SafeWare Program:

Each time the Windows 95 program is started , SafeWare for windows 95 will

automatically start and run unless the user deletes the SafeWare Icon from the Windows
95 Startup folder. By default, SafeWare will start in “Minimized” mode.

Once the SafeWare application has been closed, clicking on the SafeWare icon in

either the SafeWare folder or the Startup folder will once again start SafeWare.

Main SafeWare Screen

The safeWare screen makes a variety of AI-UPS status and control information available
to the user. The left portion of the SafeWare screen displays six large gauges that are
labeled:

Input Voltage

Output voltage

Input Frequency

Output Frequency

Battery Level

Load Level.

These gauges are similar in appearance to automative gauges and graphically indicate
the current values of the specific  labeled AI-UPS categories. A text box below each
gauge also shows the exact value or percentage of the specific category.

The top right hand portion of the SafeWare screen has indicators for the input power and
AI-UPS status. The indicators will turn on, off or flash to indicate the current input Power
and AI-UPS condition. they include:

Power Normal

Battery Low

UPS Fault

Power Failure

Battery  Weak

UPS Overload

Just below the Power and AI-UPS Status indicators is the Countdown Time display box.
This box will indicate the countdown time that has been entered by the user in the
SafeWare Settings. In case of a loss of utility power, the value in the box will decrease
until it reaches zero at which time SafeWare will cause the Windows 95 save/exit routine
to begin. At any time during the countdown, the user may click on the box to the left of
the Abort Countdown box at which time the countdown will resume, or 2) the AI-UPS
reaches a battery low condition. If a battery low condition occurs, SafeWare will override
the abort command and automatically run the Windows 95 safe/exit routine and cause
the computer system and AI-UPS to shutdown.
The lower right hand portion of the SafeWare screen displays the Waveform chart which
is a graphical waveform representation of the AI-UPS operational parameters. there are
three AI-UPS categories that can be displayed on the Waveform chart:Input/Output
Voltage Waveform, Input/Output Frequency Waveform, and Battery/Load Level Wave-
form. By clicking on the Toggle Waveform button user can display the different wave-
forms.

The Waveform chart displays information in a time based format. Time markings below
the chart will inform the user of the time that a power event occurred. Buttons to the right

Summary of Contents for Power UPS LITE 500VA

Page 1: ...EXHIBIT C User Manual...

Page 2: ...User Manual Power UPS 500 Page 1 USER MANUAL STARTUPS LITE 500 REV 1 0 UNINTERRUPTIBLE POWER SUPPLY...

Page 3: ...tronics Limited No 34 Developed plots South Phase Industrial Estate Guindy Chennai 600 032 Please note that it is mandatory to register your product with us The warranty applicable for this product is...

Page 4: ...purchaser What the warranty does not cover 1 Any product on which the serial number has been defaced modified or removed 2 Damage deterioration or malfunction resulting from a Accident misuse neglect...

Page 5: ...n and start up of the Power UPS 500 Please keep this manual in a safe place for future reference Contents 1 Introduction 6 2 Safety 7 3 Outlook And Function 8 4 Installation 11 5 Operation 12 6 Alarms...

Page 6: ...hat will make your equipment to operate more reliable The packing kit contains UPS Power UPS 500VA Output power cable and CD ROM Built in Automatic Voltage Regulator Provides regulated output voltage...

Page 7: ...cover no user serviceable parts inside Refer servicing to qualified service personnel CAUTION THIS EQUIPMENT MUST BE EARTHED AT ALL TIMES WHILST IN USE Replace batteries only with the same type and r...

Page 8: ...o p t u p t u O y t i c a p a c d e t a r e h t s o u n i t n o c d e R r e z z u B s o u n i t n o c t o N e l b i s s o p y r e t t a B t u p t u o g n i g r a h c N O d n a N O t u p t u o d n a s...

Page 9: ...s p e e B c e S t o N e l b i s s o p t s e t f l e S N O f o s s e r p s d n o c e s 2 r e t f A r e t r e v n i o t o g l l a h s t i n U h c t i w s e h t k c e h c o t c e S 6 r o f e t a t s k c...

Page 10: ...ower cable Resettable fuse Fuse thermal 5A UPS output with Power back up UPS output without Power back up DB 9 port LAN FAX MODEM surge protect StartUPS LITE Fuse used is a resettable 5A Reset the fus...

Page 11: ...e may be reduced 4 7 RJ 45 Connection Connect the telephone line to RJ 45 connector of UPS IN and UPS OUT RJ 45 is connected to the modem input It protects from Lightning surges CAUTION 1 The UPS outp...

Page 12: ...f the battery With the UPS plugged in to normal mains voltage activate the self test by pressing the ON button 5 5 Auto Voltage Regulation The UPS automatically corrects high and low utility voltages...

Page 13: ...rm in this way does not affect the computer interface alarm 6 2 Overload When the UPS is overloaded when the connected loads exceed maximum load the UPS gives a continuous audible alarm beep The alarm...

Page 14: ...r time 4msec typical Power factor 0 6 Battery type Maintenance free lead acid 12V 7Ah Recharge time 8 hours typical from total discharge UPS may be used immediately after discharge but will Provide sh...

Page 15: ...me run time in minutes as a function of load After End Autonomy automatic restart possible during 8 hours After 8 hours restart must be done manually press button ON s t t a W A V d a o L e m i t p u...

Page 16: ...n o c s i D w o n S P U e h t f I e c a f r e t n i e h t k c e h C y l l a m r o n s k r o w e h t d n a e l b a c e c a f r e t n i r e t u p m o c d e h e c a t t a n u r t t o n n a c S P U d n a...

Page 17: ...c e r t r o h s a g n i d n e s i e m i t e f i l s t i e h T y r e t t a b e h t e g r a h C s e r i u q e r y r e t t a b s S P U n a r e t f a g n i g r a h c e r s e i r e t t a B e g a t u o d e...

Page 18: ...n compared to a good battery Perform the following steps to make sure the battery needs replacing 1 make sure the UPS is plugged into a live wall outlet 2 charge the UPS for at least 8 hours 3 turn th...

Page 19: ...ut voltage 2 Mains Input frequency 3 UPS Output voltage 4 UPS Output frequency 5 UPS Load 6 Battery voltage 7 Backup time 8 Alarms In the event of batteries near exhaustion the UPS can send commands f...

Page 20: ...ormal Battery Low UPS Fault Power Failure Battery Weak UPS Overload Just below the Power and AI UPS Status indicators is the Countdown Time display box This box will indicate the countdown time that h...

Page 21: ...utton located under the Toggle Waveform button If the waveform information is recorded it is saved in a DAT file that can later be accessed and viewed using the SafeWare UPSWave program in the SafeWar...

Page 22: ...ny RS232 cable be connected A You are required to connect the TVS E supplied RS232 cable Q Can a laser printer be connected to the backed up socket A No You are required to coneected to the surge prot...

Page 23: ...ement of the product Wherein TVSE may use reconditioned parts units or new parts units We shall not be liable for 1 Damage to other products caused by any defects in the product damages based upon inc...

Page 24: ...TVS ELECTRONICS LIMITED Plot No 34 Developed plots South phase Industrial estate Guindy Chennai 600 032 Visit us at www tvse com...

Page 25: ...ot installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa...

Reviews: