TVT Digital TD-9524S1 Quick Start Manual Download Page 2

IE Network Connection

5

MENU

MENU

IPC

IPC

  Network  Cable

  Network  Cable

  Network  Cable

Switch

Router

Computer

Computer

● 

Access the camera through IP

-

Tool

 

Here we take accessing IP camera via LAN for example. In

 

LAN, 

there are two ways to access. 1. Access through  IP

-

Tool; 

2. Directly Access through IE Browser 

 

Make sure that the camera and the PC are well connected via LAN.

 Find the IP-Tool from the CD and then install it in the computer.

 After that, run the IP-Tool as shown below. 

Device

 

Network

 

Search

Immediate

 

Refresh

name

name

name

IPC

IPC

IPC

unknown

unknown

unknown

192.168.226.201

192.168.1.2

192.168.1.3

80

80

80

9008

9008

9008

255.255.

255.255.

255.255.

Modify Network Parameter

Mac Address

IP Address

Modify

CE :98 :23 :75 :35 :22

192

 .

168

 . 

226

 

. 201

255

 .

 255

 . 

255

 

.  0

192

 .

168

 . 

226

 

.  1

i

Tip: Enter the administrator password, and
then modify the network parameters.

Total Device: 3

Local IP Address:192

.

168

.

1

.

4

Subnet Mask:255

.

255

.

255

.

0 Gateway: 192

.

168

.

1

.

1

DNS

210

.

21

.

196

.

6

Device Name Device Type

IP Address

Http Port

Data Port

Subnet

Product Model

About

Subnet Mask

Gateway

Restore IPC Default Configuration

 Modify the IP address. The default IP address of this camera is 

192.168.226.201. Click the information of the camera listed in the

above table to show the network information on the right hand. 

Modify the IP address and gateway of the camera and make sure its 

network address is in the same local network segment as that of the

computer. Please modify the  IP address of your device according 

to the practical situation.   

Mac Address

IP Address

Modify Network Parameter

Modify

CE :98 :23 :75 :35 :22

192

 .

168

 . 

  1  

 

. 201

255

 .

 255

 . 

255

 

.  0

192

 .

168

 . 

  1  

 

.   1

Subnet Mask

Gateway

For example, the IP address of your computer is 192.168.1.4. So

 

the

IP address of the camera shall be changed to 192.168.1.X.  After 

modification, please input the password of the administrator and click

 “Modify” button to modify the setting.

            The default  password of the administrator  is  “

123456

”.

 

Double-click  the IP address  and then the system will pop up the IE 

browser to connect IP-CAM. After downloading Active X control, a 

login window will pop up. Input the user name and password to login.

    

  

● 

Directly Access Through IE

 

 

      

The default network settings are as shown below:

IP address: 192.168.226.201          HTTP:80

Subnet Mask: 255.255.255.0          Data Port:9008

Gateway: 192.168.226.1

You may use the above default settings when you log in the camera 

for the first time. 

 Set the IP address of the PC and make sure the network segment 

should be as the same as the default settings of IP-CAM. Open the 

network and share center. Click “Local Area Connection” to pop up

the following window. Select “Properties”  and then select Internet 

protocol according to the actual situation (for example: IPv4). 

Next, click “Properties” button to set the network of the PC. 

 

Open the IE browser and input the default address of IP-CAM

and confirm. The IE browser will download Active X control 

automatically.

 

After downloading Active X control, the login dialog box will

pop up.

 Input the default username and password and then enter to view.

450043000480 A0

  The default username is 

admin

; the default password is 

123456

.

 The installation is complete as shown below.

 

base to the ceiling or wall with screws.

 

then secure the mounting 

Route the cables and connect the cables. And 

 Adjust the camera to obtain an optimum angle. Then secure the camera

to the mounting base. 

Ceiling or Wall