Installation Manual
PR166202

Copyright Tvilight B.V.  | PR 00-1662-02   |   Rev. D   |  24/01/2021

TVILIGHT PROJECTS BV / Beechavenue 162-180, 1119 PS, Schiphol-Rijk, the Netherlands

[email protected] / www.tvilight.com

Summary of Contents for OPENSKY Zhaga IoT

Page 1: ...ENSKY Zhaga IoT Installation Manual PR166202 Copyright Tvilight B V PR 00 1662 02 Rev D 24 01 2021 TVILIGHT PROJECTS BV Beechavenue 162 180 1119 PS Schiphol Rijk the Netherlands info tvilight com www tvilight com ...

Page 2: ...nction properly OPENSKY Zhaga IoT must be connected to a dimmable DALI driver ballast preferably D4I or SR compliant NOTE Some dimmable drivers ballasts must be programmed set to DALI mode Also select the correct configuration i e DALI from the CMS If this has not been done OPENSKY Zhaga IoT will not be able to dim the connected armature DALI logarithmic dimming mode is recommended ...

Page 3: ...device comes with two QR Code labels 1 Please stick one label on the street light luminaire 2 Please stick the second label on the street pole preferably inside the junction box QR Code needs to be scanned once using Tvilight Scan Go App please see the instructions below Input 18 30 Vdc Output 0 10V DALI SR D4I RF EGPRS LTE Cat M1 Cat NB2 ta 40 C 70 C 50 83 mm 15 87 mm Zhaga IoT 740215000AC ...

Page 4: ...tyManager 4 The Device Name OpenSky Zhaga IoT Serial Number QR Code UID and Com ments can be added manually 5 The Device Serial Number can also be added using the Scanner function which is activated by tapping the camera icon in the app 6 For more information on how to use Scan Go app please visit https www tvilight com scan go 7 To create your user account please email helpdesk tvilight com Pleas...

Page 5: ...ess OpenSky Zhaga IoT onto the Zhaga Receptacle and twist to lock in place 2 Connect OpenSky Zhaga IoT 1 Remove Sealing Cap from the Zhaga Receptacle NOTE The receptacle and threfore the OpenSky Zhaga must be mounted on the top side of the luminaire ...

Page 6: ...ole ID Labels match 3 Apply Pole ID Label to the pole Beechavenue 162 180 1119 PS Schiphol Rijk the Netherlands Designed in the Netherlands Assembled in PRC Input 18 30 Vdc Output 0 10V DALI SR D4I RF EGPRS LTE Cat M1 Cat NB2 ta 40 C 70 C Zhaga IoT 740215000AC 740215000AC 1 m ...

Page 7: ...ther of 500mm to mount the receptacle To provide a water tight mounting seal the luminaire surface must be free of dirt debris or burrs Sealing gasket provided with the receptacle assembly must be used Receptacle can be used on a luminaire housing thickness between 1 5mm to 6 0mm When mounting receptacle assembly it must not rotate during locking washer and locking nut application Torque mounting ...

Page 8: ...r to ensure they do not result in excessive movement of the receptacle assembly during mounting or use Excessive movement could result in reduced system performance An absolute maximum hole diameter of 22 0mm should be used The recommended mounting hole can be seen below Refer to product drawing for additional details A2 Mounting Hole Pattern ...

Page 9: ... 3 Positive pole for DALI or DALI based protocol 4 LSI sensor input The receptacle is wired on the bottom side of the assembly access from the inside of the luminaire Wire entry locations are labelled 1 2 3 and 4 Corresponding contact designations are marked the same on the module bases for PCB alignment A3 Wire Locations Please ensure to connect the DALI and DALI wires correctly DALI is shared wi...

Page 10: ...Wire Acceptable only if tin dipped Solid Wire Acceptable Not Acceptable Insulation Conductor Strip Length Strip Length Bent Stripped Wire Burr at Cutoff Extreme Chisel Tip Not Cut 90 Misaligned Cutter Tips Poorly Prepared Insulation NOTE Recommended maximum insulation diameter should be as provided in Figure 5 Wires with larger insulation diameters will not fit within the housing s poke in hole in...

Page 11: ... cross section and 16 0mm long insert it into the window one per wire and open the contact beams The wire may then be extracted from the connector along the axis of wire insertion direction A5 Wire Termination Stripped wire inserted into housing Insulation inside housing Release tool window Release tool fully inserted Wire can be retracted from housing Release tool DANGER Extreme caution to ensure...

Page 12: ...and the OLC location So please have patience 6 The device should now be online on CMS and the green LED will turn to solid green The device should now be online on CMS 7 Use your login same as Scan Go app or other user account provided by Tvilight Support Desk to login to the CityManager CMS https tvilight io 8 You are ready and connected Enjoy energy savings and smart maintenance notifications LE...

Page 13: ...location Please note that the sim connection can take as much as 8 hours when used for the first time in your region 3 If the above steps did not resolve the issue then please contact Tvilight support desk helpdesk tvilight com 3 Tried everything faulty device We are very sorry Please contact support tvilight com for further instructions and send the device for RMA replacement Further support We a...