 supports T1 Control Sensor Wire Light Output Power Light Input Power Diagram 4 was ...

Page 5: ... 13 K6 Back Element 14 K3 Middle Element 15 K8 Front Element 16 K2 Light 3 step thermostat K8 turns off at 2c of set point K3 turns off at set point K6 turns off at 2c of set point Testing Procedure Lead 12 to 13 0 VDC relay closed 12 VDC relay open Lead 12 to 14 0 VDC relay closed 12 VDC relay open Lead 12 to 15 0 VDC relay closed 12 VDC relay open Lead 12 to 16 0 VDC relay closed 12 VDC relay open ...

Page 6: ... 13 K6 Back Element 14 K3 Middle Element 15 K8 Front Element 16 K2 Light 3 step thermostat K8 turns off at 2c of set point K3 turns off at set point K6 turns off at 2c of set point Testing Procedure Lead 12 to 13 0 VDC relay closed 12 VDC relay open Lead 12 to 14 0 VDC relay closed 12 VDC relay open Lead 12 to 15 0 VDC relay closed 12 VDC relay open Lead 12 to 16 0 VDC relay closed 12 VDC relay open ...

Page 7: ... switch location to the heater Do not use staples to secure the low voltage cable it may damage the cable Connect the control wires to the wires in the wall with the quick couplers Insert the extra length of wire in the wall Remove the adhesive tape from the back of the the T1 Control place the control so the hole for the retainer screw is facing downwards insert control into the wall and press th...

Page 8: ...prox cup at a time and keep clear of the steam as it rises off the rocks Do not smoke exercise or drink alcoholic beverages in the sauna room Do not pour chlorinated pool or spa water on the heater or corrosion damage may result SET TIME OF BATH Defaulted to the maximum of 1 hour Move your hand in front of the screen Press down arrow until TIMER is on screen press OK BATH TIME LIMIT will appear an...

Page 9: ... reduce cycling of the heater b Rocks must be placed between the elements and the wall of the rock compartment Incorrect Placement of Rocks a Loosely place rocks between the elements so air ow is not restricted Rock Grate Wall Bracket Minimum Dimensions 1 Put smaller rocks in rst around the outer perimeter of the heating chamber 2 Completely ll all four sections front 2 center sections between ele...

Page 10: ...el The enclosed CAUTION Reduce the risk of re caution plate must be mounted on the interior wall above the heater The heater should not be operated without its container properly lled with rocks and the rock guard in place If an intercom speaker is installed it should be away from the heater and as close to the oor as possible If a room light is installed it should be a surface mounted bracket typ...

Page 11: ...led rocks replaced To clean and remove perspiration stains use soap or detergent in warm water best applied with a scrub brush Badly soiled surfaces may require sanding Sand paper wrapped around a wooden block works well Benches and supporting structure must be inspected annually for potential deterioration due to age dry rot or abuse Any boards with signs of deteriorations should be replaced imme...