Tyco Visonic SD-304C PG2 Installation Instructions Manual Download Page 4

 

D-304286 SD-304C PG2 Installation Instructions 

3. LOCAL DIAGNOSTICS TEST 

Bef ore testing, separate the base f rom the cover (see  Figure 3). 

A.

  Press the tamper switch once and release  it.

 

 

B.

  Put  back  the  cover  to  return  the  tamper  switch  to its normal (undisturbed) position, and then secure the f ront cover to the base with  the case 

closure screw. 

C.

  Use a  hammer  to apply shock in close proximity to the detector and verif y the red LED blinks, indicating  detection. 

D. 

Af ter 2 seconds the LED blinks 3 times.  
The  f ollowing table indicates received signal strength indication.  

LED response

 

Reception

  

 

Green  LED blinks

 

Strong

  

 

Orange  LED blinks

 

Good

  

 

Red LED blinks

 

Poor

  

 

No blinks

 

No communication

 

IMPORTANT!  Reliable  reception  must  be  assured.  Therefore,  "poor"  signal  strength  is  not  acceptable.  If  you  receive  a  "poor"  signal  from  the 
device, re-locate  it and  re-test until a  "good" or  "strong" signal  strength  is received.

 

Note:  For detailed  Diagnostics Test instructions, refer  to the control  panel  Installer Guide

4. EVENT INDICATIONS 

LED Indications 

Event 

Red LED ON 0.2  sec. 

Tamper  open / close 

Red on 2 sec. 

Shock  

Red on 2 sec. 

Open close door  

Red on 2 sec. 

Open close Aux input  

Yellow LED on  

AM detection 

– diagnostic mode 

Yellow LED blinks slowly (0.2 sec. ON,  30 sec. OFF) 

AM detection 

– Normal mode 

5. MISCELLANEOUS COMMENTS 

Visonic  Ltd.  wireless  systems  are  very  reliable  and  are  tested  to  high  st andards.  However,  due  to  low  transmitting  power  and  limited  range 
(required  by FCC  and other regulatory authorities), there  are  some limitations to be considered:  

A.

  Receivers  may be blocked by radio signals occurring on or near  their  operating f requencies , regardless of  the digital code used. 

B.

  A receiver  responds only to one transmitted signal at a time.  

C.

  Wireless  devices should be tested regularly  to determine  whether  there  are  sources of  interf erence and to protect against f au lts. 

6. COMPLIANCE WITH STANDARDS 

Compliance  with  Standards 

The  SD-304C  PG2  complies with the f ollowing standards: 

  

 

 

Europe: 

EN  301  489-3,  EN  50130-4,  EN  300  220-2,  EN  62368-1,  EN  50131-5-3,  EN  50130-5,  EN  50131-1, 

EN 50131-6  Type C, EN 50131-2-8,  EN 50131-2-6,  Grade  2, Class II. 
Certif ied by Applica Test & Certif ication AS in accordance with EN  50131-2-6  EN 50131-2-8,  EN  50131-5-3, 
EN 50131-6,  EN 50130-4,  EN 50130-5. 

UK:

  This  product is suitable f or use in systems installed to c onf orm to PD6662  

USA: 

CFR  47  part 15 (FCC) 

Canada:

  RSS-247,  RSS-102 

Hereby, Visonic Ltd. declares that the radio equipment type SD -304C  PG2 is in compliance with Directive 

2014/53/EU.  The  f ull text of  the EU  declaration of  conf ormity is available at the f ollowing internet address:

 

http://www.visonic.com/download-center

.

 

This  device  complies  with  Part  15  of   the  FCC  Rules  and  with  ISED  license-exempt  RSS  standard(s). 
Operation is subject to the following two conditions: (1) This device may not cause harmf ul interf erenc e,  and  
(2)  this  device  must  accept  any  interf erence  received,  including  interf erence  that  may  cause  undesired 
operation. 

Le  present  appareil  est  conforme  aux  CNR  d'ISED  applicables  aux  appareils  radio  exempts  de 
licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire 
de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique 
subi, meme si le brouillage est susceptible d'en compromettre le  fonctionnement. 

 

To comply with FCC  and IC  RF exposure compliance requirements,  the device should be located at a 
distance of  at least 20 cm f rom all persons during normal  operation. The  antennas  used f or this product must 
not be co-located or operated in conjunction with any  other antenna  or transmitter. 
Le  dispositif doit être placé à une  distance d'au moins 20 cm à partir de toutes les personnes au  cours de son 
f onctionnement normal. Les antennes  utilisées pour ce produit ne doivent pas être situés ou exploités 
conjointement avec une autre  antenne  ou transmetteur. 
 
The  digital  circuitry  of   this  device  has  been  tested  and  f ound  to  comply  with  the  limit s  f or  a  Class  B  digital 
device,  pursuant  to  Part  15  of   the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection 
against  harmf ul  interf erence  in  residential  installations.  This  equipment  generates,  uses and can radiate radio 
f requency  energy  and,  if   not  installed  and  used  in  accordance  with  the  instructions,  may  cause  harmf ul 
interf erence  to  radio  and  television  reception.  However,  there  is  no  guarantee  that  i nterf erence  will  not occur 