background image

2.0 

IMPORTANT SAFETY INSTRUCTIONS 

 
To insure the best from this product, please read this manual carefully.  Keep it in a safe 
place for future reference. 
 
To reduce the risk of electric shock, do not remove the cover from the unit. 
No user serviceable parts inside.  Refer servicing to qualified personnel. 
 

2.1 

POWER AND CONNECTIONS  

 
This unit is not disconnected from the AC power source as long as it is connected to the 
wall outlet.  The off state for this unit is called standby mode.  In standby mode the unit 
is designed to consume a reduced quantity of power compared to normal operating 
modes. 
 
When not using the unit for a long period of time, insure that the AC power cord is 
disconnected from the wall outlet. 
 
The AC wall outlet should be installed near to the unit and be easily accessible. 
 
Do not plug in or attempt to operate an obviously damaged unit. 
 

2.2 

WATER AND MOISTURE  

 
To reduce the risk of fire, do not expose the unit to rain, water or excessive moisture. 
 

2.3 GENERAL 

CARE 

 
Do not force switches or external connections.   
 
When moving the unit, disconnect the serial port connections first then the power cable 
and finally the interconnecting cables to other devices. 
 
Do not attempt to clean the unit with chemical solvents or aerosol cleaners, as this may 
damage the unit.  Use a clean dry cloth. 
 

2.4 LOCATION 

 

 
Installation of this unit should be in a cool dry place, away from sources of excessive 
heat, vibration, dust, moisture and cold. 
 

2.5 VENTILATION 

 

 
Slots and openings in the sides of the unit are provided for ventilation.  To insure 
reliable operation, avoid obstruction of these openings and insure the unit is installed in 
a well-ventilated area. 

 

5

Summary of Contents for DV-1394 Pro-SDI

Page 1: ...Instruction Manual DV 1394 Pro SDI Analog Converter...

Page 2: ...2...

Page 3: ...i Language Safety and IPR Information 5 4 0 Specifications 15 5 0 Package Contents 16 6 0 Connecting the Hardware 17 7 0 Operating The Unit 18 8 0 Troubleshooting 30 9 0 Limited Warranty 31 10 0 Regul...

Page 4: ...any form or means electronic or mechanical including photocopying recording or by any information storage or retrieval system without the written consent of the publisher TV ONE reserves the right to...

Page 5: ...t should be installed near to the unit and be easily accessible Do not plug in or attempt to operate an obviously damaged unit 2 2 WATER AND MOISTURE To reduce the risk of fire do not expose the unit...

Page 6: ...ROPERTY Some IC chips in this product include confidential and or trade secret property Therefore you may not copy modify adapt translate distribute reverse engineer reverse assemble or decompile the...

Page 7: ...assurez vous que le c ble d alimentation lectrique est d connect de la prise murale La prise murale de courant doit tre install e pr s de l unit et ais ment accessible Ne branchez pas et n essayez pa...

Page 8: ...ouvertures et assurez vous que l unit est install e dans un endroit bien a r 3 0 PROPRIETE INTELLECTUELLE Certaines puces IC dans ce produit contiennent des l ments propri taires confidentiels et ou d...

Page 9: ...el cable de corriente CA de la toma de la pared cuando no va a utilizar el aparato por un periodo largo de tiempo La toma CA de la pared ha de estar instalada cerca del aparato y debe ser f cilmente...

Page 10: ...y tambi n asegurar que el aparato se instale en una zona con adecuada ventilaci n 3 0 PROPIEDAD INTELECTUAL Algunos chips con circuito integrado de este producto incluyen propiedad confidencial y o pr...

Page 11: ...t ziehen Sie bitte das Stromkabel aus der Steckdose Die Steckdose sollte sich in der N he des Ger ts befinden und leicht zug nglich sein Verbinden Sie ein offensichtlich besch digtes Ger t keinesfalls...

Page 12: ...Sorgen Sie au erdem daf r dass das Ger t an einem gut bel fteten Ort aufgestellt wird 3 0 GEWERBLICHES EIGENTUM Einige integrierte Schaltkreise in diesem Produkt enthalten vertrauliche Informationen...

Page 13: ...kt zorg er dan voor dat de stekker van het wisselstroomsnoer uit het stopcontact is getrokken Het wisselstroom stopcontact moet dichtbij de eenheid ge nstalleerd worden en makkelijk toegankelijk zijn...

Page 14: ...eid op een goed geventileerde plek ge nstalleerd wordt zodat deze betrouwbaar werkt 3 0 INTELLECTUEEL EIGENDOM Sommige IC chips in dit product bevatten vertrouwelijke informatie en of fabrieksgeheimen...

Page 15: ...Control Front Panel Buttons LCD Display Unit Remote Control RS 232 via DB 9 Male Connector Machine Control DV RS 422 via DB 9 Male Connector Sampling Format DV DVCAM NTSC 4 1 1 PAL 4 2 0 DVC Pro NTSC...

Page 16: ...Cable 6 BNC to BNC 1x S Video Cable 6 4 Pin SV to 4 Pin SV 1x Firewire Cable 6 4 Pin DV to 6 Pin DV 1x Stereo Audio 6 RCA to RCA R L 1x Rackmount Kit Ears and Hardware 1xAC Power Cord 6 USA type 3 Pin...

Page 17: ...onnectors Unbalanced Stereo Audio Output RCA Connectors Composite Video CVBS In Output BNC Connectors S Video Y C In Output 5 Pin Mini DIN Connectors DV DVCAM In Output 6 Pin IEEE 1394 Connector DV 13...

Page 18: ...evant menu and press the or button to change the value The DV 1394 Pro SDI will store the last settings and use those if you turn it on again The Display shows the Menu Caption on the 1st line and the...

Page 19: ...o SDI with your PC As soon as you have established the connection between the DV 1394 Pro SDI and your PC s IEEE 1394 Interface and both PC and DV 1394 Pro SDI are powered on the Windows PC should rec...

Page 20: ...scode Video signals from a Betacam or other VTR to a DV VTR or vice versa it does not matter which version you are using You can switch the video system in the Menu see Menu Structure If you work with...

Page 21: ...The number on the left is for the DV 1394 Pro SDI connector and the number on the right is for the VTR s connector 7 6 Supported TC Formats DV1394Pro SDI MKII tries all the time to read Timecode from...

Page 22: ...us The batch digitizing does not function with Ulead software however simple control commands are possible The time code which is inserted in the DV data stream and can be read via the editing softwar...

Page 23: ...unction The User Interface in build in Tabs The first Tab is for the selection and adjustment the Video Inputs Video Level etc To adjust a Video Level hold the Mouse Button on the Slider and move it T...

Page 24: ...Format settings Please note that the DVC Pro only works in the decoding Mode e g Deck to SDI The fourth Tab shows the Misc Settings This is where you would select a COM Port for communication between...

Page 25: ...The fifth Tab shows Upgrade Section of the Control Software If you are unsure of your current firmware version status versus the latest available version contact your dealer or TV One 25...

Page 26: ...in Also a firmware upgrade via RS232 won t change these settings Values in this doc are given decimal Hex values are shown as 0xAA or similar 7 8 1 Data format Transmitting data to the DV1394Pro SDI T...

Page 27: ...oup 3 command byte command code 4 data bytes value return value 6 checksum command group byte command byte data bytes The checksum is simply added the bytes Overflow or carry bits are ignored since it...

Page 28: ...Range return value 0x81 default value 0x01 Brightness 0 256 0 256 128 0x02 Contrast 0 128 0 128 68 0x03 Saturation 0 128 0 128 64 0x04 Hue 0 256 0 256 0 0x05 Sharpness 7 7 0x0f 7 0x00 0 0x07 7 MSb fro...

Page 29: ...If no return value is given it returns the value written 29...

Page 30: ...EBU 0 2 0 0x02 analog Audio out level dB 0 63 0 63 0 0x08 Samplerate 0 1 0 32kHz 12bit 1 48kHz 16bit 0 1 0 0x09 Channel selection 32kHz 12bit Decoding 0 1 0 A 1 B 0 1 0 7 8 5 DV Format The command gro...

Page 31: ...ect or poor quality cables incorrect mode settings for the desired signal attempting to use both the front and rear Firewire connection at the same time only one may be used at a time or inadequate AC...

Page 32: ...orization Number from TV One and return the product to a location designated by TV One freight prepaid After repairs are complete the product will be returned freight prepaid LIMITATIONS All products...

Page 33: ...tvone co uk TV One Latin America 2790 NW 79 Ave Miami FL 33122 USA Tel 305 418 9305 Fax 305 418 3096 sales latinoamerica tvone com www tvonela com TV One Mercosur Honduras 5849 2nd Floor Office C C141...

Page 34: ...Notes 34...

Page 35: ...Notes 35...

Page 36: ...5 Fax 305 418 3096 sales latinoamerica tvone com www tvonela com TV One Mercosur Honduras 5849 2nd Floor Office C C1414BNI Capital Federal Buenos Aires Argentina Tel 54 11 4771 5570 Fax 54 11 4771 557...

Reviews: