TVILIGHT CitySense Plus Installation Manual Download Page 9

Page 9 of 10

Wiring Diagram

WARNING:

 

If not correctly connected product might not 

function or it might be permanently damaged.  

DC +

Connector

(e.g. Wago)

AC in(N)

AC in(L)

DC -

L

N

Junction Box

GND

GND

N

L

L out

N out

DC-

DC+

GREEN

BROWN

WHITE

BLACK

GREY

BLUE

RED

Summary of Contents for CitySense Plus

Page 1: ...CitySense Plus Installation Manual Cable Gland English ...

Page 2: ...or Date Changes Approved by v4 Henri Eskonen 21 12 2017 Added version control page Minor formatting v4 21 12 2017 TVILIGHT BV Westerhaven 13 9718 AW Groningen the Netherlands 31 0 50 800 3240 info tvilight com www tvilight com ...

Page 3: ...erly CitySense Plus must be connected to a dimmable driver ballast NOTE Some dimmable drivers ballasts must be programmed set to dimmable mode If this has not been done CitySense Plus will not be able to dim the connected armature ATTENTION ...

Page 4: ...Page 4 of 10 In box 5m Cable M16 Cable Gland Sticker Generic Strap x 2 You ll need Max 11mm Min 8mm M16 Thread Drill Wago x 4 TVILIGHT www tvilight com TVI CSP1 01 0014 ...

Page 5: ... of 10 1 Push cable gland through wire 2 Drill M16 threaded hole into pole 5m Note for added protection against rust the use of an anti corrosion spray such as WD40 Corrosion inhibitor or equal is recommended ...

Page 6: ...Page 6 of 10 3 Run wire through hole 4 Screw cable gland in hole Rotate the cable gland to tighten Twist the end leads of the wires ...

Page 7: ...Page 7 of 10 5 Strap product to pole 6 Level the product Ensure Tensioning Tool is set to maximum tension 4 Tensioning Tool Position 2 Standard 1 2 3 ...

Page 8: ...Page 8 of 10 SAME TVILIGHT www tvilight com TVI CSP1 01 0014 TVILIGHT www tvilight com TVI CSP1 01 0014 TVILIGHT www tvilight com TVI CSP1 01 0014 7 Apply product ID sticker to pole 2 m ...

Page 9: ...ram WARNING If not correctly connected product might not function or it might be permanently damaged DC Connector e g Wago AC in N AC in L DC L N Junction Box GND GND N L L out N out DC DC GREEN BROWN WHITE BLACK GREY BLUE RED ...

Page 10: ...LACK GREY BLUE RED N L Lout Nout 1 10V or DALI 1 10V or DALI Wiring Diagram WARNING If not correctly connected product might not function or it might be permanently damaged Note For added protection it is recommenteded to add an external circuit breaker at the power input of the product Circuit breakers such as the ELeQ LS 94 5L2408 or similar rated products could be used ...

Page 11: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 meters Tilt 0 degrees 2 m 7 5 m 2 m 0 5 m 7 m 3 2 m 13 5 m 4 5 m ...

Page 12: ...2 7 m 10 65 m 2 42m 4 16 m 2 25 m 3 7 m 1 1 m 2 2 m 9 4 m 14 8 m 14 m 5 3 m 4 9 m CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 meters Tilt 7 5 degrees ...

Page 13: ...12 8 m 12 8 m 5 2 m 4 1 m 5 6 m 2 1m 5 2 m 1 m 2 42m 4 16 m 2 25 m CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 meters Tilt 7 5 degrees ...

Page 14: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 5 meters Tilt 0 degrees 8 5 m 2 25 m 3 6 m 2 m 0 6 m 15 m 5 m 7 7 m ...

Page 15: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 5 meters Tilt 7 5 degrees 12 1 m 3 m 4 7 m 2 7 m 2 25 m 4 1 m 1 2 m 2 5 m 10 5 m 16 7 m 15 8 m 6 m 5 5 m ...

Page 16: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 4 5 meters Tilt 7 5 degrees 4 6 m 6 3 m 2 4 m 1 1 m 6 m 5 8 m 10 5 m 14 3 m 2 7 m 4 7 m 2 25 m ...

Page 17: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 meters Tilt 0 degrees 2 5 m 9 5 m 2 5 m 4 m 16 5 m 5 5 m 0 7 m 8 5 m ...

Page 18: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 meters Tilt 7 5 degrees 5 2 m 3 m 13 5 m 3 4 m 2 75 m 18 5 m 17 5 m 6 6 m 6 1 m 4 6 m 1 4 m 2 8 m 11 7 m ...

Page 19: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 meters Tilt 7 5 degrees 7 m 2 6 m 1 3 m 6 5 m 15 9 m 11 8 m 6 4 m 5 1 m 5 2 m 3 m 2 45 m ...

Page 20: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 5 meters Tilt 0 degrees 10 5 m 2 75 m 2 75 m 4 4 m 16 5 m 5 5 m 0 7 m 9 3 m ...

Page 21: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 5 meters Tilt 7 5 degrees 2 75 m 5 7 m 14 9 m 3 7 m 3 4 m 20 m 19 3 m 7 3 m 6 7 m 5 m 1 5 m 3 m 12 8 m ...

Page 22: ...CitySense Plus Indicative Sensor Detection Zones Mounting Height 5 5 meters Tilt 7 5 degrees 7 7 m 2 9 m 1 4 m 7 1 m 17 5 m 13 m 7 1 m 5 6 m 2 72 m 5 7 m 3 4 m ...

Reviews: