LBI-38636S
21
Table 1 - Wire Line Installation Methods
METHOD
DESCRIPTION
PROCEDURE
ADVANTAGES OR
DISADVANTAGES
1
Single metallic pair (the
control currents are
simplexed to line, a two
wire cable is required).
a. Connect the metallic pair to
TB101-3 and -4.
b. Jumper P105-1 to P105-2,
and P104-1 to P104-2 on the
Interface Board.
Economical: Dependable where earth
ground currents may be large or good
earth grounds cannot be obtained. The
keying clicks will be heard on parallel
remotes.
2
Single metallic pair (the
control currents are
simplexed line to earth
ground, a two wire cable
is required).
a. Connect the metallic pair to
TB101-3 and -4.
b. Jumper P105-1 to P105-2 to
P104-1 on the Interface
Board and connect TB101-6
to earth ground.
Economical: Minimizes keying clicks in
paralleled remotes but large ground
currents may result in interference with
control function if located near sub-
stations.
3
One voice grade circuit
for bi-directional audio
and the other a metallic
pair of control voltages.
a. Connect audio pair to
TB101-3 and TB101-4.
b. Remove jumpers from P104
and P105 on Interface Board.
c. Connect control metallic pair
to TB101-1 and -6 on
Interface Board.
Provides excellent performance by
eliminating keying clicks and providing
no path for ground loop current, but
requires two pair.
4
Single metallic pair for
transmit audio and
control Currents. Single
voice grade circuit for
receive audio. A four
wire line is required.
a. Connect the transmit metallic
pair to TB101-2 and -5 on
Interface Board.
b. Connect a jumper from
P104-3 to P104-2, and P105-
3 to P105-2.
c. Connect the remote receive
pair to TB101-3 and -4
Provides full duplex operation in which
the remote can operate in receive and
transmit simultaneously. But, requires
two pair.
Figure 7 - Typical E & M Signaling Application
Summary of Contents for Mastr III
Page 1: ...Installation Manual LBI 38636S MASTR III Conventional Base Station...
Page 15: ...LBI 38636S 16...
Page 29: ...LBI 38636S 30...
Page 30: ...LBI 38636S 31...
Page 31: ...LBI 38636S 32 Figure 16 T R Shelf Interface Board...
Page 32: ...LBI 38636S 33...
Page 33: ...LBI 38636S 34...
Page 34: ...LBI 38636S 35 Figure 17 T R Shelf Interface Board Rev A...
Page 35: ...LBI 38636S 36...
Page 36: ...LBI 38636S 37...
Page 37: ...LBI 38636S 38 Figure 18 T R Shelf Interface Board Rev C...
Page 42: ...LBI 38636S 43 This Page Intentionally Blank...
Page 46: ...LBI 38636S INTERCONNECTION DIAGRAM 38 MASTR III STATION GETC VG INTERCONNECT 19D904268 Rev 4...
Page 47: ...INTERCONNECTION DIAGRAM LBI 38636S 39 MASTR III STATION SCAT 188D5683 Rev 2...