![Tyco Electronics 549043-1 Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/tyco-electronics/549043-1/549043-1_operating-instructions-manual_1186222013.webp)
Page 13 / 17 ECOC: EGC0 ; LOC: AI
PN 8-744013-1
412-18911 Rev.A
If you suspect that the tool cannot be operated safely, it must be switched off and secured against anyone
accidentally switching it on.
The tool may only be used for the purpose specified in the operating manual.
The manufacturers and suppliers will not be liable for any damages which may result due to the tool being
used for a purpose other than that for which it was intended. This is done entirely at the user’s own risk.
2.3 Notes on service and maintenance
It is absolutely essential that tool and equipment parts on which maintenance or service jobs have to be
carried out are disconnected from the electricity supply, unless anything to the contrary is stated in the
operating manual.
The disconnected parts must first be checked to ensure that they no longer carry any current; then they
must be earthed and short-circuited. Adjacent parts carrying current must be insulated.
The electrical equipment of the tool must be checked regularly, faults such as loose connections or
scorched cables must be removed immediately.
If it should be necessary to carry out work on parts which carry current, it is important to engage the
assistance of a second person who, in cases of emergency, can operate the emergency stop or the main
switch or can cut off the electricity supply to the tool. Only insulated tools should be used!
3 Intended use
The Pistol-Grip tool with the PN 549043-1 is used to process micro magnet wire connectors. The different
variants of the following basis numbers are to be used:
Socket PN 964320
Pin PN 964318
Figure 1
Figure 2