Programming The Switch
The switch can be controlled using a PC via the front panel RS232
console port and the supplied cable. When the connection
between Switch and PC is complete, turn on the PC and run a
terminal emulation program such as HyperTerminal and configure
its communication parameters to match the following default
characteristics of the console port:.
Com 1 or Com 2
Baud Rate = 9600 bps
Data Bits = 8
Parity = None
Stop Bits = 1
Flow Control = None
Figure 3. Settings the PC
communication parameters
Press <CR> return key several times to view the main start-up
screen. There are five key controls in the main menu:
Figure 4 - Main Menu Screen
(P) = Port State lists the status and settings of the selected port(s)
(V) = Port based VLAN settings
(Q) = Port based QoS settings
(D) = Restore factory default settings
(R) = Reset the switch