The following tables depict the wiring diagram of straight-through and crossover cabling. The
crossover cables simply cross-connect the transmit lines at each end to the receive lines at the
opposite end.
Straight-through Cabling
Pin 1
Pin 1
Pin 2
Pin 2
Pin 3
Pin 3
Pin 6
Pin 6
Cross-over Cabling
Pin 1
Pin 3
Pin 2
Pin 6
Pin 3
Pin 1
Pin 6
Pin 2
Connect an Ethernet cable into any switch port and connect the other side to your attached device.
The green or yellow Link/Act LED will light up when the cable is correctly connected. Refer to the
LED Indicator section for descriptions of each LED indicator.
If a port LED is off, go back and check for connectivity problems between that port and the network
device it is connected to.
The maximum cable length for 10/100BaseT with Cat 5 twisted pair cables is typically 100 meters
(328 ft.).
3. Network Application
The PoE Switch can receive power from PoE midspan and provide power to the PD. It will power
802.3af compliant devices if it is powered at 48VDC although it will not perform the 802.3af
handshake with the client device. The PoE Switch can be installed in a more appropriate position