User Manual Power UPS 500
Page 19
SafeWare Program:
Each time the Windows 95 program is started , SafeWare for windows 95 will
automatically start and run unless the user deletes the SafeWare Icon from the Windows
95 Startup folder. By default, SafeWare will start in “Minimized” mode.
Once the SafeWare application has been closed, clicking on the SafeWare icon in
either the SafeWare folder or the Startup folder will once again start SafeWare.
Main SafeWare Screen
The safeWare screen makes a variety of AI-UPS status and control information available
to the user. The left portion of the SafeWare screen displays six large gauges that are
labeled:
Input Voltage
Output voltage
Input Frequency
Output Frequency
Battery Level
Load Level.
These gauges are similar in appearance to automative gauges and graphically indicate
the current values of the specific labeled AI-UPS categories. A text box below each
gauge also shows the exact value or percentage of the specific category.
The top right hand portion of the SafeWare screen has indicators for the input power and
AI-UPS status. The indicators will turn on, off or flash to indicate the current input Power
and AI-UPS condition. they include:
Power Normal
Battery Low
UPS Fault
Power Failure
Battery Weak
UPS Overload
Just below the Power and AI-UPS Status indicators is the Countdown Time display box.
This box will indicate the countdown time that has been entered by the user in the
SafeWare Settings. In case of a loss of utility power, the value in the box will decrease
until it reaches zero at which time SafeWare will cause the Windows 95 save/exit routine
to begin. At any time during the countdown, the user may click on the box to the left of
the Abort Countdown box at which time the countdown will resume, or 2) the AI-UPS
reaches a battery low condition. If a battery low condition occurs, SafeWare will override
the abort command and automatically run the Windows 95 safe/exit routine and cause
the computer system and AI-UPS to shutdown.
The lower right hand portion of the SafeWare screen displays the Waveform chart which
is a graphical waveform representation of the AI-UPS operational parameters. there are
three AI-UPS categories that can be displayed on the Waveform chart:Input/Output
Voltage Waveform, Input/Output Frequency Waveform, and Battery/Load Level Wave-
form. By clicking on the Toggle Waveform button user can display the different wave-
forms.
The Waveform chart displays information in a time based format. Time markings below
the chart will inform the user of the time that a power event occurred. Buttons to the right