Note, the scale and size of your parts may be different depending on your exact model.

•   The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and require no 

further lubrication. However, we recommend periodic cleaning/vacuuming of the fan/heater.

•   Make sure the unit is turned OFF and unplugged before cleaning the heater or fireplace.

EXPLODED VIEW

CARE AND MAINTENANCE

Part

Part Name

1

Flame Generator Drive Motor

2

Heater/Blower Assembly

3

Main Circuit Board

4

Downlight Circuit Board

5

Control Panel Circuit Board

6

Control Panel Buttons

7

Emberbed with Log

8

Emberbed Circuit Board

9

Flame Circuit Board

10

Blue Flame Circuit Board

11

LCD Display

12

Flame Generator/ Spinner

13

Remote Control 

Summary of Contents for 18EF031GRA

Page 1: ...Made in China Printed in China Fabricado en China Impreso en China Fabriqu en China Imprim en Chine www tsicustomerservice com 1 866 661 1218 MODELS 18EF031GRA 18EF031SRA 23EF031GRA 23EF031SRA 25EF03...

Page 2: ...service 3 Go to www tsicustomerservice com for product warranty registration If you are unable to complete registration save your proof of purchase for warranty purposes Model Mod le Modelo 28EF031GRA...

Page 3: ...in the manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 1 Read all instructions before using this appliance 2 This appliance is hot when in u...

Page 4: ...remote there will be a corresponding indicator displayed The indicator shows the function changed and the level selected When the function is turned off the corresponding indicator will flash several...

Page 5: ...e control panel To change between F and C press and hold the HEATER button on the control panel for 3 seconds Pressing the timer button will cycle through the timer settings 30 minutes 1 Hour 2H 3H 4H...

Page 6: ...he control panel to see if the downlight comes on Power cord gets warm Normal operation Check your heater cord and plug connections Faulty wall outlet connections or loose plugs can cause the outlet o...

Page 7: ...commend periodic cleaning vacuuming of the fan heater Make sure the unit is turned OFF and unplugged before cleaning the heater or fireplace EXPLODED VIEW CARE AND MAINTENANCE Part Part Name 1 Flame G...

Page 8: ...ies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received includin...

Page 9: ...6 The owner user assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out of the use or inability to use the product except as provided by l...

Page 10: ...www tsicustomerservice com A148 10 www tsicustomerservice com...

Reviews: