background image

 

http://www.tyan.com

 

12

 

 

Summary of Contents for GN70-B8236-HE

Page 1: ...1 http www tyan com GN70 B8236 HE Service Engineer s Manual...

Page 2: ...2 http www tyan com...

Page 3: ...bility or warranties relating to fitness for a particular purpose or merchantability MiTAC retains the right to make changes to produce descriptions and or specifications at any time without notice In...

Page 4: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in...

Page 5: ...an introduction to the TYAN GN70 B8236 HE barebones standard parts list describes the external components gives a table of key components and provides block diagram of the system Chapter2 Covers proc...

Page 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where i...

Page 7: ...mbols on Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Warning This symbo...

Page 8: ...nees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rac...

Page 9: ...install the Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails P...

Page 10: ...y to temperatures higher than 60 C 140 F The system battery is not replaceable If the battery is replaced by an incorrect type there is danger of explosion Replace the battery only with a spare design...

Page 11: ...ts Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service di...

Page 12: ...http www tyan com 12...

Page 13: ...8 1 5 4 Jumpers Connectors 29 1 5 5 System Block Diagram S8236 30 1 5 6 Internal View 31 Chapter 2 Setting Up 33 2 0 1 Before you Begin 33 2 0 2 Work Area 33 2 0 3 Tools 33 2 0 4 Precautions 34 2 1 In...

Page 14: ...the Motherboard 61 3 5 Replacing the Power Distribution Board 62 3 6 Replacing the Front Panel Board 63 3 6 1 Front Panel Board Specifications 65 3 6 2 FPB LED and Connector Pin Definition 66 3 7 Rep...

Page 15: ...le 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementtation The GN70 B8236 HE not only empowers your company in nowadays IT demand but also offers a smooth pat...

Page 16: ...Ds 1 PWR 1 ID 1 Warning 3 LAN Front Panel I O Ports 2 USB ports Type Q ty 2 5 or 3 5 Hot Swap 8 External Drive Bay Supported HDD Interface SATA II 3 0Gb s SAS 6 0Gb s System Cooling Configuration FAN...

Page 17: ...64GB UDIMM Memory channel 4 Channels per CPU Memory Memory voltage 1 5V or 1 35V PCI E 3 PCI E Gen 2 x16 slots Pre install TYAN Riser Card 1 M2201 L16 2F PCI E x16 2U riser card left 2 M2202 R16 2F PC...

Page 18: ...compliant baseboard management controller BMC Supports storage over IP and remote platform flash BIOS update Server Management AST2050 iKVM Feature 24 bit high quality video compression Dual 10 100 Mb...

Page 19: ...Barebone Manual 1 MB User s manual 1 BB User s manual Installation CD 1 TYAN installation CD Heatsink Cooler 2 G34 CPU heatsinks Rail kit 1 CRAL 0031 sliding rail kit for KGT24 KGT62 Mounting Ear 1 m...

Page 20: ...should arrive packaged as illustrated below 1 4 1 Box Contents Component Description 2U chassis 8 hot swap HDD bays TYAN S8236 system board pre installed 1 1 ERP1U hot swap 770W RPSU or 1 1 ERP1U hot...

Page 21: ...http www tyan com 21 M2202 R8 2F riser card pre installed...

Page 22: ...or browse to TYAN s website for service http www tyan com The web site also provides information of other TYAN products as well as FAQs compatibility lists BIOS settings etc TYAN Motherboard Drive CD...

Page 23: ...http www tyan com 23 SGCC Bracket_L SGCC Bracket_R AC Power Cord 125V US AC Power Cord 250V Europe Barebone Manual Mainboard Manual Addendum for China Use Only...

Page 24: ...oduct The following views show you the product 1 5 1 System Front View 1 Ears 2 3 5 HDD bays 3 USB Ports 4 ID Button 5 NMI Button 6 RESET Button 7 NIC1 NIC2 NIC3 8 ID LED 9 Warning LED 10 BMC LED rese...

Page 25: ...ff Blinking Green LAN active On Green LAN linked NIC1 off off LAN not linked Blinking Green LAN active On Green LAN linked NIC2 off off LAN not linked Blinking Green LAN active On Green LAN linked NIC...

Page 26: ...D Color Amber Activity LED Color Green No Driver Present or power disconnected OFF OFF No Activity OFF ON Driver Present Access Activity OFF Blinking HDD Fail On Solid OFF Identify Locate the HDD Blin...

Page 27: ...n Green 10Mb 100Mb 1000Mb linked Blinking Green 10Mb 100Mb 1000Mb activity RJ 45 Activity left Disabled Flash Green No LAN linked On Amber 1000Mb linked On Green 100Mb linked RJ 45 Linkage Right Disab...

Page 28: ...ww tyan com 28 1 5 3 Motherboard S8236 Layout The diagram is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above d...

Page 29: ...J32 LAN3 Active LED Header J53 HDD Fault Header J59 IPMB Header JP1 JP2 COM2 Function Select Jumper JP3 Clear CMOS Jumper JP6 Front Panel ID LED Button JP7 Chassis Intrusion Header LED1 ID LED LED2 SA...

Page 30: ...http www tyan com 30 1 5 5 System Block Diagram S8236...

Page 31: ...yan com 31 1 5 6 Internal View With Riser Card Brackets 1 3 5 HDD cage underneath 2 SAS SATA HDD Backplane Board 3 System Fan Unit 4 Power Distribution Board 5 PCI E Riser Card Bracket 6 Power Supply...

Page 32: ...http www tyan com 32 Without Riser Card Brackets 1 3 5 HDD cage underneath 2 SAS SATA HDD Backplane Board 3 System Fan Unit 4 Power Distribution Board 5 Power Supply underneath...

Page 33: ...ts separated Putting all small components in separate containers prevents them from becoming lost Adequate lighting and proper tools can prevent you from accidentally damaging the internal components...

Page 34: ...id touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static s...

Page 35: ...nts on to the motherboard including CPUs memory modules HDD and PCI E cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove the GN70 B8236 HE chassis cover 1 Unscrew the rear top...

Page 36: ...http www tyan com 36 3 Slide the rear top cover out...

Page 37: ...com 37 2 1 2 Removing the Riser Card Brackets Follow these instructions to remove the PCI E Riser Card Brackets 1 Loose four thumb screws to release the PCI E Riser Card Brackets 2 Lift up the Riser...

Page 38: ...PU and Heatsink Follow the steps below on installing CPUs and CPU heatsinks 1 Locate the CPU sockets 2 Pull the lever slightly away from the socket and then push it to a fully open position 3 Push the...

Page 39: ...an com 39 4 Take out the protection cap 5 Place the CPU into the socket and make sure that the gold arrow is located in the right direction 6 Close the CPU socket cover and press the lever down to sec...

Page 40: ...http www tyan com 40 7 Position the heatsink on top of the CPU and secure it with 2 screws 8 Repeat the procedures mentioned earlier to install the second CPU and heatsink...

Page 41: ...herboard 2 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 3 Align the memory module with the slot When inserted properly the memory slot loc...

Page 42: ...http www tyan com 42 Memory Population Option Table The following pictures show common types of DDR3 memory modules...

Page 43: ...1_DIMM 12 C1 CPU1_DIMM 13 B0 CPU1_DIMM 14 B1 CPU1_DIMM 15 A0 CPU1_DIMM 16 A1 NOTE 1 indicates a populated DIMM slot 2 Paired memory installation for Max performance 3 Populate the same DIMM type in ea...

Page 44: ...Hz SR and DR n a 1066MHz 1066MHz SR and DR SR and DR 1066MHz 1333MHz SR and DR n a 1066MHz 1333MHz SR and DR SR and DR Notes U DIMM can support up to 4GB sized DIMM s Maximum of 8GB per channel SR and...

Page 45: ...n a 1066MHz QR SR DR and QR n a 1333MHz SR and DR n a n a 1333MHz QR n a Notes RDIMM can support up to 16GB sized DIMM s SR and DR Memory has a MAX amount of 16GB per channel SR and DR 1 35v Memory M...

Page 46: ...pport up to eight 8 3 5 hard drives Follow these instructions to install a hard drive Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack 1 Press the loc...

Page 47: ...http www tyan com 47 3 Remove the 6 screws 4 Place a hard drive into the drive tray 5 Use 6 HDD screws to secure the HDD...

Page 48: ...http www tyan com 48 6 Reinsert the HDD tray into the chassis and press the locking lever to secure the tray...

Page 49: ...supports three PCI E Riser Card Brackets Follow these instructions to install PCI E cards 1 Unscrew the PCI E slots to take out the PCI brackets 2 Insert the PCI E cards and securely screw as shown 3...

Page 50: ...e TYAN GN70 B8236 HE into an industry standard 19 rack NOTE Before mounting the TYAN GN70 B8236 HE in a rack ensure that all internal components have been installed and that the unit has been fully te...

Page 51: ...51 http www tyan com 2 Repeat the same procedures for the front end of the rail Front 3 Push the locking latch to secure the rail to the rack Repeat the same procedures for the other rail Left Right...

Page 52: ...to its full length push the locking tab of the rail upward and then the rail can slide freely There are three holes on each rail which are used to hook and secure the chassis 5 Align the studs on the...

Page 53: ...http www tyan com 53 6 Push the chassis back into the rack 7 The installation is now complete...

Page 54: ...Server from a Rack Follow these instructions to remove the TYAN GN70 B8236 HE from an industry standard 19 rack 1 Push the ears to pull the chassis forward 2 Push forward the locking tabs on both rai...

Page 55: ...3 Follow the steps described earlier in reverse to remove the chassis from the rack NOTE To avoid injury it is strongly recommended that at least two people lift the TYAN GN70 B8236 HE to hook on or u...

Page 56: ...http www tyan com 56 NOTE...

Page 57: ...ter explains how to replace the pre installed components including the S8236 Motherboard M1709G70 FPB Front Panel Board PCI E Riser Card M1245G70 BP6 8 SATA SAS HDD Board System Fan and Power Supply U...

Page 58: ...otherboard Components Follow these instructions to replace motherboard components including the motherboard 3 4 1 Replacing PCI E Riser Card Cards The GN70 B8236 HE has three pre installed PCI E 16 ri...

Page 59: ...http www tyan com 59 3 Repeat the same procedures for the second and third Riser Card Brackets 4 Unscrew the M2202 F16 2F riser card to replace a new one if necessary...

Page 60: ...replacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all cables 1 Disconnect the power and PSMI cables 2 Disconnect the Mini S...

Page 61: ...l of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the heatsinks and processors if installed 2 Remove the nine screws securing the motherb...

Page 62: ...yan com 62 3 5 Replacing the Power Distribution Board Follow these instructions to replace the M1601T70 D PDB power distribution board 1 Disconnect all cables 2 Unscrew to replace a new power distribu...

Page 63: ...these instructions to replace the M1709G70 FPB Front Panel Board 1 Unscrew to release the Front Panel Board Module 2 Push the Front Panel Board Module forward 3 Disconnect the Front Panel Control and...

Page 64: ...http www tyan com 64 5 Follow the steps described earlier in reverse to reinstall the Front Panel Board...

Page 65: ...Connectors One 2x15 pin header for front panel connector of motherboard and HDD backplane board LEDs Power On Off LED Color Green after power on ID LED Color Blue Warning IPMI LED Dual Color Yellow W...

Page 66: ...on the server by clicking the Chassis Locate LED key ID LED Off Off System not identified For more information on the Chassis Locate LED please visit our Web site for the latest Pilot II Software Conf...

Page 67: ...http www tyan com 67 USB Connector J1 Definition Pin Pin Definition VCC 1 2 VCC USB1 3 4 USB2 USB1 5 6 USB2 GND 7 8 GND KEY 9 10 GND...

Page 68: ...m 68 3 7 Replacing the System Fan Follow these instructions to replace the system fan 1 Press the latch in the direction as shown to lift up the fan from cage 2 Take out the fan unit 3 Loose the screw...

Page 69: ...n com 69 4 Push the latch in the direction as the arrow shown to release the fan from the iron holder 5 Remove the iron holder to replace a new fan 6 After replacing a new one put the fan unit back in...

Page 70: ...Replacing the Fan Backplane Board Follow these instructions to replace the Fan Backplane Board in your system 1 Press the latch in the direction as shown to lift up the fan from cage 2 Remove all eig...

Page 71: ...http www tyan com 71 3 Disconnect all cables attached to the Fan Backplane Board 4 Use a screw driver to unscrew the Fan Module 5 Disconnect the power and fan cables 6 Lift up the Fan Module...

Page 72: ...http www tyan com 72 7 Release the 14 screws on the Fan Backplane Board to replace a new one 8 Follow the steps described in reverse order to reinstall the fan cage...

Page 73: ...ctor 254 mm x 82 mm 4 layer PCB Integrated I O 2 1x4pin R A Power Connector 8 2x2pin Fan Connectors 1 2 x10pin Barebone Fan Connector 1 2x2pin Connector for S7015 3 8 2 Fan BP Board LED Definitions FA...

Page 74: ...plane Board 1 Refer to Section 3 8 Replacing the Fan Backplane Board for how to remove the Fan Module Disconnect the power cables attached to the HDD BP Board 2 Unscrew the HDD BP Board Remove the HDD...

Page 75: ...ar Form Factor 81 8 x 436 mm 4 layer PCB Integrated I O 8 SAS HDD Connectors 2 Mini SAS Connectors to MB and RAID Card 1 2 x 4 pin Power Connector LEDs 8 HDD active LEDs 8 HDD fault LEDs PW3 Pin defin...

Page 76: ...onnected OFF OFF No Activity OFF ON Driver Present Access Activity OFF Blinking HDD Fail On Solid OFF Identify Locate the HDD Blinking 4Hz x SAS SATA RAID Building Blinking 1Hz x NOTE If the LSI 9280...

Page 77: ...tyan com 77 3 10 Replacing the Power Supply 1 Press and hold the latch to pull the power supply out 2 After replacing a new power supply press and hold the latch to push the power supply back into the...

Page 78: ...http www tyan com 78 NOTE...

Page 79: ...SAS_2 J11 2 FAN Control Cable FAN Board M1806G70 FB Connects to Motherboard J8 J28 3 Front Panel Control Cable Front Panel Board M1709G70 FPB Connects to Motherboard J3 J23 4 USB Cable Front Panel Bo...

Page 80: ...com 80 PATX2 MB2 PW3 J7 PSMI J31 Power Board M1601T70 D PDB Connects to FAN Board M1806G70 FB PW4 FAN BD1 PW2 PW5 FAN BD2 PW1 Power Board M1601T70 D PDB Connects to SAS SATA Backplane M1245G70 BP6 PAT...

Page 81: ...www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more W...

Page 82: ...er maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufa...

Reviews: