5.  To exit enrollment mode, press the siren button (indicator turns off).  

If the indicator fails to flash after the two reset beeps, it means that the siren is 
within radio range of the control panel to which it has been previously enrolled. 
In such a case, all devices previously enrolled to the siren have been deleted 
except for the control panel. If you deliberately do not want to use the siren with 
the control panel  anymore, it must first be deleted in the control panel  before 
resetting the siren (in control panel enrollment mode select the siren’s address 
and press and hold key 2 on the system keypad to delete the siren). 

 

Indicator functions 

In  normal  use,  the  indicator  flashes  when  the  doorbell  button  is  pressed  or 

when the siren sounds. If the siren is enrolled to an OASiS control panel, then it 
indicates the status of the programmable output PGY with a continuous light. 
The indicator flashes in enrollment mode.

 

Technical specifications 

Power supply 

230V/50Hz, 1W, class protection II  

Communication band 

868 MHz, OASiS protocol  

Communication range 

approx. 100 m (open area) 

Sounds (melodies) 

8 selectable for buttons and detectors,  

 

and an alarm siren sound 95 dB / 1 m 

Max. number of enrolled devices         

1x OASiS JA-80 control panel 

 

8x OASiS wireless buttons and detectors  

Safety class 

II according to EN60950 

Operating environment 

general, indoor 

–10 to +40 °C 

Housing 

IP40 according to EN 60529 

Mechanical immunity 

IK08 according to EN 50102 

Operating conditions                      

ERC REC 70-03  

The JA-80L complies with ETSI EN 300220, EN 50130-4, EN 55022  and EN 60950-1 

 

 