These instructions should be read in full before the RF amplifier is 
operated. 
 
The safety and operating instructions should be retained for future 
reference. 
 
All warnings on the RF amplifier and in the operating instructions 
should be adhered to. 
 
All operation and user instructions should be followed.  
 
Use of this device into a radiating antenna requires a valid licence from 
a Spectrum Management Authority in most countries. 
 
Use of this device as part of a transmission system, or combined 
transmission system not specified by the manufacturer, may require 
further testing to ensure that it remains compliant with the essential 
requirements and other relevant provisions of current EU Low Voltage, 
EMC and Radio Equipment Directives. Approval and clearance from the 
Spectrum Management Authority may also be required.  
 
Installation must adhere to safety regulations and the requirements of 
the relevant authorities. We recommend that at least two people are 
present during installation. Keep a file containing installation 
instructions and plans, including details of the transmission system 
(antennas, feeders, filters, etc) and operating instructions for all 
equipment at the transmission site at all times. Display posters 
detailing first aid treatment and treatment for electrical shock, along 
with telephone numbers for contacting the emergency services in the 
event of personal injury.  
 
Ensure antenna system lightning strike protection is in place. 
 
To reduce the risk of electrical shock, do not remove the cover, or any 
screws. There are no user serviceable parts inside; refer servicing to 
qualified personnel. 
 
Do not expose this appliance to rain or moisture. The RF amplifier 
should not be used near water. Care should be taken so that objects 
do not fall - and liquids are not spilled - into the enclosure through 
openings.  

Before operating 

Summary of Contents for TXAMP200

Page 1: ...fields cannot exceed safe limits The permitted limits vary from country to country Expert advice should be sought about the safe installation of this transmission system RISK OF FIRE RF Radio Frequenc...

Page 2: ...rotected against antenna load faults MIS OPERATION MAY RESULT IN DAMAGE NOT COVERED BY ANY WARRANTY IMPORTANT Correct operation of the cooling fans in this product is vital to reliable continuous oper...

Page 3: ...amplifiers are used by broadcasters worldwide and benefit from 25 years of engineers design experience The TXAMP200 uses the latest MOSFET devices achieving new levels of efficiency and reliability T...

Page 4: ...Installation must adhere to safety regulations and the requirements of the relevant authorities We recommend that at least two people are present during installation Keep a file containing installati...

Page 5: ...Precautions should be taken so that the grounding or polarisation of this appliance is not defeated The unit should be cleaned only as recommended by the manufacturer The RF amplifier should be servic...

Page 6: ...r measuring compliance 4 PSU DC OK This LED indicates that the Power Amplifier Supply 48V DC is working 5 PSU AC OK This LED indicates that the AC mains power is connected 6 SYSTEM If this LED is gree...

Page 7: ...gulations 13 REMOTE This 9 way D sub socket can be used for remote control and monitoring of the RF amplifier It also enables automatic switching of N 1 back up system configurations Pin 1 This output...

Page 8: ...output setting press and hold the OK key for 3 seconds The TXAMP200 will enter LOCAL mode and the FWD Power level will be highlighted Press the UP or DOWN buttons to select the desired output power t...

Page 9: ...e clearance and cooling airflow Use front to back rack supports on both sides of the RF amplifier and slide the unit into the rack NEVER ALLOW THE FRONT PANEL FIXINGS TO TAKE THE WEIGHT OF THE UNIT Fi...

Page 10: ...is designed for continuous reliable transmission however the fans air vents and air tunnels must be periodically checked for correct operation and free airflow The cooling fans should be replaced aft...

Page 11: ...ddress in the address bar of an internet browser IMPORTANT Accessing the RF amplifier s front panel menu will enter the TXAMP200 into local mode where front panel settings take precedence over the eth...

Page 12: ...can be ignored because hardware devices don t usually serve https secure pages to clients However general network security is VERY IMPORTANT It is up to the user to ensure adequate overall security f...

Page 13: ...es RF Monitoring RF monitor front panel BNC 50 ohm approx 40dB Remote I O I O Control 9 way D sub female Network LAN TCP IP RJ45 Power Supply Voltage 100 240Vac 50 60Hz Consumption Mechanical Dimensio...

Page 14: ...nts of Directive 2014 53 EU and is CE marked accordingly Low Voltage Directive EN60215 Safety Requirements for Radio Transmitting Equipment ERM EMC ETSI EN 302 077 V2 2 0 Transmitting equipment for th...

Page 15: ...contact your local or regional waste administration IMPORTANT NO REPRESENTATIONS OR WARRANTIES EITHER EXPRESS OR IMPLIED OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE...

Page 16: ...respect to this information TX Digicast specifically disclaims the implied warranty of merchantability and fitness for a particular purpose TX Digicast Clay Pit Lane Bar Lane Industrial Estate Roecli...