background image

408-8808

1U 24-Port Patch PanelDrawer 1933443-1

Rev C

4 of 4

Tyco Electronics Corporation

3. Slide the tray into the cover until the push tabs
“click” onto the cover. Make sure that there are no
fibers pinched between the cover and the tray.
Refer to Figure 6.

Figure 6

Interface Housing

Label Plate

Drawer Shown

Front Mounted

Push Tab

(2 Places)

4. REPLACEMENT AND REPAIR

DO NOT use any damaged or defective housings.
DO NOT disassemble any of the housings.

The drawers, interface housings, and jack SL
housings are not repairable if damaged. Order
additional drawers, interface housings, or jack SL
housings through your representative, or call
1–800–526–5142, or send a facsimile of your
purchase order to 1–717–986–7605, or write to:

CUSTOMER SERVICE (038–035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105–3608

5. REVISION SUMMARY

Revisions to this instruction sheet include:

S

Updated document to corporate requirements

S

Superceded drawer part number

S

Modified Figure 1 and Section 2

Summary of Contents for AMP NETCONNECT AMPTRAC 1933443-1

Page 1: ... website at www ampnetconnect com Reasons for reissue of this instruction sheet are provided in Section 5 REVISION SUMMARY 2 DESCRIPTION Figure 1 Each drawer consists of a cover and a tray The cover features two mounting brackets with four 6 32 screws and four washers Included are four 12 24 and four 10 32 cross recessed screws for mounting the drawer to the rack or equipment cabinet The tray feat...

Page 2: ...kit onto the tray according to the following 1 Attach one network saddle to each arm of the spider 2 Remove the backing from the self adhesive tape on the spider Firmly press the spider onto the inside of the tray preferably in the center and at one side of the tray 3 Repeat this procedure for the remaining spider placing it preferably in the center and at the other side of the tray Figure 3 Spide...

Page 3: ... the tray and position the jacket over one of the cable tie down bars Using the cable ties secure the cable to the bar Follow this procedure for the remaining cable 3 Separate the first group of fibers to be located on the first two interface housings and or cassettes 4 Join the connectors to the jack SL housings or coupling bushings at the back of the interface housings and or cassettes See Figur...

Page 4: ...defective housings DO NOT disassemble any of the housings The drawers interface housings and jack SL housings are not repairable if damaged Order additional drawers interface housings or jack SL housings through your representative or call 1 800 526 5142 or send a facsimile of your purchase order to 1 717 986 7605 or write to CUSTOMER SERVICE 038 035 TYCO ELECTRONICS CORPORATION PO BOX 3608 HARRIS...

Reviews: