Tyco SD-304C PG2 Installation Instructions Manual Download Page 4

D-304286 SD-304C PG2 Installation Instructions

3. LOCAL DIAGNOSTICS TEST

Before testing, separate the base from the cover (see Figure 3). 

A.

Press the tamper switch once and release it.

B.

Put back the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front cover to the base with the case
closure screw.

C.

Use a hammer to apply shock in close proximity to the detector and verify the red LED blinks, indicating detection.

D.

After 2 seconds the LED blinks 3 times.
The following table indicates received signal strength indication.

LED response

Reception

 

Green LED blinks

Strong

 

Orange LED blinks

Good

Red LED blinks

Poor

 

No blinks

No communication

IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the device, 
re-locate it and re-test until a "good" or "strong" signal strength is received.

 

Note: For detailed Diagnostics Test instructions, refer to the control panel Installer Guide

4. EVENT INDICATIONS

LED Indications 

Event 

Red LED ON 0.2 sec. 

Tamper open / close 

Red on 2 sec. 

Shock 

Red on 2 sec. 

Open close door 

Red on 2 sec. 

Open close Aux input 

5. MISCELLANEOUS COMMENTS

Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due to low transmitting power and limited range (required 
by FCC and other regulatory authorities), there are some limitations to be considered: 

A.

Receivers may be blocked by radio signals occurring on or near their operating frequencies, regardless of the digital code used.

B.

A receiver responds only to one transmitted signal at a time.

C.

Wireless devices should be tested regularly to determine whether there are sources of interference and to protect against faults.

6. COMPLIANCE WITH STANDARDS

Compliance with Standards 

The SD-304C PG2 complies with the following standards: 

Europe: 

EN 301 489-3, EN 50130-4, EN 300 220-2, EN 62368-1, EN 50131-5-3, EN 50130-5, EN 50131-1, 

EN 50131-6 Type C, EN 50131-2-8, EN 50131-2-6, Grade 2, Class II. 
Certified by Applica Test & Certification AS in accordance with EN 50131-2-6 EN 50131-2-8, EN 50131-5-3, 
EN 50131-6, EN 50130-4, EN 50130-5. 

UK:

 This product is suitable for use in systems installed to conform to PD6662  

USA: 

CFR 47 part 15 (FCC) 

Canada:

 RSS-247, RSS-102 

Hereby, Visonic Ltd. declares that the radio equipment type SD-304C PG2 is in compliance with 

Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following 

internet address:

 

http://www.visonic.com/download-center

.

This  device  complies  with  Part  15  of  the  FCC  Rules  and  with  ISED  license-exempt  RSS  standard(s). 
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and 
(2) this  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired
operation.

Le  present  appareil  est  conforme  aux  CNR  d'ISED  applicables  aux  appareils  radio  exempts  de
licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire
de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique
subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.

To comply with FCC and IC RF exposure compliance requirements, the device should be located at a 
distance of at least 20 cm from all persons during normal operation. The antennas used for this product 
must not be co-located or operated in conjunction with any other antenna or transmitter. 
Le dispositif doit être placé à une distance d'au moins 20 cm à partir de toutes les personnes au cours de 
son fonctionnement normal. Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités 
conjointement avec une autre antenne ou transmetteur. 

The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in residential installations. This equipment generates, uses and can radiate radio 
frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the  instructions,  may  cause  harmful 
interference to radio and television reception. However, there is no guarantee that interference will not occur 
in a particular installation. If this device does cause such interference, which can be verified by turning the 
device  off  and  on,  the  user  is  encouraged  to  eliminate  the  interference  by  one  or  more  of  the  following 

Reviews: