background image

Instruction Sheet

Terminating Head 58062- 1

For AMPMODU* Mass Termination (MT)

408--9085

LOC B

1

of 5

E

2010 Tyco Electronics Corporation, Harrisburg, PA

All International Rights Reserved

TE logo and Tyco Electronics are trademarks.

*Trademark. Other products, logos, and company names used are the property of their respective owners.

TOOLING ASSISTANCE CENTER 1--800--722--1111

PRODUCT INFORMATION 1--800--522--6752

This controlled document is subject to change.

For latest revision and Regional Customer Service,

visit our website at

www.tycoelectronics.com

04 FEB 10 Rev B

Receptacle Connectors

Figure 1

Channel

Ramp

Feed Channel

Slot

Wire Inserter

Adjuster

(Inserter Rod)

Anti--Backup Pawl

(Not Shown)

Feed Slide

(Not Shown)

Wire Guide

Note:

Adapter for Single--Row

Connectors Not Shown

1. INTRODUCTION

Terminating Head 58062--1 is designed to terminate

unstripped

discrete wire sizes 30 through 20 AWG

onto AMPMODU MT receptacle connectors having a

single row (reference part number 1--102747--7) or

double row (reference part number 102393--1)

of contacts with spacing on 2.54

¢

2.54 mm

[100

¢

100 in.] centerlines.

The head must be used with one of the following

power units (for operating procedure, refer to the

instructions packaged with the power unit).

Power Unit

Instruction Sheet (408) or

Customer Manual (409)

Pistol Grip Manual Handle

Assembly 58074--1

408--6790

Pistol Grip Pneumatic Handle

Assembly 58075--1

408--6789

Pneumatic Power Bench

Assembly 58338--1

408--9393

Electric Power Unit 931800--1

409--5746

Dimensions in this instruction sheet are in

millimeters [with inches in brackets]. Figures are

not drawn to scale.

Reasons for reissue of this instruction sheet are

provided in Section 8, REVISION SUMMARY.

2. DESCRIPTION

(Figure 1)

Features of the head and their function are as follows:
Wire inserter—forces the wire into the slotted beams

of the contact.

Wire guide—holds the connector properly in relation

to the wire.

Adjuster (inserter rod)—is a piston for, and regulates

the travel of, the wire inserter.

Feed slide—automatically advances the connector

after each termination.

Anti--backup pawl—prevents the connector from

moving out of position after it has been advanced by

the feed slide.

An adapter is included with the head that must be

used for terminating single--row connectors.

After the head is installed onto the power unit, it

serves as a guide and support for the connector

during termination. The arrow on the top of the head

indicates the direction that the connector will move in

the head. The wires are terminated onto the

connector using the insulation displacement

technique.

3. SETUP

1. For single--row connectors, refer to Figures 1

and 2, and install the adapter onto the head as

follows:

a. Align the side of the adapter with the side of

the head so that the bottom starts at the slot

and the clip starts at the ramp.

b. Slide the adapter into the slot until the clip

drops into the channel.

2. Install the head onto the power unit according to

the instructions packaged with the power unit.

Make sure to observe any cautions and dangers.

NOTE

i

Reviews: