twin city T080 Instructions Download Page 4

Page 4

1

3

8

6

9

10

2

11

7

12

4

5

KEY PART NO.

DESCRIPTION

1

97013576

Grille

2

97014926

Motor Plate

3

99080518

Motor (T080)

4

99020276

Impeller

5

99260425

Motor Nut (2 req.)

*

97015159

Blower Assembly (includes Key Nos. 2 thru

5) (T080)

6

99270982

Receptacle

7

98009611

Wire Panel

*

97015170

Wire Panel Assembly 

(includes Key Nos. 6 & 7)

8

97014922

Housing

9

97003932

Damper/Duct Connector

10

98008868

Wiring Plate

11

99150575

Screw, #8-18 x .375

12

99150574

Ground Screw

 

 

* Not shown assembled.

Order replacement parts by
“PART NO.” - not by “KEY NO.”

USE AND CARE

SERVICE PARTS

WARRANTY

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND
LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVIC-
ING THIS UNIT.

The motor is permanently lubricated. Do not oil or disassemble
motor.

TO CLEAN GRILLE:

CAUTION:

 Plastic parts can be cleaned with mild, soapy water (use

a mild detergent, such as dishwashing liquid) and dried with a soft
cloth.

 Do not use abrasive cloth, steel wool pads, or scouring

powders.

TO CLEAN FAN ASSEMBLY:

Unplug fan assembly. To remove motor plate: Find the single tab on
the motor plate (located next to the receptacle). Push up near motor
plate tab while pushing out on side of housing. Or insert a straight-
blade screwdriver into slot in housing (next to tab) and twist
screwdriver. Gently vacuum fan, motor and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IM-
MERSED IN WATER.

99042959B

Limitation of Warranties and Claims

Seller warrants to the original purchaser that the goods sold hereunder shall be
free from defects in workmanship and material under normal use and service
(except in those cases where the materials are supplied by the buyer) for a period
of one year from the date of original installation or eighteen (18) months from the
date of shipment, whichever occurs first. The liability of seller under this warranty
is limited to replacing, repairing, or issuing credit (at cost, F.O.B. factory and at
seller’s discretion) for any part or parts which are returned by buyer during such
period provided that:
a. seller is notified in writing within ten (10) days following discovery of such de-
fects by buyer, or within ten (10) days after such defects should reasonably have
been discovered, whichever is less;
b. the defective unit is returned to seller, transportation charges prepaid by buyer.
c. payment in full has been received by seller or said products; and
d. seller’s examination of such unit shall disclose to its satisfaction that such de-
fects have not been caused by misuse, neglect, improper installation, repair, alter-
ation, act of God, or accident.
No warranty made hereunder shall extend to any seller product whose serial num-
ber is altered, effaced or removed. Seller makes no warranty, express or implied,
with respect to motors, switches, controls, or other components of seller’s prod-
uct, where such components are warranted separately by their respective manu-
facturers. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WAR-
RANTIES, EXPRESS OR IMPLIED, WHETHER STATUTORY OR OTHERWISE,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. In no event shall seller be liable to buyer for
indirect, incidental collateral, or consequential damages of any kind. (BUYER’S
FAILURE TO PAY THE FULL AMOUNT DUE WITHIN SIXTY (60) DAYS OF DATE
OF INVOICE SHALL OPERATE TO RELEASE SELLER FROM ANY AND ALL
LIABILITY OR OBLIGATION ARISING PURSUANT TO ANY WARRANTY, EX-
PRESS OR IMPLIED, WHETHER STATUTORY OR OTHERWISE, INCLUDING
ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PAR-
TICULAR PURPOSE, MADE IN CONNECTION WITH ANY CONTRACT FORMED
HEREUNDER. BUYER AGREES THAT SUCH FAILURE TO PAY SHALL CON-
STITUTE A VOLUNTARY WAIVER OF ANY AND ALL SUCH WARRANTIES ARIS-
ING PURSUANT TO SUCH CONTACT.)

TWIN CITY FAN & BLOWER, 

5959 Trenton Lane, Minneapolis, MN 55442

MODEL  T080 

Summary of Contents for T080

Page 1: ...ioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities CEILING VENTILATOR READ AND SAVE THESE INSTRUCTIONS Installer Leave this manual with the homeowner Homeowner Use and Care information on page 4 WARNING 6 Ducted fans must always be vented to the outdoors 7 If this unit is to be installed...

Page 2: ...ick ceiling material Bend two tabs on side of housing 900 outward Lift housing until tabs contact underside of joist Mark the keyhole slot on both mounting brackets 3 Set housing aside and drive nails partially into joist at the top of both keyhole marks 4 Hang housing from nails and pound nails tight To ensure a noise free mount pound another nail through the top hole of each mounting tab New Con...

Page 3: ...ible to unit Do not allow cable to touch sides or top of unit after installation is complete 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive another nail through the top hole of each mounting bracket Existing Construction 5 Additional mounting holes are provided for installations...

Page 4: ... of seller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such de fects by buyer or within ten 10 days after such defects should reasonably have been discovered whicheve...