Instruction Sheet

408-8808

AMP NETCONNECT* AMPTRAC

1U 24-Port Patch Panel Drawer

LOC B

1 of 4

E2008 Tyco Electronics Corporation, Harrisburg, PA

All International Rights Reserved

TE logo and Tyco Electronics are trademarks.

*Trademark. Other products, logos, and company names used are the property of their respective owners.

TOOLING ASSISTANCE CENTER 1-800-722-1111

PRODUCTINFORMATION 1-800-522-6752

This controlled document is subject to change.

For latest revision and Regional Customer Service,

visit our website at www.tycoelectronics.com

11 SEP 08 Rev C

1933443-1

Figure 1

Cover

Mounting Bracket

(2 Places, Positioned for

Front Mounting)

Cable Tie-Down

Bar (4 Places)

Cable Exit

Opening

Tray

(Shown Out of Cover)

Push Tab

(2 Places)

1. INTRODUCTION

Patch Panel Drawer 1933443–1 is used for housing
singlemode and multimode fiber optic connections.
The drawer fits into a standard 483 mm [19 in.]
Electronic Industries Alliance (EIA) rack or equipment
cabinet. Read these instructions thoroughly before
starting installation.

Dimensions in this instruction sheet are in

millimeters [with inches in brackets]. Figures and

illustrations are for reference only and are not

drawnto scale.

To obtain information on AMP NETCONNECT
products, call PRODUCT INFORMATION at the
number at the bottom of this page, or visit the 
AMP NETCONNECT website at
www.ampnetconnect.com.

Reasons for reissue of this instruction sheet are
provided in Section 5, REVISION SUMMARY.

2. DESCRIPTION

(Figure 1)

Each drawer consists of a cover and a tray. The cover
features two mounting brackets (with four 6–32
screws and four washers). Included are four 12–24
and four 10–32 cross–recessed screws for mounting
the drawer to the rack or equipment cabinet.

The tray features two push tabs, four housing
openings, four cable tie–down bars, and a cable exit
opening. The bars are used for securing up to 24
pre–terminated cable to the tray (three releasable
wire ties are included for this use). When the tray is
closed, the push tabs “click” onto the cover to secure
the tray to the cover.

Also included is a cable management kit (containing
eight network saddles and two spiders). The kit is
used for facilitating cable routing within the tray.

The drawer accepts four 6–port front loadable
interface housings or cassettes (available separately).

3. INSTALLATION

3.1. Open the Tray

Simultaneously push both push tabs slightly inward,
and slide the tray open. To remove the tray from the
cover, slide the tray open until it stops, then tilt the
tray slightly up and out of the cover.

3.2. Mount the Enclosure

ALWAYS use safe lifting techniques. NEVER lift

more thanyou canmanage comfortably. Lifting

guidelines are available from the Occupational

Safety and Health Administration (OSHA).

1. Remove the tray from the cover, and set aside.

AMP NETCONNECT logo is a trademark of Tyco Electronics.

NOTE

i

CAUTION

!

Summary of Contents for AMP NETCONNECT AMPTRAC 1933443-1

Page 1: ... website at www ampnetconnect com Reasons for reissue of this instruction sheet are provided in Section 5 REVISION SUMMARY 2 DESCRIPTION Figure 1 Each drawer consists of a cover and a tray The cover features two mounting brackets with four 6 32 screws and four washers Included are four 12 24 and four 10 32 cross recessed screws for mounting the drawer to the rack or equipment cabinet The tray feat...

Page 2: ...kit onto the tray according to the following 1 Attach one network saddle to each arm of the spider 2 Remove the backing from the self adhesive tape on the spider Firmly press the spider onto the inside of the tray preferably in the center and at one side of the tray 3 Repeat this procedure for the remaining spider placing it preferably in the center and at the other side of the tray Figure 3 Spide...

Page 3: ... the tray and position the jacket over one of the cable tie down bars Using the cable ties secure the cable to the bar Follow this procedure for the remaining cable 3 Separate the first group of fibers to be located on the first two interface housings and or cassettes 4 Join the connectors to the jack SL housings or coupling bushings at the back of the interface housings and or cassettes See Figur...

Page 4: ...defective housings DO NOT disassemble any of the housings The drawers interface housings and jack SL housings are not repairable if damaged Order additional drawers interface housings or jack SL housings through your representative or call 1 800 526 5142 or send a facsimile of your purchase order to 1 717 986 7605 or write to CUSTOMER SERVICE 038 035 TYCO ELECTRONICS CORPORATION PO BOX 3608 HARRIS...

Reviews: