INTRODUCTION 

1.1. Objective 

This specification describes the mandatory procedure to be followed during the 
assembly of the harness with the 45° shields with 
Draka cable for  : 

a)  positioning the ferrule before crimping, 

b)  crimping the ferrule,  

c)  crimping the two upper shield legs down the lower shields. 

         

    

      

 

        WITH BRAID CABLE   

 

 

  WITH DRAKA CABLE 

 

1.2. Components 

a)  MQS socket housings 4 positions loaded with 3 contacts which are crimped on 

the cable wires according general recommendation  411-15677.  

Note

 

: either the “Draka cable” or the “braid cable”

 

are  self supplied by the customer. 

“Draka cable” reference number of  Draka Deutschland is FLR91XCC33X according 
specification data sheet number DF055-1999, issue B/24.08.00/Ve/Ot. 

  

b)  Ferrule (Tyco part number 0-953903-1) 

c)  Upper 45° shield assembly (Tyco part number 0-1379633-1) 

d)  Lower 45° shield assembly (Tyco part number 0-1379634-1) 

 