background image

                                                                                                                 

TCLWRQS1 Datasheet

 

Hangzhou Tuya Information Technology Co., Ltd.  13 

V2.0.0 

environment. This equipment should be installed and operated with minimum distance 20cm between the 

radiator and your body. 

Important Note 

This radio module must not installed to co-locate and operating simultaneously with other radios in host 

system except in accordance with FCC multi-transmitter product procedures. Additional testing and 

equipment authorization may be required to operating simultaneously with other radio. 

The availability of some specific channels and/or operational frequency bands are country dependent 

and are firmware programmed at the factory to match the intended destination. The firmware setting is 

not accessible by the end user. 

The host product manufacturer is responsible for compliance to any other FCC rules that apply to the 

host not covered by the modular transmitter grant of certification. The final host product still requires Part 

15 Subpart B compliance testing with the modular transmitter installed.   

The end user manual shall include all required regulatory information/warning as shown in this manual, 

including: This product must be installed and operated with a minimum distance of 20 cm between the 

radiator and user body.   

This device have got a FCC ID

2ANDL-TCLWRQS1.The final end product must be labeled in a visible 

area with the following: 

Contains Transmitter Module FCC ID:2ANDL-TCLWRQS1

   

This device is intended only for OEM integrators under the following conditions:   

1)The antenna must be installed such that 20cm is maintained between the antenna and users, and 

2) The transmitter module may not be co-located with any other transmitter or antenna. 

As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM 

integrator is still responsible for testing their end-product for any additional compliance requirements 

required with this module installed. 

 

Declaration of Conformity European notice 

 

 

 

Hereby, Hangzhou Tuya Information Technology Co., Ltd declares that this module 

product is in compliance with essential requirements and other relevant provisions 

of Directive 2014/53/EU,2011/65/EU.A copy of the Declaration of conformity can be 

found at https://www.tuya.com 

Hereby, Hangzhou Tuya Information Technology Co., Ltd declares that this module 

product is in compliance with essential requirements and other relevant provisions 

of Directive 2014/53/EU,2011/65/EU.A copy of the Declaration of conformity can be 

found at https://www.tuya.com

 

Summary of Contents for TCLWRQS1

Page 1: ...N MAC 1T1R WLAN and rich peripheral resources 1 1 Features Embedded with32 bit CPU which can be used as an application processor Dominant frequency up to 125 MHz Working voltage 5 V Peripherals 1 UART...

Page 2: ...on Technology Co Ltd 2 V2 0 0 1 2 Applications Intelligent building Smart household and home appliances Industrial wireless control Handheld device Change History No Date Change Description Version Af...

Page 3: ...Parameters 7 3 2 Electrical Conditions 7 3 3 RF Current 8 3 5 Working Mode Current Consumptions 8 4 RF Features 9 4 1 Basic RF Features 9 4 2 Wi Fi Output Power 9 4 3 Wi Fi RX Sensitivity 10 5 Antenna...

Page 4: ...pins 6 Table 2 TCLWRQS1 test pins 6 Table 3 Absolute electrical parameters 7 Table 4 Normal electrical conditions 7 Table 5 Current during constant transmission and transmitting 8 Table 6 RX power con...

Page 5: ...mensions and Footprint TCLWRQS1 dimensions 49 3mm 0 35mm L 30 8 0 35mm W 7 8 0 15mm H Note H is the total height of Bottom surface components and Top surface components of the transfer plate Figure 1...

Page 6: ...te P indicates power supply pins I O indicates input and output pins 2 3 Test Pin Definition Table 2 describes the test pins Table 2 TCLWRQS1 test pins No Symbol I O Type Function 1 3 3V P Internal 3...

Page 7: ...voltage human body model Tamb 25 C N A 2 kV Static electricity voltage machine model Tamb 25 C N A 0 5 kV 3 2 Electrical Conditions Table 4 Normal electrical conditions Parameter Description Minimum V...

Page 8: ...wer consumption during constant receiving Symbol Mode Rate Typical Value Unit IRF CPU Sleep 11 Mbit s 90 mA IRF CPU Active 54 Mbit s 120 mA 3 5 Working Mode Current Consumptions Table 7 Working curren...

Page 9: ...or 11 Mbit s 802 11g 6 9 12 18 24 36 48 or 54 Mbit s 802 11n HT20 MCS0 to MCS7 802 11n HT40 MCS0 to MCS7 Antenna type Onboard PCB antenna 4 2 Wi Fi Output Power Table 9 TX power during constant emiss...

Page 10: ...mode MCS7 N A 70 N A dBm 5 Antenna Information 5 1 Antenna Type TCLWRQS1 uses the onboard PCB antenna 5 2 Antenna Interference Reduction To ensure optimal Wi Fi performance when the Wi Fi module uses...

Page 11: ...or a delivered module are as follows 1 The moisture proof bag is placed in an environment where the temperature is below 30 C and the relative humidity is lower than 70 2 The shelf life of a dry packa...

Page 12: ...ion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Howeve...

Page 13: ...installed and operated with a minimum distance of 20 cm between the radiator and user body This device have got a FCC ID 2ANDL TCLWRQS1 The final end product must be labeled in a visible area with the...

Page 14: ...This product must not be disposed of as normal household waste in accordance with EU directive for waste electrical and electronic equipment WEEE 2012 19 EU Instead it should be disposed of by return...

Reviews: