Tvone Magenta MultiView 2211045-02 Quick Start Manual Download Page 3

Mini Dense Pack Power Supply 

 

FCC and industry Canada radio frequency 
interference statements 

This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own 
expense. 
Modifications not expressly approved by the manufacturer could 
void the user’s authority to operate the equipment under FCC rules. 

Canada (ICES-003) notice:

  This Class A digital apparatus complies 

with Canadian ICES-003. (Cet appareil numerique de la classe A est 
conforme a la norme NMB-003 du Canada) 

European union declaration of conformity 

The manufacturer declares that this product meets the 
requirements of EU Directive 89/336/EEC for EMC and LVD safety for 
ITE 2006/95/EC.   
International customers AC mains cord supplied with unit must 
conform to IEC G0227 designation H03UVV-F or H03VVH2-F, 
conductors shall be at least .75mm2 cross-sectional area (18 AWG).

 

 

 

 

Summary of Contents for Magenta MultiView 2211045-02

Page 1: ... We Engineer Confidence We Engineer Confidence Copyright tvONE 2019 Mar 2019 2211045 02 MultiView Series Mini Dense Pack Power Supply Quick Start Guide ...

Page 2: ...C and industry Canada radio frequency interference statements 1 European union declaration of conformity 1 Specifications 2 Introduction 4 Setup and Installation 5 Troubleshooting 7 Appendix A Cabling Pinouts 8 Contact us 9 ...

Page 3: ...in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules Canada ICES 003 notice This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la classe...

Page 4: ... to 140 F 20 to 60 C Humidity tolerance Up to 80 non condensing Enclosure Powder Coated Steel Power 100 240 VAC 50 60Hz 1 5A max Consumption 150 Watts maximum Fuse There are two internal AC mains fuses These fuses are not user replaceable CAUTION DOUBLE POLE NEUTRAL FUSING Fuse rating 5x20mm 2A 250V Fuse type Littelfuse P N 0218002 HXP Output 5 Volts DC at 10 amps maximum 12 Volts DC at 4 2 Amps m...

Page 5: ...Mini Dense Pack Power Supply 3 Weight 3 Lbs 1 36 Kg Accessories 1U dual rack mount kit PN 400R3379 DC coaxial cable with tinned conductors PN 8450333 ...

Page 6: ...erve proper polarity when connecting devices Reversing polarities or connecting to the wrong voltage may damage the Mini Dense Pack and or the attached device Generally the positive conductor has a white line Always verify plus minus cable conductors before connection to the Mini Dense Pack Supplied Cabling The MultiView Series Mini Dense Pack is supplied with 6 six foot DC power cables for use wi...

Page 7: ...itive conductor has a white line Always verify plus minus cable conductors before connection to the Mini Dense Pack Total output power capacity is over 100 Watts and each port can provide power up to the following levels 12 Volts DC 700 mA 8 4W 5 Volts DC 1 67 A 8 35W Up to 100 watts of power can be supplied by any combination of ports so long as the maximum current rating for any given port is no...

Page 8: ...ting current limiting fuse Over current sensing will cause the fuse to open removing the port s load from the power supply Once over current situation is resolved the fuse once again will allow normal operation 5VDC 12VDC OBSERVE PROPER POLARITY AC IN Fault LED ON indicates overload Remove devices until LED goes OFF OK LED ON indicates normal operation 90 LED ON indicates unit is close to power ou...

Page 9: ...y be blown These are not user serviceable components Contact tvONE support for assistance Problem Powered Unit shuts off after period of time Solution Over current situation may be present causing DC port protection device to shut down port Check DC cable for shorts misconnections Problem Mini Dense Pack turned on but no or low voltage at outputs Solution x Check for unit load exceeding units maxi...

Page 10: ...8 tvONE Appendix A Cabling Pinouts Mini Dense Pack End Multiview Device End 2 5mm Center Positive 5 5mm Ring minus MultiView Device End ...

Page 11: ...s subject to change without notice No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or any means electronic or mechanical including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of tvONE Copyright 2019 tvONE All rights reserved Registered in the U S Patent and Trademark Office ...

Page 12: ...We Engineer Confidence We Engineer Confidence CAPTIVATE your AUDIENCE The best technology for creating eye catching visual experiences ...