Operation manual M12i
10
4.4 Connection options
The M12i loudspeaker is equipped as standard with the i-series screw terminal.
As options there can be mounted a panel with cable gland (CG-option) or a panel with two
built-in speakON® jacks (SO-option).
Furthermore, a blind cover option is available.
All connection options are only available in black colour.
NOTE
More information about the different connection options can be found in the respective opera-
ting instructions in the download area on the homepage of TW AUDiO.
NOTE
4.3 Rotating the HF horn
With the factory default orientation of the M12i loudspeaker horn, the horizontal coverage is
90° and the vertical coverage is 60°. In some situations, it may be advantageous to change the
high frequency dispersion pattern. To adjust the dispersion pattern, the M12i loudspeaker’s
HF horn can be rotated. Proceed as follows:
1. Place the M12i loudspeaker on its back, with the speaker grille facing up. Make sure to
place the speaker on a clean, non-slippery surface.
2. To remove the front grill, a 3 mm Allen key is required. Loosen the two mounting screws at
the top and bottom of the speaker cabinet.
3. Loosen the four screws on the horn using a 3 mm Allen key. Pull the horn with the compres-
sion driver up and out of the speaker cabinet.
4. Check the seal between housing and horn for correct fit.
5. Carefully turn the horn by 90° and re-insert the horn with the driver back into the recess.
Screw it to the housing and apply medium-strength thread-locking fluid.
6. Attach the grill using the screws provided.
Summary of Contents for M12i
Page 1: ...Operation manual M12i...