The IP address and associated network configurations can be changed 
by selecting the settings (‘gear’) icon: 
   

 

 
DCHP can be set, or a new IP address entered. Include the Gateway 
address of the local Router, and the desired Primary and Secondary 
DNS server addresses, if different. 
 
New browser sessions will prompt for a Username and Password. 
When continuing within the current browser session there will be no 
prompt to enter a Username or Password. 
 
Like most ethernet enabled devices, the client web browser may flag 
the internet connection as 'Not secure'. This can be ignored, because 
hardware devices don't usually serve ‘https’ (secure) pages to clients. 
 
However, general network security is VERY IMPORTANT. It is up to the 
user to ensure adequate overall security for the internet connection. 
Like all computers, on all networks, the transmitter's network port will 
be continually subject to external hack and ‘Ping of Death’ attacks. 
Connect the transmitter’s network port to the Internet via a Router 
with port forwarding configured in such a way as to ensure maximum 
local network security. Schedule regular checks, on an on-going basis, 
to ensure that the Router is running the very latest manufacturer’s 
firmware. 
 
TX Digicast take no liability whatsoever for damage or losses caused by 
a successful network attack. 
 

 

Summary of Contents for DABTX200

Page 1: ...by any person to RF fields cannot exceed safe limits The permitted limits vary from country to country Expert advice should be sought about the safe installation of this transmission system RISK OF F...

Page 2: ...otected against antenna load faults MIS OPERATION MAY RESULT IN DAMAGE NOT COVERED BY ANY WARRANTY IMPORTANT Correct operation of the cooling fans in this product is vital to reliable continuous opera...

Page 3: ...ers are used by broadcasters worldwide and benefit from 25 years of engineers design experience At the heart of the TXDAB200 is a high quality COFDM modulator and the RF Power Amplifier uses the lates...

Page 4: ...Installation must adhere to safety regulations and the requirements of the relevant authorities We recommend that at least two people are present during installation Keep a file containing installati...

Page 5: ...Precautions should be taken so that the grounding or polarisation of this appliance is not defeated The unit should be cleaned only as recommended by the manufacturer The transmitter should be service...

Page 6: ...or measuring compliance 4 PSU DC OK This LED indicates that the Power Amplifier Supply 48V DC is working 5 PSU AC OK This LED indicates that the AC mains power is connected 6 SYSTEM If this LED is gre...

Page 7: ...oint in accordance with local regulations 13 REMOTE This 9 way D sub socket can be used for remote control and monitoring of the transmitter It also enables automatic switching of N 1 back up system c...

Page 8: ...nnector The filter output should be connected to this socket via a suitable coupling mechanism This allows the modulator to automatically optimise the COFDM signal to compensate for the mask filter s...

Page 9: ...transmission parameters Press the down key to see the remaining items To enter the settings menu press and hold the OK key for 3 seconds The DABTX200 will enter LOCAL mode and the following settings w...

Page 10: ...esponding setting will now be highlighted Press the UP and DOWN buttons to selected the desired setting and then press ENTER to store it When selecting EDI1 or EDI2 parameters a new screen will appear...

Page 11: ...UT socket on the transmitter s rear panel Connect the EDI feed s GPS antenna and then the mains lead Switch on the mains power Press the OK key for 3 seconds to enter the settings menu Select the RF P...

Page 12: ...nput if required and enter the required network settings Press OK to store the values The transmitter has a TEST MODE If enabled the COFDM modulator will transmit a test signal For normal operation en...

Page 13: ...ion system may shut down its RF output and will in any case require URGENT attention The transmitter is designed for continuous reliable transmission however the fans air vents and air tunnels must be...

Page 14: ...ddress in the address bar of an internet browser IMPORTANT Accessing the transmitter s front panel menu will enter the TXDAB200 into local mode where front panel settings take precedence over the ethe...

Page 15: ...s can be ignored because hardware devices don t usually serve https secure pages to clients However general network security is VERY IMPORTANT It is up to the user to ensure adequate overall security...

Page 16: ...50 ohm approx 40dB Remote I O I O Control 9 way D sub female Inputs EDI1 RJ45 TCP IP Ethernet EDI2 RJ45 TCP IP Ethernet GPS input SMA female Sense input SMA female Network LAN TCP IP RJ45 Power Suppl...

Page 17: ...ents of Directive 2014 53 EU and is CE marked accordingly Low Voltage Directive EN60215 Safety Requirements for Radio Transmitting Equipment ERM EMC ETSI EN 302 077 V2 2 0 Transmitting equipment for t...

Page 18: ...contact your local or regional waste administration IMPORTANT NO REPRESENTATIONS OR WARRANTIES EITHER EXPRESS OR IMPLIED OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE...

Page 19: ...respect to this information TX Digicast specifically disclaims the implied warranty of merchantability and fitness for a particular purpose TX Digicast Clay Pit Lane Bar Lane Industrial Estate Roecli...

Reviews: