IonGuard Disinfection & Purification System

Pool • Spa • HVAC Water Treatment & Conditioning 

Commercial / Industrial Model# 

TWT-5C8-277-0.5 Amp • TWT-5C8-278-1.25 Amp • TWT-5C8-279-2 Amp

OWNER APPLICATION & INSTALLATION MANUAL

The TWT

®

systems will give many years of service if sized and installed properly.

Please read all instructions carefully before assembling the system.

SEE PAGE 9-10: INSTRUCTIONS FOR THE USE OF TWT

®

DEPOSIT CONTROL TECHNOLOGY

If you have purchased model#

TWTDCI-5C8-377 • TWTDCI-5C8-378 • TWTDCI-5C8-379

integrated deposit control and ionization treatment system

Note: IonGuard operational instructions are the same for all listed treatment systems

Do not discard operating manual, keep in equipment room for reference

M57

Summary of Contents for IonGuard TWT-5C8-277-0.5 Amp

Page 1: ...systems will give many years of service if sized and installed properly Please read all instructions carefully before assembling the system SEE PAGE 9 10 INSTRUCTIONS FOR THE USE OF TWT DEPOSIT CONTRO...

Page 2: ...cal Power Section 8 Steps to Put the IonGuard System in Service Section 9 Adjusting the IonGuard System Section 10 Replacing the Ionization Electrodes Section 11 Trouble Shooting IonGuard System Secti...

Page 3: ...Power cord electrical wires and extra fuse Copper Test Kit Please Note See page 9 10 For maximum efficiency the Triangular Wave IonGuard Purification System should be installed with the Triangular Wa...

Page 4: ...source generators power other ionization units In all ionization units copper and silver ions plate off of the electrodes and enter the water Over time the electrodes will become smaller and the gap b...

Page 5: ...ecommended Power Supply Electronic Control Unit T Housing Electrodes Isolation Valve Isolation Valve Not included See section 3 regarding installation TWT Deposit Control System Recommended TWT IonGua...

Page 6: ...provided with the Ionization system should be left in place on the two interlock standby terminals If the jumper wire is removed the Ionization system will go to standby mode LowVoltage Circuit Connec...

Page 7: ...operate the control unit at the proper power level With some variation operating the control unit between 10 and 30 power level should maintain the proper disinfec tion copper level of 0 25 to 0 35 p...

Page 8: ...an acceptable level electrodes must be replaced REPLACING THE IONIZATION ELECTRODES SECTION 10 Notes Use the following steps to change the ionization electrodes 1 Shut off power to all systems 2 Shut...

Page 9: ...a maximum output voltage of 24 vdc When this voltage can not provide the set current value the unit will go into alarm To set the desired current you must select the set current display 1 push of disp...

Page 10: ...ve Technologies Inc IF DO Low Copper Reading Increase set current Low Copper Reading with Clean or replace electrodes Control Unit Full On High Copper Level Decrease set current Display is Inoperative...

Page 11: ...WT DEPOSIT CONTROL TECHNOLOGY TWT Deposit Controller Solenoid Coil Terminal Hookup Factory Wrapped Wire Coil Reaction Chambers Application To use in conjunction with the TWT Deposit Control Systems Tr...

Page 12: ...equip ment that is idle Of course the system can and should be disconnected from the power source when being directly handled for installation removal sea sonal shutdown or for other major equipment r...

Page 13: ...suffered corrosion prior to the installation of a TWT Deposit Control System the removal of this scale may potentially reveal cracks pinholes in this piping or equipment that had been held together by...