background image

2

Figure 1

HEC-12EC PRO

Finished Ceiling

Finished Wall

Closure Plate (Optional)

Rigid Support Collar with Hex Bolt (to

prevent movement of sprinkler head

away from  finished wall surface)

Retaining Collar

Branch

Line Fitting

1" N.P.T. Steel Nipple

1" x 1/2" N.P.T. Reducer

Escutcheon

Tamper-Resistant Screw

1/2"

1/4" 

±

 1/16"

3/4"

2 3/4"

3/8"

A

2 1/4" Dia. Hole in Wall

2 1/2" Escutcheon

4 1/2" Dia. (Security Closure Plate)

3 5/8" Dia. (Escutcheon Closure Plate)

1 7/16" 

±

 1/16" No Closure Plate

1 3/8" 

±

 1/16" Escutcheon Closure Plate

1 5/16" 

±

 1/16" Security Closure Plate

Note:  The special tamper-proof socket must be used for installation or removal of the tamper-resistant retaining screws.

Rigid Support Collar with Bolt
(Part #162-018-01)

Tamper-proof Socket
(Part #160-07-000)

Omega HEC Sprinkler Wrench
(Part #15932000)

OBSOLETE

Summary of Contents for CENTRAL Omega HEC-12EC PRO

Page 1: ...r pressure to force the orifice sealing mechanism and deflector assembly open Water is then discharged in a designed flow pattern The Omega ProhibitorTM Model HEC 12EC PRO Automatic Sprinklers have been specifically designed for use in institutional occupancies such as correctional facilities and mental health facilities where the occupants may attempt to tamper with or otherwise employ the sprink...

Page 2: ...w 1 2 1 4 1 16 3 4 2 3 4 3 8 A 2 1 4 Dia Hole in Wall 2 1 2 Escutcheon 4 1 2 Dia Security Closure Plate 3 5 8 Dia Escutcheon Closure Plate 1 7 16 1 16 No Closure Plate 1 3 8 1 16 Escutcheon Closure Plate 1 5 16 1 16 Security Closure Plate Note The special tamper proof socket must be used for installation or removal of the tamper resistant retaining screws Rigid Support Collar with Bolt Part 162 01...

Page 3: ...brass chrome plated white painted Security Closure Plate chrome plated brass plated white painted Length 23 8 60 3 mm Width 2 50 8 mm Weight 6 8 oz 193 grams ProhibitorTM sprinklers must be installed in accordance with current NFPA 13 Deviations from these requirements and standards or any alteration to the sprinkler itself will void any warranty made by Central Sprinkler Company In addition insta...

Page 4: ...ket Caution Special care must be taken when installing with a CPVC system Sprinklers must be installed after the manufacturer s recommended setting time for the primer and cement to ensure that neither accumulate within the sprinkler Special care must be taken when installing with a copper system Sprinklers must be installed only after the inside of the sprinkler nipple and associated fittings hav...