MNL-1RK-SPDR-V1.0
3
Using the ONErack Spider PSU’s
Both models have Power Modules fitted, status LED’s and a power Meter. The power modules need to be
configured to the required voltage of your 3
rd
party equipment, and you can use the LED’s and Power Meter to
check the status, and diagnose faults as explained here.
Power Modules
To set the correct voltage output [shipping default voltage = 5V] and connect your device to the output of
the power module, you may need the following tools: -
Pozidriv® PZ1 crosshead screwdriver
2mm flat head screwdriver
Wire cutters
Wire strippers
Voltmeter
Setting the Output Voltage
1.
Unscrew and remove the module from the ONErack Spider PSU using the Module Extractor as shown.
2.
Turn the switch inside the module until the white dot points to the correct voltage for your device(s).
3.
Replace the Module back into the ONErack Spider PSU and tighten screw. Use one of the Voltage
stickers, apply to the end of the screw that holds the Power Module in place.