3.3.4   Trusted Computing  

 

 
Security Device Support 

Enable or disable BIOS support for security device. O.S. will not show Security 
device. O.S. will not show Security Device. TCG EFI protocol and INT1A interface 
will not be available. 

Enabled 

/ Disabled

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for S8026

Page 1: ...rosoft Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for acc...

Page 2: ...face Material 30 2 8 Tips on Installing Motherboard in Chassis 31 2 9 Installing the Memory 33 2 10 Attaching Drive Cables 37 2 11 Installing Add In Cards 38 2 12 Connecting External Devices 39 2 13 I...

Page 3: ...SATA Single Cable x 2 Rear IO shielding x 3 1 x S8026 Quick Installation Guide 1 x TYAN Driver CD M 2 Screw kit x2 IMPORTANT NOTE Sales samples may not come with any of the accessories listed above If...

Page 4: ...ing requirements for today s IT environments Remember to visit the TYAN website at http www tyan com There you can find all the information on all TYAN products as well as all the supporting documenta...

Page 5: ...1 DB 9 COM Connector at rear COM1 1 Header COM2 VGA 1 D Sub 15 pin VGA port at rear RJ 45 2 GbE ports 1 Dedicated for IPMI Front Panel 1 2x12 pin SSI front panel header Power SSI 24 pin 8 pin 8 pin po...

Page 6: ...ctor EATX Board Dimension 12 x13 305x330mm Operating System OS supported list Please refer to our AVL support lists Regulation FCC DoC Class A CE DoC Class A Operating Environment Operating Temp 10 C...

Page 7: ...ical support for details Recommended TYAN Riser Card M7106 L24 3F PCI E x16 slot 2U riser card left M7106 L24 3F PCI E x16 slot 2U riser card right Others 1 PCI E Gen3 x16 OCP 2 0 slots conn A conn B...

Page 8: ...nt controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature 24 bit high quality video compression 10 100 1000 Mb s MAC interface BIOS Brand ROM size A...

Page 9: ...Installation Guide Installation CD 1 TYAN Device Driver CD 1 3 Software Specifications For the latest AST2500 User s Guide and OS operation system support please visit the Tyan s Web site at http www...

Page 10: ...onditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboar...

Page 11: ...www tyan com 11 2 1 Board Image S8026GM2NR This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pic...

Page 12: ...http www tyan com 12 2 2 Block Diagram S8026 Block Diagram...

Page 13: ...http www tyan com 13 2 3 Motherboard Mechanical Drawing...

Page 14: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Page 15: ...SB Connector TYPEA_USB1 32 Reset Button COLD_RST_BTN1 15 NGFF 22x80mm Connector NGFF1 33 Power Button PWR_BTN1 16 SATADOM Connector SATA3 0 signals 7Pin _2Power SATADOM2 34 NMI Button NMI_BTN 17 SATAD...

Page 16: ...G_RX_P4 GND 7 P1 VCC5 VCC5 P2 TYPEA_USB1 Vertical Type_A USB3 0 Connector Signal Pin Pin Signal 5V 1 2 USB2 0_DATA_N USB2 0_DATA_P 3 4 GND USB3 0_RX_N 5 6 USB3 0_RX_P GND 7 8 USB3 0_TX_N USB3 0_TX_P 9...

Page 17: ...al Pin Pin Signal P3V3 1 2 FRAME_N LAD0 3 4 KEY LAD1 5 6 PLT_RST_N LAD2 7 8 GND LAD3 9 10 CLK_33M DBG_SERIRQ 11 12 GND DBG_PRES_N 13 14 VCC3_AUX TPM_ADDR_MB 15 16 PCH_TPM_PP_EN COM2 COM2 Header Signal...

Page 18: ...ED_SW 19 20 INTRUSION NC 21 22 LAN2LED NMI_SW 23 24 LAN1_LED_N IPMB_HD1 IPMB Connector Signal Pin Pin Signal BMC_SMB_DATA 1 2 GND BMC_SMB_CLK 3 4 NC PSMI_HD1 PSMI Connector Pin 1 2 3 4 5 Signal SMB_CL...

Page 19: ...3 Default setting 3 Move the jumper cap to close Pin_1 and Pin_2 for several seconds to Clear CMOS 4 Put jumper cap back to Pin_2 and Pin_3 Default setting 5 Reconnect power connectors to the motherbo...

Page 20: ...11 OCP CONN MUX PRSENT select Jumper Signal Pin Pin Signal VDD_33_RUN 1 2 OCP_PRSNB1_L GND 3 1 2 OCP CONN_B NOT PRESENT MUX TO PESLOT1 Default 2 3 OCP CONN_B PRESENT MUX TO OCP CONN_B System Reset Jum...

Page 21: ...ttp www tyan com 21 J2 NVMe or SATA select Jumper J9_2 4 Signal Pin Pin Signal VDD_33_RUN 1 2 VDD_33_RUN J1_SATA_NVME 3 4 J1_SATA_NVME GND 5 6 GND 2 4 NVME or SATA set up by BIOS 4 6 SATA Set up by HW...

Page 22: ...TXP SATA2_RXN A15 B15 SATA2_TXN GND6 A16 B16 GND20 SATA3_RXP A17 B17 SATA3_TXP SATA3_RXN A18 B18 SATA3_TXN GND7 A19 B19 GND21 A20 A20 B20 B20 A21 A21 B21 B21 GND8 A22 B22 GND22 SATA4_RXP A23 B23 SATA4...

Page 23: ...is enabled ON RED indicates that the error detection circuitry has detected errors in the configuration CRAM bits LED2 FPGA_NSTA TUS LED Pin Signal VDD_33_DUAL N17323125 State Description OFF OFF The...

Page 24: ..._M2 NGFF2_LE D Pin Signal VDD_33_RUN NGFF2_LED_L State Description OFF OFF The LED shuts off when no NGFF2 SSD insert ON Green The LED lights up when detect the NGFF2 SSD HDD_LED3 HDD_ACT_ LED Pin Sig...

Page 25: ...ow to install the processors and heat sinks Please note that the illustrations are based on socket which may not look exactly like the motherboard you purchased Therefore the illustrations should be h...

Page 26: ...the rail frame Note During installation observe the following make sure to push the carrier frame with package towards the end of the rail frame until it clicks in place do not drop the carrier frame...

Page 27: ...e rail frame with the installed package Then push both edges of the rail frame firmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure th...

Page 28: ...nds enter thermal protection and shut down if heatsinks are not installed Caution Take caution of the air flow must be in the direction which paralleled with memories For the safest method of installa...

Page 29: ...http www tyan com 29 3 Connect the heatsink power cable to the mainboard connector...

Page 30: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Page 31: ...simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard w...

Page 32: ...ad of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Page 33: ...with the motherboard and processor Check the TYAN Web site at http www tyan com for details of the type of memory recommended for your motherboard Support 16 DDR4 288 pin DIMM slots Support 8 memory c...

Page 34: ...D2_Umc1_CH_G0 P0_D2_Umc1_CH_G1 P0_D2_Umc0_CH_H0 P0_D2_Umc0_CH_H1 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each chann...

Page 35: ...http www tyan com 35 AMD SP3 SP4 Families Support...

Page 36: ...ock a DIMM socket by Press the retaining clip outwardly in the following illustration 2 Align the memory module with the socket such that the DIMM NOTCH match the KEY SLOT on the socket 3 Seat the mod...

Page 37: ...owing illustrates how to make a SATA Cable connection If you are in need of SATA SAS cables or power adapters please contact your local sales representative 1 SATA drive cable connection 2 SATA drive...

Page 38: ...rt the card firmly Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and th...

Page 39: ...om 5720 chipset Onboard LAN LED Color Definition The Three 3 onboard Ethernet ports have green and Amber LEDs to indicate LAN status The chart below illustrates the different LED states 1Gbps LAN Link...

Page 40: ...12VA1 GND 3 4 12VA1 GND 5 6 12VA2 GND 7 8 12VA2 2 14 Finishing Up Congratulations on making it this far You have finished setting up the hardware aspect of your computer Before closing up your chassis...

Page 41: ...to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are...

Page 42: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Page 43: ...that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Product Name It displays Product information BIOS Version It displays BIOS version info...

Page 44: ...Date Set the Date Use Tab to switch between Date elements Default Ranges Year 2005 2099 Months 1 12 Days dependent on month System Time Adjust the system clock HH 24 hours format MM Minutes SS Second...

Page 45: ...Configuration CPU Configuration parameters Onboard Device Configuration Onboard Device and Function Configuration PCIE Slot Configuraion Onboard PCIE Slot Configuration Trusted Computing Trusted Comp...

Page 46: ...on SIO Configuration PCI Subsystem Settings PCI PCI X and PCI Express Settings CSM Configuration CSM Configuration Enable Disable Option ROM execution setting etc NVMe Configuration NVMe Device Option...

Page 47: ...tyan com 47 3 3 1 CPU Configuration SVM Mode Enable disable CPU virtulization Disabled Enabled SMEE Control secure memory encryption enable Disabled Enabled CPU 0 Information View Information related...

Page 48: ...http www tyan com 48 3 3 1 1 CPU0 Information...

Page 49: ...d Active Video Select between onboard or external VGA support Onboard Offboard Onboard LAN B5720 Enable Disable Onboard LAN Device Disabled Enabled LAN1 Port1 OPROM Enable Disable Load Option ROM For...

Page 50: ...MI Button Enable or disable NMI button Disabled Enabled Clock Spread Spectrum Enable Disable CG1_PLL Spread Spectrum Disabled Enabled Serial IRQ Mode Configure Serial IRQ Mode Quiet Continuous 3 3 3 P...

Page 51: ...th Configuration Auto is detected by GPIO x8x8 x16 x4x4x4x4 x8x8 x16 Auto Riser L Down Slot Link Width Configution Setting Pcie Slot Link Width x4x4 x8 Riser R Middle Slot Link Width Configuration Rig...

Page 52: ...k Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Riser L Middle Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Riser L Down Slot...

Page 53: ...ed Computing Security Device Support Enable or disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will no...

Page 54: ...www tyan com 54 3 3 5 Hardware Health Configuration Auto Fan Control Auto Fan Control help Disabled Enabled BMC Alert Beep Enable Disable BMC Alert Beep On Off PMBus support PMBus Support Disabled Ena...

Page 55: ...55 3 3 5 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Page 56: ...http www tyan com 56...

Page 57: ...tings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select dynamic time system will wake on the current time increase...

Page 58: ...ial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the...

Page 59: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with t...

Page 60: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 61: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with t...

Page 62: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 63: ...esolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST when Bootloader is selected then Legacy Console Redirection is disabled before booting to le...

Page 64: ...r OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setti...

Page 65: ...n sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses tw...

Page 66: ...e Serial Port 1 View and Set Basis properties of the SIO Logical device Like IO Base IRQ Range DMA Channel and Device Mode Active Serial Port 2 View and Set Basis properties of the SIO Logical device...

Page 67: ...abled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5...

Page 68: ...abled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5...

Page 69: ...ices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this option Enable or Disable Single...

Page 70: ...http www tyan com 70 3 3 9 1 PCI Express Subsystem Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes...

Page 71: ...twork Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Video Controls the execution o...

Page 72: ...http www tyan com 72 3 3 11 NVMe Configuration...

Page 73: ...http www tyan com 73 3 3 12 SATA Configuration...

Page 74: ...bled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support...

Page 75: ...vice reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Hos...

Page 76: ...w tyan com 76 3 4 Chipset Menu SMT Mode simultaneous multithreading OFF 1T single thread Auto 2T two thread if capable off Auto North Bridge North Bridge Parameters Error Management Error Management s...

Page 77: ...http www tyan com 77 3 4 1 North Bridge Configuration Memory Configuration Memory Configuration Socket 0 Configuration View Information related to Socket 0...

Page 78: ...http www tyan com 78 3 4 1 1 Memory Configuration Memory Clock This option Allows User to select different memory Clock Default value is 2400 MT s Auto 1333MHz 1600MHz 1866MHz 2133MHz 2400MHz 2667MHz...

Page 79: ...http www tyan com 79 3 4 1 2 Socket 0 Information...

Page 80: ...ble PFEH cloak individual banks and mask deferred error interrupts from each bank Disabled Enabled NOTE The item Platform First Error Handling must be set up to Enabled the following item will appear...

Page 81: ...http www tyan com 81 3 5 AMD CBS Menu...

Page 82: ...ubmenu Core Performance Boost Allows Core Performance Boost CPB to be forced to disabled Disabled Auto Global C state Control Controls IO based C state generation and DF C states Disabled Enabled Auto...

Page 83: ...http www tyan com 83 3 5 1 1 Core Thread Enablement Submenu...

Page 84: ...bmenu Downcore control Sets the number of cores to be used Once this option has been used to remove any cores a POWER CYCLE is required in order for future selections to take effect TWD 1 1 TWD 2 0 TH...

Page 85: ...erleaving Controls fabric level memory interleaving AUTO none channel die socket Note that channel die and socket has requirements on memory populations and it will be ignored if the memory doesn t su...

Page 86: ...http www tyan com 86 3 5 3 UMC Common Options Submenu...

Page 87: ...http www tyan com 87 3 5 3 1 DDR4 Common Options Submenu...

Page 88: ...www tyan com 88 3 5 3 1 1 Common RAS Options Submenu Data Poisoning Enable disable data poisoning UMC_CH EccCtrl UcFatalEn UMC_CH EccCtrl WrEccEn Should be enabled disabled together Disabled Enabled...

Page 89: ...1 1 ECC Configuration Submenu DRAM ECC Symbol Size DRAM ECC Symbol Size x4 x8 UMC_CH EccCtrl EccSymbolSize X4 x8 Auto DRAM ECC Enable Use this option to enable disable DRAM ECC Auto will set ECC to e...

Page 90: ...http www tyan com 90 3 5 3 2 Security Submenu Data Scramble Data scrambling DataScrambleEn Enabled Disabled Auto...

Page 91: ...Submenu Chipselect Interleaving Interleave memory blocks across the DRAM chip selects for node 0 Disabled Auto BankGroupSwap This is an advanced performance setting specifies if the system should use...

Page 92: ...terminism settings power performance Auto Power Perfomance cTDP Control Auto Use the fused cTDP Manual User can set customized cTDP Manual Auto ACS Enable Supported functions of Access Control Service...

Page 93: ...http www tyan com 93 3 5 4 1 NB Configuration Submenu IOMMU Enable Disable IOMMU Disabled Enabled Auto...

Page 94: ...http www tyan com 94 3 5 4 FCH Common Options Submenu...

Page 95: ...http www tyan com 95 3 5 4 1 Ac Power Loss Options Submenu Restore Ac Power Loss Select Ac Loss Control Method Power Off Power On Last State...

Page 96: ...er Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FBR 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing Re...

Page 97: ...sabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled...

Page 98: ...boot Enabled Disabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Log EFI S...

Page 99: ...http www tyan com 99 3 6 2 BMC Network Configuration Submenu...

Page 100: ...y BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Configure IPV4 support Management Port 2 Enable Disable BMC Share NIC Disabled Enabled Configure IPV6 sup...

Page 101: ...trator Password Set Administrator Password User Password Set User Password Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function Disabled Enabled Sec...

Page 102: ...rolled System mode is User Deployed and CSM function is disabled Enabled Disabled Secure Boot Mode Secure Boot mode selector Custom mode enables users to change Image execution policy and manage secur...

Page 103: ...o User Mode install all Factory Default keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Autorized Signature Database db Platform Key PK Enroll Fa...

Page 104: ...ertificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mix...

Page 105: ...t External Mixed Test OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin...

Page 106: ...0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enabled or Disabled Endless...

Page 107: ...http www tyan com 107 Boot Option Priorities Boot Option 1 Sets the system boot order Device Name Disabled Delete Boot Option Remove an EFI boot option from the boot order...

Page 108: ...http www tyan com 108 3 8 1 Delete Boot Option Configuration Delete Boot Option Sets the system boot order Device Name Select one to Delete...

Page 109: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Page 110: ...http www tyan com 110 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Device Name...

Page 111: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Page 112: ...0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used P...

Page 113: ...tion North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initializ...

Page 114: ...odule specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE PIL is started PCI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory init...

Page 115: ...oaded 0xF5 0xF7 Reserved for future AMI progress codes Recovery Error Codes 0xF8 Recovery PPI is not available 0xF9 Recovery capsule is not found 0xFA Invalid recovery capsule 0xFB 0xFF Reserved for f...

Page 116: ...lization is started 0x71 South Bridge DXE SMM initialization is started 0x72 South Bridge devices initialization 0x73 South Bridge DXE initialization South Bridge module specific 0x74 South Bridge DXE...

Page 117: ...s Codes section below 0xAD Ready To Boot event 0xAE Legacy Boot event 0xAF Exit Boot Services event 0xB0 Runtime Set Virtual Address MAP Begin 0xB1 Runtime Set Virtual Address MAP End 0xB2 Legacy Opti...

Page 118: ...Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1...

Page 119: ...explanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the...

Page 120: ...http www tyan com 120 BIOS Temp Sensor Name Explanation...

Page 121: ...lot P0_D0_UMC0_CH_D The highest temperature of CPU0 D0 UMC0 channel D slot P0_D3_UMC0_CH_E The highest temperature of CPU0 D3 UMC0 channel E slot P0_D3_UMC1_CH_F The highest temperature of CPU0 D3 UMC...

Page 122: ...http www tyan com 122 NOTE...

Page 123: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Page 124: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Page 125: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Page 126: ...aster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data trans...

Page 127: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronou...

Page 128: ...oard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC...

Page 129: ...omprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system compon...

Page 130: ...ed by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Reviews: