1. Disassemble the upper tooling assembly and 
removal blade assembly by unscrewing the 
extraction screw.

2. Insert the removal blade assembly into the 
receptacle. See Figure 3.

Figure 3

3. Properly orient the side plate(s) of the upper 
tooling assembly based on any adjacent receptacle 
assembly(s). See Figure 2.

4. Position the upper tooling assembly over the pins 
in the blade removal assembly. Lower the upper 
tooling assembly until the side plates contact the pc 
board. See Figure 4.

Figure 4

5. Tighten the extraction screw to remove the 
receptacle assembly from the pc board. See
Figure 5.

4. MAINTENANCE AND INSPECTION

It is recommended that the tool be inspected 
immediately upon its arrival to ensure that it has not 
been damaged during shipment.

Figure 5

4.1. Daily Maintenance

It is recommended that each operator be made aware 
of, and responsible for, the following steps of daily 
maintenance:

1. Remove dust, moisture, and other contaminants 
with a clean, soft brush, or lint-free cloth. DO NOT 
use objects that could damage the tool or any of its 
components.

2. When the tool is not in use, store it in a clean, dry 
area.

4.2. Periodic Inspection

Regular inspections should be performed by quality 
control personnel. A record of scheduled inspections 
should remain with the tool or be supplied to personnel 
responsible for the tool. The inspection frequency 
should be based on the amount of use, working 
conditions, operator training and skill, and established 
company standards.

5. REPLACEMENT AND REPAIR

Order tools through your representative, or call
1-800-526-5142, or send a facsimile of your purchase 
order to 717-986-7605, or write to:

     CUSTOMER SERVICE (038-035)
     TYCO ELECTRONICS CORPORATION
     PO BOX 3608
     HARRISBURG PA 17105-3608

For customer repair service, call 1-800-526-5136.

6. REVISION SUMMARY

Initial release of document