45° SHIELDS G4 WITH DRAKA CABLE
411-15684
Rev. O
3 to 4
2.2. Procedure for crimping the ferrule
Important
: This step has to be done before crimping the two shields legs.
Picture 4
When the part is ready, the ferrule must be crimp with two different kinds of set depending of
the ferrule side as indicated picture 5.
Picture 5
For the ‘cable side’ the crimp shape is an hexagon of 5.8mm high. The Connect Systems
die-set reference number is ‘190-5.8D’.
For the ‘Shield side’ the crimp shape is an oval of 8.2mm Width and 8.7mm High.
The Connect Systems die-set reference number is ‘190-8.2-8.7’.
The two crimp sets must work together
in one step
in the ‘
Reversed direction’
with
the
connector directed up
(direction defined picture 4 and 5). To ensure the good
crimp orientation “a go / no go” shape can be added under the connector position as
suggested picture 5.
Reversed
crimp direction
is shown by
the two red
arrows
Crimp
Width
‘Crimp
width’ and
‘crimp high’
used to
specify the
crimp set
shape.
Crimp
High
Preliminary definitions
Cable
Side
Shield Side
Proposition
of shape to
ensure the
good crimp
direction.
Connector
directed up