2.4 Rack Mounting
After installing the necessary components, the FT48A-B7070 can be
mounted in a rack using the supplied rack mounting kit.
Rack mounting kit
Rail with Bracket x 2
Mounting Ears x 2
Screw Sack x 1
2.4.1 Installing the Server in a Rack
Follow these instructions to mount the FT48A-B7070 into an industry
standard 19” rack.
NOTE:
Before mounting FT48A-B7070 in a rack, be sure that all internal
components have been installed and the unit has been fully tested. Maintenance
can be performed on the unit while in a rack but it is preferable to install the device
in a fully operational condition.
Screw Sack Including:
A: Bracket for M6 screw--10 pcs
B: M 6--10 pcs
C: M 4-L5--16 pcs
A B C
Installing the Inner Rails to the Unit
Step1: Screw the mounting ears to each side of the FT48A-B7070 as
shown using three M4-L5 screws (C) from the supplied screws kit.