background image

 

http://www.tyan.com 

93 

5.3.1.1      Add an Attempt 

 

 
 
Read only. 

 

NOTE:

 

Only LAN1 supports iSCSI function. 

 
 

Summary of Contents for TN200-B7108

Page 1: ...1 http www tyan com TN200 B7108 Service Engineer s Manual...

Page 2: ...ing liability or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without no...

Page 3: ...se limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio freq...

Page 4: ...not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Disp...

Page 5: ...tional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter 4 Motherboard Information This chapter lis...

Page 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Page 7: ...The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning...

Page 8: ...nees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rac...

Page 9: ...l cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that are improperly matted with the rails might be unstable Verify t...

Page 10: ...your product Do not attempt to recharge the battery Dispose of used batteries according to the instructions of the manufacturer Do not dispose of batteries with the general household waste To forward...

Page 11: ...ect the product from the AC electrical outlet and refer servicing to an authorized service provider Examples of damage requiring service include The power cord extension cord or plug has been damaged...

Page 12: ...12 http www tyan com NOTE...

Page 13: ...37 2 1 4 Installing the Expansion Card 38 2 1 5 Removing the CPU Air Duct 40 2 1 6 Installing the CPU and Heatsink 41 2 1 7 Installing the Memory 44 2 1 8 Installing Hard Drives 47 2 1 9 Installing t...

Page 14: ...s 87 5 1 2 Getting Help 88 5 1 3 In Case of Problems 88 5 1 4 Setup Variations 88 5 2 Main Menu 89 5 3 Advanced Menu 90 5 3 1 iSCSI Configuration 92 5 3 2 Intel Virtual RAID on CPU 98 5 3 3 Trusted Co...

Page 15: ...Management 170 5 6 1 System Event Log 172 5 6 2 BMC Network Configuration 173 5 7 Security 174 5 7 1 Secure Boot 175 5 8 Boot 179 5 8 1 Delete Boot Option 181 5 9 Save Exit 182 Chapter 6 Diagnostics...

Page 16: ...http www tyan com 16 NOTE...

Page 17: ...200 B7108 server system is capable of offering scalable 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation The TN200 B7108 not only empowers your company...

Page 18: ...Tyan Barebone is defined by the following models B7108T200X4 220PV3HR Intel based platform B7108T200X4 220PE6HR Intel based platform SKU Comparison Table Model SKU HDD Bays TN200 B7108 B7108T200X4 220...

Page 19: ...ports 2 x USB2 0 1 x D SUB VGA ports w via cable per port External Drive Bay per blade Type Q ty 3 5 Hot Swap 3 Total 12 devices HDD backplane support 12 SAS 12Gb s SATA 6 0Gb s Supported HDD Interfa...

Page 20: ...ntel C621 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe M 2 connector 2 M 2 connector 22110 2280 by PCI E interface Graphic per blade Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspe...

Page 21: ...ice PXE via LAN Storage User Configurable FAN PWM Duty Cycle Console Redirection ACPI sleeping states S4 S5 ACPI 6 1 Power Supply Type RPSU Input Range 100 127V 200 240V 47 63Hz System 28A 12 6A max P...

Page 22: ...del TN200 Dimension D x W x H 3 42 x W17 43 x D34 02 H86 8mm x W442 8mm x D864mm Motherboard 4 S7108GMR 4 blades in one chassis Gross Weight 38 kg 84 lbs Board Dimension L521 1 x W171 x H2 4mm Blade D...

Page 23: ...nel 6 Channels per CPU Memory voltage 1 2V Expansion Slots per blade PCI E 1 PCI E Gen3 x8 slot 1 PCI E Gen3 x16 slot Pre install TYAN Riser Card M7108T200 L16 1L 1U PCI E x16 riser card left M7108T20...

Page 24: ...ade Onboard Chipset Onboard Aspeed AST2500 AST2500 IPMI Feature 24 bit high quality video compression 10 100 1000 Mb s MAC interface AST2500 iKVM Feature IPMI 2 0 compliant baseboard management contro...

Page 25: ...to our AVL support lists Regulation FCC SDoC Class A CE DoC Class A VCCI Class A CB LVD Yes RCM Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F...

Page 26: ...E24 B7108T200X4 220PE6HR SKU or M7108 HDBP U12 B7108T200X4 220PV3HR SKU 9 1 M7108 FB 10 2 M7108 HDBB B7108T200X4 220PE6HR SKU 11 4 M7108T200 L16 1L 12 4 M7108T200 R8 1L 13 2 M7108 HSCB B7108T200X4 220...

Page 27: ...www tyan com 27 1 5 About the Product The following sections show you the product from different views 1 5 1 System Front View NODE1 HDD 0 HDD 5 NODE2 HDD 6 HDD 11 NODE3 HDD 12 HDD 17 NODE4 HDD 18 HD...

Page 28: ...http www tyan com 28 NODE1 HDD 0 HDD 2 NODE2 HDD 3 HDD 5 NODE3 HDD 6 HDD 8 NODE4 HDD 9 HDD 11...

Page 29: ...Activity Blinking Off Drive Failure Off Solid On Drive Identify Blinking Blinking 1 Hz RAID Rebuild Blinking Blinking 4 Hz B7108T200X4 220PV3HR SKU 3 5 Device Drive State Activity LED Green Status LED...

Page 30: ...HH HL PCIE Gen3 x8 Slot 10Gbps LAN Port LAN Indication 10Gbps LAN Link Activity LED Scheme Left LED Link Activity LED Color Green Right LED Speed LED Color Yellow No Link OFF OFF 100 Mbps Link Green...

Page 31: ...mode 1Hz Blinking Green AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Amber Power supply warning events where the power supply continues to opera...

Page 32: ...ion 1 HDD Tray 2 Dual motor Fan1 3 Dual motor Fan2 4 Dual motor Fan3 5 Dual motor Fan4 6 M7108 PDB U Power Distribution Board top pre installed M7108 PDB L Power Distribution Board bottom pre installe...

Page 33: ...ccidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static...

Page 34: ...metal chassis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre install...

Page 35: ...section describes how to install components on to the motherboard including CPUs memory modules and Add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove TN200 B7108 chassi...

Page 36: ...these instructions to remove the computer blade from the chassis 1 Loosen the thumb screw securing the locking lever 2 Push the locking lever downwards to eject the computer blade slightly 3 Pull the...

Page 37: ...http www tyan com 37 2 1 3 Removing the Riser Card Bracket Follow these instructions to remove the Riser Card Brackets 1 Unscrew to lift up the Riser Card Brackets...

Page 38: ...the Riser Card Bracket 1 Refer to Section 2 1 3 Removing the Riser Card Bracket to lift up the Riser Card Brackets 2 Unscrew to take out the dummy bracket This Riser Card Bracket is pre installed wit...

Page 39: ...http www tyan com 39 4 Repeat the same procedures for the other Riser Card Bracket pre installed with M7108T200 R8 1L...

Page 40: ...http www tyan com 40 2 1 5 Removing the CPU Air Duct Follow the steps to remove the CPU air duct 1 Unscrew the CPU air duct 2 Push the CPU air duct slightly forwards to lift it up...

Page 41: ...ow the steps below on installing CPUs and CPU heatsinks 1 Align and install the processor on the carrier 2 Carefully flip the heatsink Then install the carrier assembly on the bottom of the heatsink a...

Page 42: ...n cap Locate the CPU socket s guide pin NOTE A new heatsink comes with pre applied thermal grease Once the heatsink has been removed from the processor you need to clean the processor and heatsink usi...

Page 43: ...n place the heatsink onto the top of the CPU socket 5 To secure the heatsink use a T30 Security Torx to tighten the screws in a sequential order 1 2 3 4 NOTE When disassembling the heatsink loosen the...

Page 44: ...odules onto the motherboard 1 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly...

Page 45: ...mmy unless the slots will be inserted with memory modules DIMM Location Recommended Memory Population Table Single CPU Installed CPU0 only Quantity of memory installed 1 2 3 4 5 6 7 8 P0_MC0_DIM_CH_A1...

Page 46: ...1_DIM_CH_E0 P0_MC1_DIM_CH_F0 P1_MC0_DIM_CH_A1 P1_MC0_DIM_CH_A0 P1_MC0_DIM_CH_B0 P1_MC0_DIM_CH_C0 P1_MC1_DIM_CH_D1 P1_MC1_DIM_CH_D0 P1_MC1_DIM_CH_E0 P1_MC1_DIM_CH_F0 NOTE 1 indicates a populated DIMM s...

Page 47: ...ons to install a hard drive Installing 3 5 HDD 1 Press the locking lever latch and pull the locking lever to the left to its OPEN position 2 Pull the locking lever to remove the HDD tray from the HDD...

Page 48: ...http www tyan com 48 4 Reinsert the HDD tray into the HDD cage...

Page 49: ...49 Installing 2 5 HDD 1 Take out the 2 5 HDD Adapting Holder for 3 5 HDD Bays FRU SM 0091 2 Align the 2 5 HDD with the 2 5 HDD Adapting Holder for 3 5 HDD Bays 3 Secure the 2 5 HDD to the Adapting Hol...

Page 50: ...http www tyan com 50 4 Slide the Adapting Holder into the 3 5 HDD Bay 5 Secure the Adapting Holder to the HDD Bay with 4 screws...

Page 51: ...http www tyan com 51 2 1 9 Installing the SATA DOM Card Follow these instructions to install a SATA DOM card 1 Locate the SATA DOM Connectors 2 Insert the SATA DOM card into the connector...

Page 52: ...http www tyan com 52 2 1 10 Installing the TPM Card Follow these instructions to install a TPM card 1 Insert the TPM card into the connector 2 Screw the TPM card to the motherboard...

Page 53: ...200 B7108 X4S NVMe SKU only Follow these instructions to install the VROC Key 1 Take out the VROC Key and VROC Kit 2 Connect the VROC Key to the VROC Kit 3 Identify the first pin of the VROC Header Co...

Page 54: ...http www tyan com 54 4 Screw the VROC Key to the node...

Page 55: ...Speed Bridge Board Follow these instructions to remove the M7108 HSBB X4L High Speed Bridge Board 1 Unscrew the High Speed Bridge Board 2 Pull the thumb screw inwards and turn right to lock the thumb...

Page 56: ...the M 2 Card Follow these instructions to install a M 2 card 1 Screw a stand off to the M7108 HSBB X4L 2 Insert the M 2 card 22110 2280 by PCIE interface to the M 2 Connector 3 Push the M 2 card downw...

Page 57: ...to connect the Mini SAS HD Cable 1 Lift up the CPU Air Duct 2 Use a screwdriver to break the semi shearing 3 Use a Mini SAS HD Cable to connect the M7108 HSBB X4L and the RAID card on the Riser Card B...

Page 58: ...LAN Card Follow these instructions to install the OCP LAN Card M7062 B811 1T 1 Use a screwdriver to break the semi shearings of the OCP Mezz slot 2 Insert the M7062 B811 1T OCP LAN Card into the Mezz...

Page 59: ...rack mounting kit Rack mounting kit Rail with Bracket x 2 Screw Sack x 2 2 2 1 Installing the Server in a Rack Follow these instructions to mount the TN200 B7108 into an industry standard 19 rack Not...

Page 60: ...60 2 2 2 Installing the inner Rails to the Chassis 1 Press the latch key to draw out the inner rails from sliding rails 2 Secure inner rails to both sides of the chassis Be sure the mounting holes are...

Page 61: ...http www tyan com 61 3 Use a screwdriver to slightly push open the locking latch and then slide the inner rail backwards to take it off...

Page 62: ...http www tyan com 62 2 2 3 Installing the Outer Rails to the Rack 1 Secure the outer rails to the rack...

Page 63: ...http www tyan com 63 2 2 4 Rack mounting the Server 1 Lift the chassis and then insert the inner slide rails into the outer rails 2 Push the chassis in 3 Screw the chassis to the rack...

Page 64: ...http www tyan com 64 4 Press the latch keys on both sides simultaneously to pull the system out...

Page 65: ...uction This chapter explains how to replace the pre installed components including the S7108 Motherboard M7108T200 L16 1L Riser Card M7108T200 R8 1L Riser Card System Fan and Power Supply etc 3 2 Disa...

Page 66: ...y Follow these instructions to replace the power supply NOTE Remember to untie the power clip first Re connect the power clip after replacement 1 Pull up the lever and press the tab as shown to pull o...

Page 67: ...http www tyan com 67 3 5 Replacing the Fan Follow these instructions to replace the system fan 1 Take out the failed fan 2 Prepare a new fan and insert it into the fan cage...

Page 68: ...eplacing the Riser Card Follow these instructions to replace the M7108T200 L16 1L and M7108T200 R8 1L Riser Cards 1 Unscrew to lift up the Riser Card Brackets 2 Unscrew the M7108T200 L16 1L Riser Card...

Page 69: ...http www tyan com 69 3 Unscrew the M7108T200 R8 1L Riser Card to replace with a new one 4 Follow the steps described earlier in reverse order to reinstall the Riser Card Brackets...

Page 70: ...M7108T200 L16 1L M7108T200 L16 1L Riser Card Specifications Dimension W31 15 x L104 3 x H1 6mm Support 1 PCIE x16 Gen 3 slot M7108T200 R8 1L M7108T200 R8 1L Riser Card Specifications Dimension W30 6...

Page 71: ...ter removing all of the aforementioned cables and components follow these instructions to remove the motherboard from the chassis 1 Unscrew to lift up the Riser Card Brackets HSBB and CPU Air Duct 2 U...

Page 72: ...http www tyan com 72 NOTE...

Page 73: ...st conditions MITAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the mother...

Page 74: ...tp www tyan com 74 4 1 Board Image S7108 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pictu...

Page 75: ...http www tyan com 75 4 2 Block Diagram S7108...

Page 76: ...http www tyan com 76 4 3 Motherboard Mechanical Drawing...

Page 77: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Page 78: ...OM0 FOR SATA DOM J23 6 USB3 0 Connector J4 12 SATA3 0 SATA_DOM1 FOR SATA DOM J30 Jumpers a ME Recovery Mode Jumper J21 d Clear CMOS Jumper J24 b LPC AND eSPI MODE SET Header J5 e SATA AND SATA DOM SET...

Page 79: ...D VCC3_AUX GND PCH_SATA_RAID_KEY J9 TYAN Module Header Signal Pin Pin Signal VCC3 1 2 LFRAME_N ADT0 3 4 KEY ADT1 5 6 RST_N ADT2 7 8 GND ADT3 9 10 CLOCK SERIRQ 11 12 GND PRSNT_N 13 14 V3AUX NC 15 16 EN...

Page 80: ...OM5_TX COM5_RX GND J21 ME Recovery Mode Jumper OPEN Default Pin 1 2 Closed ME force update J22 J29 SATA and SATA DOM Set Jumper Pin 1 2 Closed SATA Default Pin 2 3 Closed SATA DOM J5 LPC and eSPI Mode...

Page 81: ...d to clear the system BIOS setting 1 Power off system and disconnect power connectors from the motherboard 2 Remove the jumper cap from Pin_1 and Pin_2 Default setting 3 Move the jumper cap to close P...

Page 82: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Page 83: ...uds are usually metal and are gold in color Usually the chassis manufacturer will pre install the support studs If you are unsure of stud placement simply lay the motherboard inside the chassis and al...

Page 84: ...the back of the motherboard when installed This will cause malfunction and or damage to your motherboard Some chassis include plastic studs instead of metal Although the plastic studs are usable MITA...

Page 85: ...3DS are supported 1 2V DDR4 DIMMs are supported All installed memory will automatically be detected No jumpers or settings need to be changed for memory detection All memory must be of the same type...

Page 86: ...y Use the same DIMM size Use the same of ranks per DIMM 4 Always install with CPU0 Socket first 4 8 Finishing Up Congratulations on making it this far You have finished setting up the hardware aspect...

Page 87: ...and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program...

Page 88: ...r best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 5 1 4 Setup Variations Not all systems have the same B...

Page 89: ...at can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Memory Information This displays the total memory size System Date Set the Date Use Tab to...

Page 90: ...Configure the iSCSI parameters Intel Virtual RAID on CPU This formset allows the user to manage Intel Virtual RAID on CPU Trusted Computing Trusted Computing Settings ACPI Settings System ACPI Paramet...

Page 91: ...nfiguration Enable Disable Option ROM execution settings etc USB Configuration USB Configuration Parameters Onboard Device Configuration Onboard Device Configuration Option ROM Dispatch Policy Option...

Page 92: ...function Step 1 Select Advanced CSM Configuration Network UEFI Step 2 Select Advanced Network Stack Configuration Network Stack Enabled Step 3 Save changes and reboot iSCSI Initiator Name The worldwid...

Page 93: ...http www tyan com 93 5 3 1 1 Add an Attempt Read only NOTE Only LAN1 supports iSCSI function...

Page 94: ...ssigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to connect iSCSI target via IPv4 stack if failed then attempt IPv6 stack IP4 IP6 Autoconfigure Connection Retry Count The minimum va...

Page 95: ...ask Enter IP address in dotted decimal notation Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Only iqn format is accepted iqu xxx Target IP Ad...

Page 96: ...1 2 Delete Attempts Attempt 1 MAC 34 12 78 56 00 00 PFA Bus 1 Dev 0 Func 0 iSCSI mode Disabled IP version IP4 Disabled Enabled Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit...

Page 97: ...Order Change the order of Attempts using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Attempt 1 Attempt Commit Changes and Exit Commit Ch...

Page 98: ...MD for Volume Management Device on Socket 0 for CPU0 Socket 1 for CPU1 Intel VMD for Volume Management Device for PStack0 Slot 1 4 PStack1 Slot 5 8 PStack2 Slot 9 12 Step 2 Suppose the card is install...

Page 99: ...http www tyan com 99 5 3 2 1 All Intel VMD Controllers Create RAID Volume This page allows you to create a RAID volume Non RAID Physical Disks Read only...

Page 100: ...cial characters and is 16 characters or less Volume0 RAID Level Select RAID Level RAID0 Stripe Enable RAID spanned over VMD Controllers Enter RAID spanned over VMD Controllers blank X Port 0 VMD0 INTE...

Page 101: ...MB Enter desired volume size Maximum size 763099 Create Volume Create a volume with the settings specified above NOTE For Create Volume to be configurable the following items Enable RAID spanned over...

Page 102: ...http www tyan com 102 5 3 2 1 1 1 Create Volume Press y to create n to discard Volume0 RAID0 Stripe 708 0GB Normal Select to see more information about the RAID volume...

Page 103: ...http www tyan com 103 5 3 2 1 1 1 1 Volume0 RAID0 Stripe 708 0GB Normal Read only...

Page 104: ...http www tyan com 104 5 3 2 1 1 1 1 1 Delete Delete the RAID Volume Deleting a volume will reset the disks to non RAID Yes No...

Page 105: ...http www tyan com 105 5 3 2 1 2 Port 0 VMD0 INTEL SSDPE2MD400G4 SN xxxx Port 1 VMD1 INTEL SSDPEDMD400G4 SN xxxx Read only...

Page 106: ...m 106 5 3 3 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available...

Page 107: ...Enable ACPI Auto Configuration Enable or disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enable or disable System ability to Hibernate OS S4 Sleep State This option may not b...

Page 108: ...d Select Dynamic Time system will wake on the current time increase minute s Disabled Fixed Time Dynamic Time When Wake system from S5 is set to Fixed Time Wake up hour Select 0 23 For example enter 3...

Page 109: ...direction enable or disable Disabled Enabled COM1 Serial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Settings The settings specify how the host computer which th...

Page 110: ...erial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with...

Page 111: ...F8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode On this mode enabled only text will be sent This is to capture Terminal data Disable...

Page 112: ...http www tyan com 112 5 3 6 2 Legacy Console Redirection Settings Legacy Serial Redirection Port Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM1...

Page 113: ...er OS through a serial port Read only COM1 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection...

Page 114: ...g data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires...

Page 115: ...r Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe Devices this opti...

Page 116: ...When Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV PXE boot option will not be created Disabled Enabled Ipv4 HTTP Support Enable Ipv4 HTTP Boot Support...

Page 117: ...nable Ipv6 HTTP Boot Support If disabled IPV6 HTTP boot option will not be created Disabled Enabled PXE boot wait time Wait time to press ESC key to abort the PXE boot 0 Media detect count Number of t...

Page 118: ...ed Option ROM Messages Set display mode for Option ROM Force BIOS Keep Current Network Controls the execution of UEFI and Legacy PXE OpROM Legacy UEFI Storage Controls the execution of UEFI and Legacy...

Page 119: ...http www tyan com 119 Other PCI Devices Determines OpROM execution policy for devices other than Network Storage or Video Legacy UEFI...

Page 120: ...FI applications Enabled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Sto...

Page 121: ...vice reset time out USB mass storage device Start Unit command time out 10 sec 20 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Hos...

Page 122: ...oard VGA Disabled Enabled ICC Clock Spread Spectrum Turn on off Spread Spectrum Setting for IsCLK Disabled Enabled Chassis Intrusion detect Enabled when a chassis open event is detected the BIOS will...

Page 123: ...om 123 5 3 12 Option ROM Dispatch Policy PCIE_1 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled PCIE_2 Empty Enable or Disable Option ROM execution for selected Slot Di...

Page 124: ...http www tyan com 124 5 3 13 AST2500 Super IO Configuration Super IO Chip Read only...

Page 125: ...Disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5...

Page 126: ...o Fan Control Automatic Fan Control Disabled Fan speed full on Enabled Automatic fan speed control by temperature Disabled Enabled BMC Alert Beep Enable Disable BMC Alert Beep On Off PMBus Support PMB...

Page 127: ...127 5 3 14 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE SDR can not be m...

Page 128: ...http www tyan com 128 5 4 Platform Configuration PCH Configuration Displays and provides option to change the PCH Settings Server ME Configuration Configure Server ME Technology Parameters...

Page 129: ...s Enable Disable Intel IO Controller Hub devices PCI Express Configuration PCI Express Configuration settings PCH SATA Configuration SATA devices and settings USB Configuration USB Configuration Setti...

Page 130: ...http www tyan com 130 5 4 1 1 PCH Devices Restore AC Power Loss Select AC Power state when power is reapplied after a power failure Power On Power Off Last State...

Page 131: ...http www tyan com 131 5 4 1 2 PCI Express Configuration PCI Express Root Port 1 20 PCI Express Root Port 1 20 Settings...

Page 132: ...ess Root Port Enabled Disabled PCIE ASPM PCI Express Root port ASPM Setting Disable ASPM ASPM L1 ASPM Auto L1 Substates PCI Express L1 Substates settings Disabled L1 1 L1 2 L1 1 L1 2 PCIe Speed Config...

Page 133: ...A Controller Enabled Disabled Configure SATA as Determines how SATA controller s operate AHCI RAID Port 0 Enable or Disable SATA Port Disabled Enabled Hot Plug Designates this port as Hot Pluggable Di...

Page 134: ...in Up will be performed and only the drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled SATA Device Type Identify the SATA port is connect...

Page 135: ...135 5 4 1 4 USB Configuration XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect...

Page 136: ...abled ADR GPIO Select between GPIO_B or GPIO_C GPIO B GPIO C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Enabled Disabled Enable Disable ADR Timer Held off for DEBUG P...

Page 137: ...http www tyan com 137 ADR timer multiplier Select proper ADR timer multiplier x1 8 24 40 56 64 72 80 88 96 x1 x8 x24 x40 x56 x64 x72 x80 x88 x96...

Page 138: ...http www tyan com 138 5 4 2 Miscellaneous Configuration Active Video Select active video type Onboard Device Offboard Device...

Page 139: ...http www tyan com 139 5 4 3 Server ME Configuration Read only...

Page 140: ...option to change the Common RefCode Settings UPI Configuration Displays and provides option to change the UPI Settings Memory Configuration Displays and provides option to change the Memory Settings...

Page 141: ...cal Processor threads Disabled Enabled Max CPUID Value Limit This should be enabled in order to boot legacy OSes that cannot support CPUs with extended CPUID functions Disabled Enabled Execute Disable...

Page 142: ...ardware Prefetcher MLC Streamer Prefetcher MSR 1A4h Bit 0 Enabled Disabled Adjacent Cache Prefetch MLC Spatial Prefetcher MSR 1A4h Bit 1 Enabled Disabled Extended APCI Enable Disable extended APIC sup...

Page 143: ...12M 1G 2G MMIO High Base Select MMIO High Base 56T 40T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up to 32xgranu...

Page 144: ...http www tyan com 144 Numa Enable or Disable Non uniform Memory Access NUMA Disabled Enabled...

Page 145: ...http www tyan com 145 5 5 3 UPI Configuration UPI General Configuration Displays and provides option to change the UPI General Settings...

Page 146: ...ast Link Frequency Select Allows for selecting the UPI Link Frequency 9 6GB s 10 4GB s Auto Use Per Link Setting Link L0p Enable Enable Set the c_l0p_en Disable Reset it Auto Auto decides based on Si...

Page 147: ...http www tyan com 147 5 5 3 1 UPI Status Read only...

Page 148: ...bles this feature Auto Sets it to the MRC default setting current default is Enable Auto POR Disable Memory Frequency Maximum Memory Frequency Selections in Mhz Do not select Reserved Auto 1866 2133 2...

Page 149: ...http www tyan com 149 5 5 4 1 Memory Topology Read only...

Page 150: ...ror on entire memory for TAD0 Enabled Disabled Enable Partial Mirror Partial mirror mode will enable the required size of memory to be mirrored If rank sparing is enabled partial mirroring will not ta...

Page 151: ...http www tyan com 151 SDDC Plus One Enable Disable SDDC Plus One Disabled Enabled Patrol Scrub Enable Disable Patrol Scrub Disabled Enabled...

Page 152: ...D for Volume Management Device Configuration menu PCIe Hot Plug Enable Disable PCIe Hot Plug globally Disabled Enabled Auto Manual PCIe ACPI Hot Plug Enable Disable PCIe ACPI Hot Plug globally or allo...

Page 153: ...x8 x16 IOU2 IIO PCIe Br3 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 x8x8 x16 Socket 0 PcieBr1D00F0 Port 1A Settings related to PCI Express Ports 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D Soc...

Page 154: ...http www tyan com 154 Socket 0 PcieBr3D00F0 Port 3A Settings related to PCI Express Ports 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D...

Page 155: ...used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable This...

Page 156: ...uto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state Disabled...

Page 157: ...IIO PCIe Br3 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 Socket 1 PcieBr1D00F0 Port 1A 1B 1C 1D Settings related to PCI Express Ports 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D Socket 1 PcieB...

Page 158: ...Disable is used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug C...

Page 159: ...uto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state Disabled...

Page 160: ...5 5 3 Intel VT for Directed I O VT d Intel VT for Directed I O VT d Enable Disable Intel Virtualization Technology for Directed I O VT d by reporting the I O device assignment to VMM through DMAR ACPI...

Page 161: ...http www tyan com 161 5 5 5 4 Intel VMD Technology...

Page 162: ...l Volume Management Device Technology in this Stack Disabled Enabled Intel VMD for Volume Management Device for PStack1 Enable Disable Intel Volume Management Device Technology in this Stack Disabled...

Page 163: ...l Volume Management Device Technology in this Stack Disabled Enabled Intel VMD for Volume Management Device for PStack1 Enable Disable Intel Volume Management Device Technology in this Stack Disabled...

Page 164: ...nagement Configuration CPU P State Control P State Control Configuration Sub Menu include Turbo XE and ete Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting Pa...

Page 165: ...state that the BIOS will set before OS hand off Max Performance Max Efficient Set by Intel Node Manager Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Enabled Disabled Turbo Mode E...

Page 166: ...http www tyan com 166 CPU Core Flex Ratio Non Turbo Mode Processor Core Ratio Multiplier Not available if CPU Flex Ratio Override is set to Disabled 23...

Page 167: ...Disable Hardware chooses a P state based on OS Request Legacy P States Native Mode Hardware chooses a P state based on OS guidance Out of Band Mode Hardware autonomously chooses a P state no OS guidan...

Page 168: ...rol CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Disabled Enabled Auto Enhanced Halt State C1E Core C1E auto promotion Control Takes effect after reboot Disabled Enabled OS ACPI Cx Report...

Page 169: ...http www tyan com 169 3 5 5 5 4 Package C State Control Package C State Package C State limit C0 C1 state C2 state C6 non Retention state C6 Retention state No Limit Auto...

Page 170: ...d 3 minutes 4 minutes 5 minutes 6 minutes FRB 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing Reset Power Down Pow...

Page 171: ...minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog timer is disabled Do Nothing Reset Power Down Power Cycle BM...

Page 172: ...nts is set to Disabled the following items are read only Erase SEL Choose options for erasing SEL No Yes on next reset Yes on every reset When SEL is Full Choose options for reactions to a full SEL Do...

Page 173: ...parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port...

Page 174: ...e Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window will...

Page 175: ...activated when Platform Key PK is enrolled System mode is User Deployed and CSM function is disabled Disabled Enabled Secure Boot Mode Secure Boot mode selector Standard Custom In Custom mode Secure...

Page 176: ...ss Yes to install factory default keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 has of the binary into Authorized signature Database db Save All Secure Boot Variables...

Page 177: ...Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 bin 2...

Page 178: ...256 Key source Default External Mixed Test Set New Append OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X50...

Page 179: ...setup activation key 65535 0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Boot Option...

Page 180: ...Policy Controls the placement of newly detected UEFI boot options Default Place First Place Last Wait for ESC If Error Wait for ESC key to be pressed if error occurs Disabled Enabled Endless Boot Ena...

Page 181: ...http www tyan com 181 5 8 1 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to delete UEFI Built in EFI Shell...

Page 182: ...it Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Sa...

Page 183: ...Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup opt...

Page 184: ...http www tyan com 184 NOTE...

Page 185: ...6 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Page 186: ...on up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Sta...

Page 187: ...tialization North Bridge module specific 0x17 Pre memory North Bridge initialization North Bridge module specific 0x18 Pre Memory North Bridge initialization North Bridge module specific 0x19 Pre memo...

Page 188: ...Memory South Bridge initialization South Bridge module specific 0x3D Post Memory South Bridge initialization South Bridge module specific 0x3E Post Memory South Bridge initialization South Bridge modu...

Page 189: ...gered by firmware Auto recovery 0xF1 Recovery condition triggered by user Forced recovery 0xF2 Recovery process started 0xF3 Recovery firmware image is found 0xF4 Recovery firmware image is loaded 0xF...

Page 190: ...odule specific 0x6C North Bridge DXE initialization North Bridge module specific 0x6D North Bridge DXE initialization North Bridge module specific 0x6E North Bridge DXE initialization North Bridge mod...

Page 191: ...vices connect 0x99 Super IO initialization 0x9A USB initialization is started 0x9B USB Reset 0x9C USB Detect 0x9D USB Enable 0x9E 0x9F Reserved for future AMI codes 0xA0 IDE initialization is started...

Page 192: ...outh Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Outp...

Page 193: ...is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 System is waking up from the S2 sleep st...

Page 194: ...http www tyan com 194 NOTE...

Page 195: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Page 196: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion i...

Page 197: ...P E24 J9 Ctrl cable J33 PW1 2x4P PWR cable 1 J34 PW2 2x4P PWR cable 2 J35 3 Ctrl 2x4P PWR Cable For B7108T200X4 220PV3HR M7108 FB to M7108 HDBP U12 M7108 FB Connect to M7108 HDBP U12 J9 Ctrl cable J33...

Page 198: ...108 HDBP U12 J7 FP ctrl cable 1 front left J32 Node0 J8 FP ctrl cable 2 front left J30 Node1 J7 FP ctrl cable 3 front right J31 Node2 J8 FP ctrl cable 3 front right J29 Node3 6 PDB Ctrl Cable M7108 FB...

Page 199: ...rd A table of BIOS Temp sensor name explanation is also included for readers reference Figure 1 Sensor Location NOTE The red spot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is l...

Page 200: ...http www tyan com 200 BIOS Temp Sensor Name Explanation...

Page 201: ...CH MB_Air_Inet Temperature of the M B Air Inlet Area MB_Air_Outlet Temperature of the M B Air Outlet Area P0_MOSFET The Max Temperature of CPU0 MOSFET P1_MOSFET The Max Temperature of CPU1 MOSFET P0_D...

Page 202: ...Temperature of P1_MC0_ DIM_ C Slot P1_MC1_DIM_CH_D The Max Temperature of P1_MC1_ DIM_ D Slot P1_MC1_DIM_CH_E The Max Temperature of P1_MC1_ DIM_ E Slot P1_MC1_DIM_CH_F The Max Temperature of P1_MC1_...

Page 203: ...U Heatsink FRU TH 0240 343T56900005 1U Heatsink FRU TH 0250 343T56900006 1U Heatsink Compatible Accessories FRU RC 0820 411T56900040 Riser Card M7108T200 R8 1L 1U Riser Card w PCI E x8 slot HH HL FRU...

Page 204: ...upports 6 2 5 SSD HDDs that only for TN200 B7108 X4S FRU SO 9220 5412T5690009 3 5 Node Kit for X4L SKU 1U Computing Node Supports 3 3 5 HDD Bays that only for TN200 B7108 X4L HDD Holder FRU SM 0091 34...

Page 205: ...expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports...

Page 206: ...oper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...

Reviews: