WARNING
WARNING
THE PUMP SHOULD NOT BE RUN DRY
. If after approximately 60 seconds there is no
discharge of liquid, stop the pump and investigate the possible cause.
Failure to comply with this could cause severe damage to internal seals, bushings and/or metal
parts.
Pump Performance Data
Size Capacity
(GPM)
Size Capacity
(GPM)
1C 3
CC009
9
2C 8
CC015
15
3C 17 CC020
20
4C 36 CC030
30
5C 61
6C 84
Based on pumping a fluid of 200
SSU viscosity at 50 psi and 1750
rpm
Based on pumping a fluid of 100
SSU viscosity at 50 psi and 1750
rpm
WARNING
WARNING
Failure to follow these instructions could result in serious bodily injury or death.
Do not attempt to work on any Tuthill pump installation before completing the steps below.
Disconnect the drive so that it cannot be started while work is being performed.
Review the Material Safety Data Sheet (MSDS) applicable to the liquid being pumped to
determine its characteristics and the precautions necessary to ensure safe handling.
Vent all pressure within the pump through the suction or discharge lines.
All Tuthill pumps contain residual 200 SSU lube oil from the factory production test. Determine
if this is compatible with the fluid you are pumping. If the fluid is incompatible, consult the
factory.
v 1.1.2
Page 7 of 16
6.13.05