background image

http://www.tyan.com

 

 
 

 

 
 

TN52J-E3252 

 
 

Service Engineer’s Manual 

 
 
 
 
 
 

 

 

Summary of Contents for TN52J-E3252

Page 1: ...1 http www tyan com TN52J E3252 Service Engineer s Manual...

Page 2: ...en reviewed for accuracy and reliability prior to printing MiTAC assumes no liability whatsoever and disclaims any express or implied warranty relating to sale and or use of TYAN products including li...

Page 3: ...inst harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wi...

Page 4: ...an introduction to the TYAN TN52J E3252 storage system and standard part list describes the external components gives an overview of the product from different angles Chapter 2 Setting Up This chapte...

Page 5: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Page 6: ...l hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space...

Page 7: ...ock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety require...

Page 8: ...Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that...

Page 9: ...ing hazardous energy levels Do not exceed the level of repair specified in the procedures in the product documentation Improper repairs can create a safety hazard Allow the product to cool before remo...

Page 10: ...10 http www tyan com instructions...

Page 11: ...http www tyan com 11...

Page 12: ...0 1 Work Area 25 2 0 2 Tools 25 2 0 3 Precautions 26 2 1 Unpacking Checking the Equipment 27 2 1 1 Box Contents and Accessories 27 2 2 Installing Hard Drives 28 2 3 Rack Mounting 30 2 3 1 Installing t...

Page 13: ...ness environment It provides a maximum data protection and exceptional performance in a storage subsystem Target usage ranges are set from small business to departmental and corporate server needs The...

Page 14: ...put Range 100 240V AC 8 4A Frequency 50 60 Hz Output Watts 580 Watts Expander Controller board Expander Controller PMC PM8055 SXP 48X12G Connector 4 mini SAS HD connectors per IOM Connector configurat...

Page 15: ...t The following views show you the product from different angles 1 3 1 System Front View No Description 1 24 2 5 hot swappable HDD trays 2 Front User OP Panel NOTE A discrete HBA RAID adapter is requi...

Page 16: ...onds to illuminate system controlled LEDs All LEDs set to ON shall revert to previous state after 15 seconds elapsed 2 System Fault LED Amber Service Action Required 585 595nm OFF Normal operation no...

Page 17: ...a fault service action required in one of the IOM modules in the system Fast Blinking 2Hz at 50 duty cycle 250 ms ON 250 ms OFF Controller locate function 6 7 Segment LED Display Factory shipped defau...

Page 18: ...ice Action Required 585 595nm OFF Normal operation Steady ON System has detected a fault in the drive Fast Blink 2 Hz at 50 duty cycle 250 ms ON 250 ms OFF Drive locate HDD SSD Activity LED Green Okay...

Page 19: ...ntroller Module 0 IOM0 5 Power Supply Status Indicators Rear IO Placement No Description 1 Mini USB Debug Serial Port for service only 2 RJ45 Management LAN Port for service only 3 IOM System Summary...

Page 20: ...duty cycle 250 ms ON 250 ms OFF Enclosure ID Locate request either through chassis ID 2 System Fault LED Amber Service Action Required 585 595nm OFF Normal operation no service or fault states in sys...

Page 21: ...tem has taken IOM off line IOM is ready to remove or service action allowed 2 Controller Fault LED Amber Service Action Required 585 595nm OFF Normal operation Steady ON System has detected a fault in...

Page 22: ...3 7 SAS Port Indicators LED State Color Description 1 Fault LED One or more links failure amber ON Link not at 12G speed 2 Link Activity LED Link Off Line green OFF No cable present Link Ready green s...

Page 23: ...rmal operation 3 PSU Fan Fault LED Amber Internal PS Fan Service Action Required 585 595nm OFF No fault detected on internal power supply fan Steady ON System has detected a fault in the internal powe...

Page 24: ...http www tyan com 24 NOTE...

Page 25: ...0 2 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static pad Most of the electrical and mechanical conn...

Page 26: ...ips connectors and leads The Mid plane is pre installed in the system When removing the Mid plane always place it on a grounded anti static surface until you are ready to reinstall it Hold electronic...

Page 27: ...appear damaged contact your retailer or browse to TYAN s website for service http www tyan com The product should arrive packaged as illustrated below 2 1 1 Box Contents and Accessories TN52J E3252 C...

Page 28: ...drives Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack 1 Push the locking lever latch to pull the HDD tray out 2 Unscrew to remove the bracket from...

Page 29: ...http www tyan com 29 4 Reinsert the HDD tray into the chassis and press the locking lever latch to secure the HDD tray Repeat the same procedures to install other HDD trays...

Page 30: ...ly like the rackmount storage you purchased Therefore the illustrations should be held for your reference only After installing the necessary components the TYAN TN52J E3252 can be mounted in a rack u...

Page 31: ...http www tyan com 31 2 Lift the unit and then engage the sides of the unit with the installed side rails 1 Push the whole system into the rack 2 Secure the whole system to the rack with 4 screws...

Page 32: ...http www tyan com 32...

Page 33: ...r FW that supports share storage or other IN OUT port configurations 2 4 1 SAS In Out Port Configuration Volume Expansion Connect one end of the External mini SAS HD cable SFF 8644 to the HBA card por...

Page 34: ...http www tyan com 34 2 4 2 IO Port Connection...

Page 35: ...e power switch of RAID system NOTE RAID controller is required for RAID support This step is to ensure users to understand the sequence of turning off machines when a RAID system is involved in config...

Page 36: ...http www tyan com 36 NOTE...

Page 37: ...e to remove all PS modules and IOMs before you unscrew the chassis cover to lift it up 3 1 Replacing the Power Supply with Cooling Fan The system has two pre installed Power Supply Modules Please unpl...

Page 38: ...2 Replacing the IOM Follow the instructions to remove the I O Module IOM 1 Unlock the locking lever latch and pull the locking lever open 2 Slide to remove the old IOM Then install the new IOM all th...

Page 39: ...Removing the Cover Before replacing any parts you must remove the chassis cover Follow the instructions to remove the cover of the TN52J E3252 3 Remove all IOMs and PS Modules 4 Loosen 8 screw on the...

Page 40: ...http www tyan com 40 5 Slide the rear top cover to lift it up...

Page 41: ...n com 41 3 4 Replacing the Mid plane Follow these instructions to replace the Mid plane 1 Loosen 6 screws on the Mid plane 2 Push the Front Panel Connector latch to an open position 3 Unplug the Front...

Page 42: ...http www tyan com 42 4 After replacing a new Mid plane follow the procedures described earlier in reverse order to reinstall the Mid plane...

Page 43: ...icture Description Power Supply Fan FRU PS 0200 471100000310 580W PSU Fan Rack Mounting Parts FRU AS 0070 452T57300001 Rail Kit Cable FRU CS 0330 332810000514 AC Power Cord US type L 1800mm CCBL 0300...

Page 44: ...http www tyan com 44 NOTE...

Page 45: ...to and from computer storage devices such as hard drives and tape drives SES SCSI Enclosure Services Most SCSI enclosure products support this protocol Enclosure products can be communicated by using...

Page 46: ...http www tyan com 46 NOTE...

Page 47: ...s service beyond their expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive...

Page 48: ...oper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...

Reviews: