TYAN B5630G86CV12 Service Engineer'S Manual Download Page 107

 

http://www.tyan.com 

107 

4.5.3.1      Memory Topology   

 

 

Read only. 
 

Summary of Contents for B5630G86CV12

Page 1: ...http www tyan com 1 GT86C B5630 Service Engineer s Manual...

Page 2: ...ing liability or warranties relating to fitness for a particular purpose or merchantability TYAN retains the right to make changes to produce descriptions and or specifications at any time without not...

Page 3: ...les These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate rad...

Page 4: ...Do not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer D...

Page 5: ...ndard parts list and accessories describes the external components gives a table of key Chapter2 Setting Up This chapter Covers procedures on installing the CPU memory modules add on card and hard dri...

Page 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Page 7: ...n Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Caution Slide mounted equ...

Page 8: ...Conductive foreign objects can produce a short circuit and cause fire electric shock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid inju...

Page 9: ...t cause damage to the equipment Make sure the product is properly matted with the rails Products that are improperly matted with the rails might be unstable Verify that the AC power supply branch circ...

Page 10: ...onnect all power cords before servicing the appliance Equipment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and bu...

Page 11: ...all watches rings or loose jewelry when working before removing covers and touching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace...

Page 12: ...g the Chassis Cover 29 2 1 2 Installing the CPU and Heat sink 31 2 1 3 Installing the Memory 33 2 1 4 Installing Hard Drives 36 2 1 5 Installing the Add On Card 41 Chapter 3 Replacing Pre Installed Co...

Page 13: ...9 Save Exit 142 Chapter 5 Diagnostics 144 5 1 Flash Utility 144 5 2 AMIBIOS Post Code Aptio 145 Appendix I Installing IO Plate for OCP Card 153 Appendix II Cable Connection Tables 157 Appendix III FR...

Page 14: ...T86C B5630 server system is capable of offering scalable 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation GT86C B5630 not only empowers your company in...

Page 15: ...ted HDD Interface 12 SATA 6Gb s Internal Drive Bay Type Q ty 2 2 5 easy swap HDD SSD Supported HDD Interface 2 SATA 6Gb s System Cooling Configuration FAN 5 4cm fans Power Supply Type PSU single Input...

Page 16: ...ctor 2 SATA SATA DOM 1 Mini SAS HD 4 ports Controller Intel C621 Speed 6 0 Gb s RAID RAID 0 1 10 5 Intel RSTe Graphic Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspeed AST2500 I O...

Page 17: ...via LAN Storage User Configurable FAN PWM Duty Cycle Console Redirection ACPI sleeping states S4 S5 Operating System OS supported list Please refer to our AVL support lists SuSE Linux SLES VMware ESX...

Page 18: ...b s System Cooling Configuration FAN 5 4cm fans Power Supply Type RPSU Input Range AC 110 240V 8 4A Frequency 47 63 Hz Output Watts 500 Watts Efficiency PFC 80 plus gold Redundancy 1 1 Processor Socke...

Page 19: ...d AST2500 I O Ports USB 2 USB3 0 ports at rear 1 USB3 0 TYPE A COM 1 DB 9 COM port VGA 1 D Sub 15 pin port RJ 45 1 GbE port dedicated for IPMI TPM Optional TPM Support Please refer to our TPM supporte...

Page 20: ...ort lists SuSE Linux SLES VMware ESX Windows Server 2008 2008 R2 Red Hat Enterprise Linux Server Regulation CE DoC Class A VCCI Class A CB LVD Yes RCM Class A FCC DoC Class A Operating Environment Ope...

Page 21: ...ed 1 M2091 Riser Board pre installed GT86C B5630 B5630G86CV12 Box Content 1 1U barebone with 12 easy swap HDD bays 1 2 5 easy swap HDD SSD HDD bays 1 500W PSU 1 S5630GMR system Board pre installed 5 S...

Page 22: ...3 2 System Rear View B5630G86CV12 B5630G86CV12R No Description 1 500W Power Supply 2 ID LED Button 3 Serial Port 4 Type A USB 3 0 Ports 5 Optional OCP LAN card location 6 D sub VGA Port 7 1Gb RJ45 LAN...

Page 23: ...LAN Link Activity LED Scheme Left LED Link Activity Right LED Speed No Link OFF OFF 10 Mbps Link Solid Green OFF Active Blinking Green OFF 100 Mbps Link Solid Green Solid Green Active Blinking Green S...

Page 24: ...available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM population gu...

Page 25: ...http www tyan com 25 1 3 5 Internal View...

Page 26: ...SSD Hard Disk tray 7 3 M7051G86 BP6 4 HDD Backplane 2 5 System fans 8 PCIE 3 0 Slot x16 3 Riser Card bracket 9 OCP A Slot J36 4 500W PSU 10 OCP B Slot J37 5 CPU socket 11 1 Internal 2 5 HDD SSD Hard D...

Page 27: ...tools can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A groun...

Page 28: ...metal chassis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre install...

Page 29: ...ard including CPUs memory modules and Add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove GT86C B5630 chassis cover 1 Remove the side screw on the chassis cover as in the...

Page 30: ...http www tyan com 30 2 Push the cover in the direction of the arrow and take out the top cover from chassis kit...

Page 31: ...CPU and Heat sink Follow the steps below on installing CPUs and CPU heat sinks 1 Locate the CPU socket Remove the CPU protection cap 2 Put the Narrow Fabric processor on the Carrier hook clips 3 Align...

Page 32: ...heatsink 5 Align the heatsink on the CPU socket by the guide pins and make sure the gold arrow is located in the correct direction Then place the heatsink onto the top of the CPU socket 6 To secure t...

Page 33: ...odules onto the motherboard 1 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly...

Page 34: ...PU0_DIMM_C0 CPU0_DIMM_C1 CPU0_DIMM_D0 CPU0_DIMM_D1 CPU0_DIMM_E0 CPU0_DIMM_E1 CPU0_DIMM_F0 CPU0_DIMM_F1 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Pop...

Page 35: ...ory All installed memory will automatically be detected and no jumpers or settings need changing All memory must be of the same type and density DDR4 Memory POR Physical Ranks are used to calculate DI...

Page 36: ...5 HDD SSD Follow these instructions to install a hard drive 3 5 Hard Disk Drive Installation 1 Press the lock lever to push the Hard Disk tray in the direction of the arrow to release the HDD tray 2 T...

Page 37: ...http www tyan com 37 3 Place a hard drive into the drive tray Use four screws to secure the HDD 4 Reinsert the HDD tray into the chassis...

Page 38: ...ss the lock lever to push the Hard Disk tray in the direction of the arrow to release the HDD tray 2 Take out the Hard Disk tray Notice that move the rubber screw into the 2 5 location 3 Place a hard...

Page 39: ...Reinsert the HDD tray into the chassis Installing Slim type 2 5 HDD SSD Optional 1 Lift up the locking lever to release the 2 5 HDD SSD bracket 2 Insert the 2 5 hard drives into the bracket and secure...

Page 40: ...http www tyan com 40 3 Position the HDD bracket in its original place Screw it firmly to the chassis Connect the SATA signal cables and the HDD power cables And press down the locking lever...

Page 41: ...rd into the expansion slot which is available with riser card The following instructions are for Add On card installation You may refer to the procedures below for the installation 1 Remove the screw...

Page 42: ...http www tyan com 42 4 Reinstall the riser bracket to the chassis...

Page 43: ...sing the supplied rack mounting kit Rack mounting kit 1 Sliding Rails x 2 2 Screws Kit x 1 2 2 1 Installing the Server in a Rack Follow these instructions to mount the TYANGT86C B5630 into an industry...

Page 44: ...Draw out the inner rail from the rail assembly When the rail comes to a stop pull the tab to release the latch and completely draw the inner rail out 2 Align the inner sliding rail on one side of the...

Page 45: ...ure the outer rail to the rack using 8 M5 washer A screws for each side 2 2 4 Rack mounting the Server 1 Lift the unit and then insert the inner slide rails into the middle rails Press the white butto...

Page 46: ...http www tyan com 46 2 Secure the chassis to the rack by rotate the thumb screws...

Page 47: ...ntroduction This chapter explains how to replace the pre installed components including the S5630GMR Motherboard M7051G86 BP6 4 Backplane M2091 Riser Card System Fan and Power Supply etc 3 2 Disassemb...

Page 48: ...remove the chassis cover Follow Chapter 2 1 1 to remove the cover of GT86C B5630 3 4 Replacing the Riser Card 1 TheGT86C B5630 has preinstalled 1 M2091 riser cards Release the 2 screw to lift the rise...

Page 49: ...com 49 3 5 Replacing the System Fan 1 GT86C B5630 has equipment with five system fans which you need to replace up 2 Disconnect all the fan cables and take out the fan 3 Take out the rubbers to repla...

Page 50: ...ipment with three HDD Backplanes Follow these instructions to replace the M7051G86 BP6 4 HDD Backplane 1 First located at the three HDD Backplane 2 Disconnect all the cables connected to the HDD Backp...

Page 51: ...A PCIe HDD Connectors 1 MINI SAS Connector connect to MB 1 4Pin power connector connect to MB 3 6 2 Connector Definition Location Definition J1 J2 J4 J5 J3 SGPIO1 PW2 SAS SATA HDD Connector SAS SATA H...

Page 52: ...an com 52 3 7 Replacing the Power Supply To replace the power supply follow these instructions B5630G86CV12 1 Disconnect the power cables from and the M7051 2 Disconnect the power cables from and the...

Page 53: ...3 Remove ten 5 screws that secure the power supply to the chassis 4 Lift the whole power supply unit up from the chassis 5 Take out the whole power supply 6 Install a new power supply unit following...

Page 54: ...http www tyan com 54 B5630G86CV12R 1 Located at the power supply usage 2 Press the lab to free the power from the power socket...

Page 55: ...http www tyan com 55 3 Replace a new power supply and reinsert it into the power socket following the above steps in reverse...

Page 56: ...After removing all of the aforementioned cables follow these instructions to remove the motherboard from the chassis 1 Disconnect SATA and USB cables 2 Disconnect the power cable and PSMI Cable 3 Disc...

Page 57: ...to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are...

Page 58: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 4 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Page 59: ...options listed below are for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Product Name It displays Product information BIOS V...

Page 60: ...formation It displays the total memory size Memory Frequency It displays Memory frequency System Date Set the Date Use Tab to switch between Date elements Default Ranges Year 2010 2079 Months 1 12 Day...

Page 61: ...nfigure the iSCSI parameters Intel R Virtual RAID on CPU This formset allows the user to manage Intel R Virtual RAID on CPU Trusted Computing Trusted Computing settings ACPI Settings System ACPI Param...

Page 62: ...ole Redirection Serial Port Console Redirection Option ROM Dispatch Policy Option ROM Dispatch Policy PCI Subsystem Settings PCI PCI X and PCI Express Settings Network Stack Configuration Network Stac...

Page 63: ...http www tyan com 63 4 3 1 iSCSI Configuration iSCSI Initiator Name The worldwide unique name of iSCSI Initiator Only IQM format is accepted Range is from 4 to 223...

Page 64: ...IO Configuration Intel VMD technology Intel VMD for Volume Management Device on Socket 0 for CPU0 Socket 1 for CPU1 Intel VMD for Volume Management Device for PStack0 Slot 1 4 PStack1 Slot 5 8 PStack2...

Page 65: ...ed Computing Security Device Support Enable or Disable BIOS support for security device O S will not show Security device O S will not show Security Device TCG EFI protocol and INT1A interface will no...

Page 66: ...ACPI Auto Configuration Enable or Disables BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enables or Disables System ability to Hibernate OS S4 Sleep state This option may not be ef...

Page 67: ...www tyan com 67 4 3 5 Hardware Health Configuration Auto Fan Control Auto Fan Control help Disabled Enabled BMC Alert Beep Enable Disable BMC Alert Beep On Off PMBus support PMBus Support Disabled Ena...

Page 68: ...68 4 3 5 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Page 69: ...http www tyan com 69...

Page 70: ...http www tyan com 70 4 3 6 Onboard Device Configuration Chassis Intrusion Detection Enabled When a chassis open event is detected the BIOS will display the event Disabled Enabled...

Page 71: ...http www tyan com 71 4 3 7 AST2500 Super IO Configuration Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA Serial Port 2 Configuration Set Parameters of Serial Port 2 COMB...

Page 72: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6...

Page 73: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6...

Page 74: ...tings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select dynamic time system will wake on the current time increase...

Page 75: ...l Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the ho...

Page 76: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with t...

Page 77: ...rt Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled Resolu...

Page 78: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with t...

Page 79: ...stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent...

Page 80: ...http www tyan com 80 4 3 9 3 Legacy Console Redirection Settings Legacy Serial Redirection Port Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM1 COM2...

Page 81: ...r OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setti...

Page 82: ...n sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses tw...

Page 83: ...re if Failure If system fails to boot and this option is set to Enabled software will reset settings of this page as well as CSM page to its default values automatically Disabled Enabled PCIE_1 Empty...

Page 84: ...or Disables 64bit capable Devices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this opt...

Page 85: ...http www tyan com 85 4 3 12 Network Stack Configuration Network Stack Enable Disable UEFI Network Stack Enabled Disabled...

Page 86: ...Current Boot option filter This option controls Legacy UEFI ROMs priority UEFI and Legacy Legacy only UEFI only Network Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy S...

Page 87: ...http www tyan com 87 Other PCI devices Determines OpRom execution policy for devices other than network storage or video Do not launch UEFI legacy...

Page 88: ...bled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support...

Page 89: ...vice reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Hos...

Page 90: ...http www tyan com 90 4 4 Platform Configuration PCH Configuration Displays and provides option to change the PCH Settings Server ME Configuration Configure Server ME Technology Parameters...

Page 91: ...uration settings PCH SATA Configuration SATA devices and settings PCH sSATA Configuration sSATA devices and settings USB Configuration USB Configuration Settings PCH DFX Configuration PCH DFX Configur...

Page 92: ...Express Root Port Enabled Disabled PCIE ASPM PCI Express Root port ASPM Setting Disable ASPM ASPM L1 ASPM Auto L1 Substates PCI Express L1 Substates settings Disabled L1 1 L1 2 L1 1 L1 2 PCIe Speed Co...

Page 93: ...Disabled Configure SATA as Determines how SATA controller s operate AHCI RAID SATA Port 0 1 2 3 4 5 6 7 Port 0 1 2 3 4 5 6 7 Enable or Disable SATA Port Disabled Enabled Hot Plug Designates this port...

Page 94: ...nabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid State Drive or Hard disk Drive Hard Disk Drive Solid Sta...

Page 95: ...http www tyan com 95 4 4 1 3 PCH sSATA Configuration...

Page 96: ...port as External SATA eSATA Disabled Enabled Spin Up Device If enabled for any of ports Staggered Spin Up will be performed and only the drives witch have this option enabled will spin up at boot Oth...

Page 97: ...97 4 4 1 4 USB Configuration XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect...

Page 98: ...abled ADR GPIO Select between GPIO_B or GPIO_C GPIO_B GPIO_C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Enabled Disabled Enable Disable ADR Timer Held off for DEBUG P...

Page 99: ...http www tyan com 99 ADR timer multiplier Select proper ADR timer multiplier x1 8 24 40 56 64 72 80 88 96 x1 x8 x24 x40 x56 x64 x72 x80 x88 x96...

Page 100: ...http www tyan com 100 4 4 2 Miscellaneous Configuration Active Video Select active video type Auto Onboard Device PCIE Device...

Page 101: ...http www tyan com 101 4 4 3 Server ME Configuration Read only...

Page 102: ...e Configuration Displays the provides option to change the Common RefCode Settings Memory Configuration Displays and provides option to change the Memory Settings IIO Configuration Displays and provid...

Page 103: ...ax CPUID Value Limit This should be enabled in order to boot legacy OSes that cannot support CPUs with extended CPUID functions Disabled Enabled Execute Disable Bit When disabled forces the XD feature...

Page 104: ...d Lock Chipset Lock or Unlock chipset Disabled Enabled Hardware Prefetcher MLC Streamer Prefetcher MSR 1A4h Bit 0 Enabled Disabled Adjacent Cache Prefetch MLC Spatial Prefetcher MSR 1A4h Bit 1 Enabled...

Page 105: ...O High Base 56T 40T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up to 32xgranularity Per stack mmioh resource ass...

Page 106: ...this feature Auto Sets it to the MRC default setting current default is Enable Auto POR Disable Memory Frequency Maximum Memory Frequency selections in Mhz Do not select Reserved Auto 1866 2133 2400...

Page 107: ...http www tyan com 107 4 5 3 1 Memory Topology Read only...

Page 108: ...LM Mirror Mode 2LM Mirror TAD0 Enable Mirror on entire memory for TAD0 Enabled Disabled Enable Partial Mirror Partial mirror mode will enable the required size of memory to be mirrored If rank sparing...

Page 109: ...Threshold 1 32767 used for sparing tagging and leaky bucket 10 SDDC Plus One Enable Disable SDDC Plus One Disabled Enabled ADDDC Sparing Enable Disable ADDDC Sparing Disabled Enabled Patrol Scrub Enab...

Page 110: ...n menu Intel VMD Technology Press Enter to bring up the Intel VMD for Volume Management Device Configuration menu PCIe Hot Plug Enable Disable PCIe Hot Plug globally Disabled Enabled Auto Manual PCIe...

Page 111: ...http www tyan com 111 PCIe Access Control Services Enable or disable Access Control Services ACS in PCIe Downstream Switch Port Disabled Enable...

Page 112: ...furcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 Auto IDU2 IIO PCIe Br3 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 Auto Socket 0 PcieBr1D00F0 Port 1...

Page 113: ...Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 5A Socket 0 PcieBr3D02F0 Port 3C Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 5A Socket 0 PcieBr3D02F0 Port 3D...

Page 114: ...to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable This optio...

Page 115: ...PCIe port Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled I...

Page 116: ...s used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled Surprise Hot Plug Capable Thi...

Page 117: ...downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state Disabled Enabled 4 5 5 1 3 Socket 0 PcieBr2D00F0 Port 3B 3C 3D PCI E Port In auto mode th...

Page 118: ...abled PCI E Port Link This option disables the link so that the no training occurs but the CFG space is still active Enabled Disabled Link Speed Choose Link Speed for this PCIe port Auto Gen 1 2 5 GT...

Page 119: ...ed to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Disabled Enabled PCI E Port Link This option disab...

Page 120: ...L1 support for the downstream devices Auto L1 Only Disabled L0s Support When disabled IIO never puts its transmitter in L0s state Disabled Enabled 4 5 5 2 Intel VT for Directed I O VT d Intel VT for D...

Page 121: ...http www tyan com 121 4 5 5 3 Intel VMD Technology...

Page 122: ...Volume Management Device Technology in this Stack Disabled Enabled Intel VMD for Volume Management Device VMD Config for PStack1 Enable Disable Intel Volume Management Device Technology in this Stack...

Page 123: ...ion CPU P State Control P State Control Configuration Sub Menu include Turbo XE and ete Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting Package C State Contr...

Page 124: ...state that the BIOS will set before OS hand off Max Performance Max Efficient Set by Intel Node Manager Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Enabled Disabled Turbo Mode E...

Page 125: ...ore Ratio Multiplier 23 4 5 5 4 2 Hardware PM State Control Hardware P States Disable Hardware chooses a P state based on OS Request Legacy P States Native Mode Hardware chooses a P state based on OS...

Page 126: ...rol CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Disabled Enabled Auto Enhanced Halt State C1E Core C1E auto promotion Control Takes effect after reboot Disabled Enabled OS ACPI Cx Report...

Page 127: ...http www tyan com 127 4 5 5 4 4 Package C State Control Package C State Package C State limit C0 C1 state C2 state C6 non Retention state C6 Retention state No Limit Auto...

Page 128: ...http www tyan com 128 4 5 5 4 5 CPU T State Control Software Controlled T States Enable Disable Software Controlled T States Disabled Enabled...

Page 129: ...figure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing Reset Power Down Power Cycle OS Watchdog Timer If enabled starts a BIOS timer which...

Page 130: ...minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog timer is disabled Do Nothing Reset Power Down Power Cycle BM...

Page 131: ...nts is set to Disabled the following items are read only Erase SEL Choose options for erasing SEL No Yes on next reset Yes on every reset When SEL is Full Choose options for reactions to a full SEL Do...

Page 132: ...http www tyan com 132 4 6 2 BMC Network Configuration...

Page 133: ...parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Configuration Ad...

Page 134: ...key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm Ne...

Page 135: ...activated when Platform Key PK is enrolled System mode is User Deployed and CSM function is disabled Disabled Enabled Secure Boot Mode Secure Boot mode selector Standard Custom In Custom mode Secure...

Page 136: ...Press Yes to install factory default keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 has of the binary into Authorized signature Database db Save All Secure Boot Variabl...

Page 137: ...Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 bin 2...

Page 138: ...256 Key source Default External Mixed Test Set New Append OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X50...

Page 139: ...0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Wait for ESC If Error Wait for ESC key...

Page 140: ...http www tyan com 140 Boot Option Priorities Boot Option 1 3 Select the first second boot device Device Name Disabled Network Device BBS Priorities Set the order of the legacy devices in this group...

Page 141: ...http www tyan com 141 4 8 1 Network Device BBS Priorities Boot Option 1 Set the system boot order Device Name Disabled...

Page 142: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Page 143: ...http www tyan com 143 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Read only...

Page 144: ...5 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Page 145: ...0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used P...

Page 146: ...orth Bridge module specific 0x18 Pre Memory North Bridge initialization North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre Memory South Bridge initialization...

Page 147: ...outh Bridge initialization South Bridge module specific 0x3E Post Memory South Bridge initialization South Bridge module specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE PIL is started...

Page 148: ...forced recovery 0xF2 Recovery process started 0xF3 Recovery firmware image is found 0xF4 Recovery firmware image is loaded 0xF5 0xF7 Reserved for future AMI progress codes Recovery Error Codes 0xF8 Re...

Page 149: ...n North Bridge module specific 0x6F North Bridge DXE initialization North Bridge module specific 0x70 South Bridge DXE initialization is started 0x71 South Bridge DXE SMM initialization is started 0x7...

Page 150: ...A8 Setup Verifying Password 0xA9 Start of Setup 0xAA Reserved for ASL see ASL Status Codes section below 0xAB Setup Input Wait 0xAC Reserved for ASL see ASL Status Codes section below 0xAD Ready To Bo...

Page 151: ...ion 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is n...

Page 152: ...http www tyan com 152 Status Code Description 0xAA System has transitioned into ACPI mode Interrupt controller is in APIC mode...

Page 153: ...Plate for OCP Card Follow these instructions to install the IO Plate for OCP Card Here shows how to install the IO Plate for the dual port LAN card M7106 X557 2T2E 1 Unscrew the riser card bracket 2...

Page 154: ...semi shearing for the OCP card slot Discharge the metal slug 4 Take out the IO plate for LAN card Use a screwdriver to break the LAN port s semi shearing Break one semi shearing if a single port LAN...

Page 155: ...http www tyan com 155 5 Insert the IO Plate to the OCP card LAN port 6 Screw the IO Plate to the chassis...

Page 156: ...http www tyan com 156 7 Insert the LAN card into the OCP slot 8 Secure the LAN card to the chassis...

Page 157: ...BP6 4 Connect to S5630 Mini SAS HD to Mini SAS Cable J3 sSATA 0_3 Mini SAS HD to Mini SAS Cable J3 SATA 0_3 Mini SAS HD to Mini SAS Cable J3 SATA 4_7 3 SATA Cable M7051G86 BP6 4 BP to S5630 MB Cable S...

Page 158: ...2 PSMI P8 PSIMI1 SINGLE PSU to M7051G86 BP6 4 BP SINGLE PSU Connect to M7051G86 BP6 4 B4P P3 PW2 B4P P4 PW2 B4P P5 PW2 6 Power Supply Cables FOR B5630G86CV12R RPSU to S5630 MB RPSU PSU Connect to S563...

Page 159: ...ATA CABLE SAS WIRE SATA 7P 180 SATA 7P 180 GT56 B7066 FRU CS 0330 332810000514 TF POWER CORD SBU US 125 V 16 AWG 1 31mm 1800mm AC PWR CORD CCBL 0300 332810000281 TF PWR CORD SBU EU 250 V H05VV FX3C 10...

Page 160: ...http www tyan com 160 NOTE...

Page 161: ...expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports...

Page 162: ...roper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manu...

Reviews: