Panel Description:

 

 

 

 
 
 

Item 

Name 

Descriptions 

POE : 

PoE power input indicator: the LED lights when the PoE input jack 
(the lower jack) has 18V~57V input. 

SOL : 

Solar power input indicator: the LED lights when SOL terminal is 
connecting to a solar panel and the solar panel input voltage is over 
12V. 

CHA : 

Charging indicator: the LED lights when  BAT terminal  is connected 
to battery and charging 

LOA : 

Loading indicator: the LED lights when the rear panel output 
terminal is connecting to a device and offering power. 
The LED always on when power ready. 

REV : 

Battery polarity reverse indicator: the LED lights when the battery 
polarities are reversed. (detail description see Sec. 5.1 

IN : 

PoE Input Jack: the lower RJ45 jack, used for PoE input. Allowed 
input voltage 18~57V 

OUT : 

PoE Output Jack: the upper RJ45 jack, used for PoE output; Output 
voltage depends on what model you selected. 

Fuse 

Fuse: for output over current protection, limiting the battery output 
current <= 10A. (If solar panel or PoE source is installed before the 
battery, and if the polarities of battery are reversed, then the fuse will 
be burnt.) 

SOL : 

Solar Panel Terminal: used to connect the solar panel. 

10 

BAT : 

Battery terminal: used to connect the battery.  
NOTE:  ALWAYS CONNECT THIS TERMINAL FIRST AND 
DISCONNECT LAST.
 

11 

LOA : 

Load Terminal:   The output voltage is the same as battery voltage. 
Maximum voltage clamped at 12.5V. 

Reviews: