background image

 

D-306042 WK160 

User’s Guide 

17

 

 

LIMITED WARRANTY 

 

Digital Security Controls (DSC) warrants that for a 
period of 12 months from the the product shall be 
free of defects in materials and workmanship under 
normal use and that in fulfillment of any breach of 
such warranty, DSC shall, at its option, repair or 
replace the defective equipment upon return of the 
equipment to its repair depot. This warranty applies 
only to defects in parts and workmanship and not to 
damage incurred in shipping or handling, or damage 
due to causes beyond the control of Digital Security 
Controls such as lightning, excessive voltage, 
mechanical shock, water damage, or damage arising 
out of abuse, alteration or improper application of the 
equipment. 

 

 

Digital Security Controls (DSC) warrants that for a 
period of 12 months from the date of purchase, the 
product shall be free of defects in materials and 
workmanship under normal use and that in fulfillment 
of any breach of such warranty, DSC shall, at its 
option, repair or replace the defective equipment 
upon return of the equipment to its repair depot. This 
warranty applies only to defects in parts and 
workmanship and not to damage incurred in shipping 
or handling, or damage due to causes beyond the 
control of Digital Security Controls such as lightning, 
excessive voltage, mechanical shock, water damage, 
or damage arising out of abuse, alteration or 
improper application of the equipment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for DSC WK160

Page 1: ...ng Options 4 2 4 Enrolling the WK160 6 2 5 Configuring the WK160 Parameters 6 2 6 Enrolling Proximity Tags 8 3 USING THE TOUCH SCREEN KEYPROX 9 3 1 Arming and Disarming the System 9 3 2 Initiating Ala...

Page 2: ...e WK160 can be wall mounted using the supplied bracket or be used as a portable unit For compliance with various international standards the WK160 is equipped with two tamper switches that can be defi...

Page 3: ...incorrect type Dispose of used battery according to manufacturer s instructions Figure 1 Battery Insertion Insert two 1 5V batteries in each slot while ensuring battery polarity 2 2 Closing Battery C...

Page 4: ...Mounting part b A Tamper B DC Power Connection 2 3 Wall Mounting Options The WK160 unit mounting options are illustrated in the following drawings Wall Mounting Figure 4a Wall Mounting 1 Drill 3 moun...

Page 5: ...Mounting with External Electrical Connector Figure 4b Wall Mounting with External Electrical Connector 1 Secure bracket with 2 screws as shown in the two drawings above 2 Attach the unit to the bracke...

Page 6: ...ready enrolled you can configure the WK160 parameters via the Modify Devices option see Step 2 2 5 Configuring the WK160 Parameters Enter the main menu in the WP8010 30 control panel choose the number...

Page 7: ...Note For UL Listed product set to ON Define the volume level of the sounder Option settings Medium default Maximum and Minimum Note For UL Listed product the sounder cannot be used as the only annunci...

Page 8: ...h the WP8010 30 control panel as described in the corresponding section of the control panel s User or Installer Guide Each proximity tag corresponds to its User Code Therefore be sure that a correspo...

Page 9: ...enabled 2 sec Optional 4 INSTANT After arming HOME AWAY 5 7 LATCHKEY After arming AWAY 6 7 Notes 1 If Partition is disabled at the control panel skip Step 1 2 If Partition is enabled at the control p...

Page 10: ...conds the WK160 sends the command Fire alarm 2 sec See section 3 3 Panic alarm 2 sec See section 3 3 When pressing the Fire and Emergency icons together the WK160 starts beeping After pressing the but...

Page 11: ...on indication is displayed concurrently with the second partition key LED and then the third partition indication is similarly displayed General Indications The Ready Not Ready Alarm Memory Trouble an...

Page 12: ...ion system has an active trouble status that needs to be reviewed and cleared 3 AC failure Communication failure WK160 is out of range of the control panel or did not get an acknowledge signal of a co...

Page 13: ...s that are assigned to a Partition press the desired Partition number followed by the key Upon each press of the key the next zone number assigned to the pressed Partition number appears on the Zone d...

Page 14: ...X 10 output functions see the corresponding sections of the control panel s Installer Guide OUTPUTS menu and User Guide SCHEDULER menu Step X 10 device ON PGM device ON X 10 or PGM device OFF X 10 or...

Page 15: ...Low Battery Threshold 3 8 V Power source optional 5 12VDC Back light Blue white or black white Operating Temperature 0 C to 55 C 32 F to 131 F Note For UL Listed product the ambient temperature is 32...

Page 16: ...operation The antennas used for this product must not be co located or operated in conjunction with any other antenna or transmitter The portable device version complies with FCC and IC RF radiation...

Page 17: ...ge mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment Digital Security Controls DSC warrants that for a period of 12 months from the date...

Page 18: ...18 D 306042 WK160 User s Guide 2016 Tyco International Ltd and its Respective Companies All Rights Reserved Toronto Canada www dsc com Printed in Israel D 306042 Rev 01 02 16...

Reviews: