TWINBIRD SC-UE15 Operation Manual Download Page 8

Ref. No. TB-00006168-2 

 

 

   

TWINBIRD CORPORATION      http://fpsc.twinbird.jp

 

 

(8/15) 

4. 

基本的な使い方

 

4.1 

準備

 

(1)

電源:電圧

DC48V

、定格電流

5A   

ピーク電流が

9A

流れる場合があるので、

9A

以上の容量を持つ電源を

 

準備してください。

 

(2)

温調器と温度センサー

 

(3)

配線材とスイッチ

 

 
4.2 

起動手順

 

(1)DC48V

電源のスイッチを入れる。

 

(2)

駆動基板に取り付けたスイッチを

ON(CLOSE)

にする。

 

 
4.3 

停止手順

 

(1)

駆動基板に取り付けたスイッチを

OFF(OPEN)

にする。

 

      (2)DC48V

電源のスイッチを切る。

 

 
4.4 

配線

  Wiring 

[

電圧入力の場合

  Voltage Input] 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.  Basic Operation 
4.1 Preparation 

(1) Power source: Voltage DC48V, Rating current: 5A   

                                        Prepare power supply output current more than 9A   

for peak current  9A. 

  (2) Temp. controller and Temp. sensor 

        (3) Wire and Switch 
 
4.2 Start Procedure 

(1) Turn on the Switch of Power supply. 
(2) Turn on the Switch of the Drive PCB. 

 
4.3 Stop Procedure 

(1) Turn off the Switch of the Drive PCB. 
(2) Turn off the Switch of Power supply. 

 
[

電流入力の場合

  Current Input] 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DC48V 

電源

 

DC48V Power Supply 


CN8 

CN1 

CN2 

CN6 

CN7 

スイッチ

 

Switch 

温調器

 

Temp. Controller 

FPSC

モジュール

 

FPSC Module 

温度センサー

 

Temp. Sensor 

(1

5V) 

FPSC 

サーミスタ

 

Thermistor 

ブロア

 

Blower 

駆動基板

  Drive PCB 

DC48V 

電源

 

DC48V Power Supply 


CN8 

CN1 

CN2 

CN6 

CN7 

スイッチ

 

Switch 

温調器

 

Temp. Controller 

FPSC

モジュール

 

FPSC Module 

温度センサー

 

Temp. Sensor 

(4

20mA) 

FPSC 

サーミスタ

 

Thermistor 

ブロア

 

Blower 

駆動基板

  Drive PCB 

Summary of Contents for SC-UE15

Page 1: ...Ref No TB 00006168 2 TWINBIRD CORPORATION http fpsc twinbird jp 1 15 Operation Manual Model SC UE15 Name FPSC UE15 FPSC UE15 TWINBIRD CORPORATION...

Page 2: ...xporting Stirling coolers from Japan for abroad Foreign Exchange and Foreign Trade Law section 1 of article 48 Foreign Exchange and Foreign Trade Law section 1 of article 67 Export Trade Control Ordin...

Page 3: ...avoid the possibility of damaging to internal parts by overheating the FPSC Module do not apply heating elements directly to the cold side 4 Use caution to prevent the Heat Reject Fin from being fille...

Page 4: ...Please provide thermal insulation around cold side to prevent frost and dew condensation If conditions require that you need to operate the FPSC Module without thermal insulation the cold side may dev...

Page 5: ...damaged by the short circuit when the backside of the PCB touches some metal parts It may be damaged by static electricity Use caution to prevent damage of backside electric parts 20 In order to impr...

Page 6: ...Ref No TB 00006168 2 TWINBIRD CORPORATION http fpsc twinbird jp 6 15 3 2 Main Size FPSC FPSC Module Drive PCB mm Parts Side Height Solder Side Height...

Page 7: ...5 Output Setting Max 42 5W and over Cold Side Temp 80 deg C 9 Operating Conditions of Temperature and Humidity 3 Ambient Temp 0 40 deg C 10 Cold Side Temp 120 70 deg C 11 Warm Side Temp 0 70 deg C 12...

Page 8: ...ller and Temp sensor 3 Wire and Switch 4 2 Start Procedure 1 Turn on the Switch of Power supply 2 Turn on the Switch of the Drive PCB 4 3 Stop Procedure 1 Turn off the Switch of the Drive PCB 2 Turn o...

Page 9: ...e cold side and the warm side which is called Insulation Area to prevent having frost or condensation Having frost or condensation on the Insulation Area can cause an apparent reduction of cooling cap...

Page 10: ...28 22 AWG Stranded wire 0 08 0 32mm2 28 22 AWG Element wire 0 12mm Min Strip Length 9 10 mm 1 Power Source Input 2 CN2 JST B2B PH K E Blue Acceptable Connector JST PHR 2 1 Warm Side Thermistor 1 Setti...

Page 11: ...le voltage DC 43 2 52 8 V DC 48 V 10 3 Rating current 5A at 48V input CN6 Output to Blower 1 Condition for output While FPSC is driven 2 Output voltage DC 12 V 10 3 Output current capacity 2 A CN7 Pin...

Page 12: ...put 1 High Emergency Power supply to the FPSC and the Fan motor will be stopped 2 Low Normal Emergency situations 1 Temperature sensor at warm side has reached the limit temperature set by SW2 2 Tempe...

Page 13: ...signal output 1 When the temperature of the sensor on the warm side goes down 5 deg C lower than the temperature set by SW1 CN7 Pin7 Alarm signal 2 1 High Alarm 2 Low Normal Situation for alarm signal...

Page 14: ...min00sec 1001 1 step 5 6 sec 23min48sec 1111 1 step 19 2 sec 1h21min36sec 1010 1 step 6 4 sec 27min12sec 1 Select 0101 or bigger Stirling Cooler may operate with rather larger noise and or vibration w...

Page 15: ...Ref No TB 00006168 2 TWINBIRD CORPORATION http fpsc twinbird jp 15 15...

Reviews: